4 research outputs found
Theoretical and experimental studies of the opto-electronic properties of positively charged oligo(phenylene vinylene)s: Effects of chain length and alkoxy substitution
In this paper a combined experimental and quantum chemical study of the geometry and opto-electronic properties of unsubstituted and dialkoxy-sustituted phenylene–vinylene oligomers (PV’s) is presented. The optical absorption spectra for PV cations with different chain lengths and substitution patterns were measured using pulse radiolysis with time-resolved spectrophotometric detection from 1380 to 500 nm (0.9 to 2.5 eV). The geometries of the PV’s studied were optimized using density functional theory (DFT) for both the neutral and singly charged molecule. The spectra for the PV radical cations were then calculated using singly excited configuration interaction with an intermediate neglect of differential overlap reference wave function method together with the DFT geometry. The agreement between experimental and theoretical absorption energies is excellent; most of the calculated radical cation absorption energies are within 0.15 eV of the experimental values. The pattern of dialkoxy-substitution is found to have a large effect on the optical absorption spectrum of the cation. Using the calculated charge distribution it is shown that the degree of delocalization of the charge correlates with the energy of the lowest absorption band. If alkoxy side chains are present on some of the rings the positive charge tends to localize at those sites.DelftChemTechApplied Science
Increasing the Astrophysical Reach of the Advanced Virgo Detector via the Application of Squeezed Vacuum States of Light
Current interferometric gravitational-wave detectors are limited by quantum noise over a wide range of their measurement bandwidth. One method to overcome the quantum limit is the injection of squeezed vacuum states of light into the interferometer’s dark port. Here, we report on the successful application of this quantum technology to improve the shot noise limited sensitivity of the Advanced Virgo gravitational-wave detector. A sensitivity enhancement of up to 3.2±0.1 dB beyond the shot noise limit is achieved. This nonclassical improvement corresponds to a 5%–8% increase of the binary neutron star horizon. The squeezing injection was fully automated and over the first 5 months of the third joint LIGO-Virgo observation run O3 squeezing was applied for more than 99% of the science time. During this period several gravitational-wave candidates have been recorded
Calibration of advanced Virgo and reconstruction of the detector strain h(t) during the observing run O3
International audienceThe three advanced Virgo and LIGO gravitational wave detectors participated to the third observing run (O3) between 1 April 2019 15:00 UTC and 27 March 2020 17:00 UTC, leading to several gravitational wave detections per month. This paper describes the advanced Virgo detector calibration and the reconstruction of the detector strain h(t) during O3, as well as the estimation of the associated uncertainties. For the first time, the photon calibration technique as been used as reference for Virgo calibration, which allowed to cross-calibrate the strain amplitude of the Virgo and LIGO detectors. The previous reference, so-called free swinging Michelson technique, has still been used but as an independent cross-check. h(t) reconstruction and noise subtraction were processed online, with good enough quality to prevent the need for offline reprocessing, except for the two last weeks of September 2019. The uncertainties for the reconstructed h(t) strain, estimated in this paper in a 20–2000 Hz frequency band, are frequency independent: 5% in amplitude, 35 mrad in phase and 10 μs in timing, with the exception of larger uncertainties around 50 Hz
