    The impact of different cooling strategies on urban air temperatures: the cases of Campinas, Brazil and Mendoza, Argentina

    Get PDF
    This paper describes different ways of reducing urban air temperature and their results in two cities: Campinas - Brazil- a warm temperate climate with a dry winter and hot summer (CWa), and Mendoza- Argentina -a desert climate with cold steppe (BWk)-. A high-resolution microclimate modeling system -ENVI-met 3.1- was used to evaluate the thermal performance of an urban canyon in each city. A total of 18 scenarios were simulated including changes in the surface albedo, vegetation percentage and the H/W aspect ratio of the urban canyons. These results revealed the same trend in behavior for each of the combinations of strategies evaluated in both cities. Nevertheless, these strategies produce a greater temperature reduction in the warm temperate climate (CWa). Increasing the vegetation percentage reduces air temperatures and mean radiant temperatures in all scenarios. In addition, there is a greater decrease of urban temperature with the vegetation increase when the H/W aspect is lower. Also, applying low albedo on vertical surfaces and high albedo on horizontal surfaces is successful in reducing air temperatures without raising mean radiant temperature. The best combination of strategies - 60% of vegetation, low albedos on walls and high albedos on pavements and roofs and 1.5 H/W- could reduce air temperatures up to 6.4 ºC in Campinas and 3.5 ºC in Mendoza.Fil: Alchapar, Noelia Liliana. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Mendoza. Instituto de Ambiente, Hábitat y Energía; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Mendoza. Instituto de Ciencias Humanas, Sociales y Ambientales; ArgentinaFil: Cotrim Pezzuto, Claudia. Pontifícia Universidade Católica de Campinas; BrasilFil: Correa Cantaloube, Erica Norma. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Mendoza. Instituto de Ciencias Humanas, Sociales y Ambientales; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Mendoza. Instituto de Ambiente, Hábitat y Energía; ArgentinaFil: Labaki, Lucila Chebel. Universidade Estadual de Campinas; Brasi

    Indicadores para o verde urbano (IVU): proposta de uma implementação computacional para indicadores de densidade vegetada e densidade construída

    No full text
    Urban density, which covers the population and construction spheres, is considered a fundamental parameter for understanding land use and occupation. In view of the current situation of the population densification process in urban centers, measuring it becomes indispensable with regard to its influence on the climatic scale and environmental quality of cities. In parallel, urban vegetation coverage is considered an essential element in the environmental and biophilic balance in the urban space, however the areas destined to these areas have suffered a progressive reduction in priority as well as in volume, both in consolidated areas and in areas of urban expansion, highlighting the need to reinforce / recreate tools aimed at regulating this parameter in urban legislation. In view of this, this work proposes a system of tools called Indicators for Urban Green (IUG), which is defined as the computational implementation composed of two proportion indicators that, through an algorithmic-parametric approach, allows establishing the existing correlation between the parameters of built density and vegetated density. The IUG consists of the Vegetable Density Indicator by Total Area (IDVAT) and the Vegetable Density Indicator by Constructed Density (IDVDC) formulated so that they can accurately measure the focus parameters of this research. To validate the proposed system, the IUG was applied in hypothetical (internal validation) and real (external validation) tests, the latter being carried out with the object of the Altiplano Cabo Branco neighborhood (João Pessoa - PB - Brazil). In the four hypothetical samples, four subtests were generated in different situations of vegetated areas for a comparative graphic understanding of the values found (diagram IUG). Then, in real sampling, the selected urban area was divided into six sub-areas that present different forms of building density and different types of vegetation cover. The indicators found in the real (current) scenario were: Altiplano 1: IDVAT = 0.06 / IDVDC = 0.4; Altiplano 2: IDVAT = 0.03 / IDVDC = 0.13; Altiplano 3: IDVAT = 0.05 / IDVDC = 0.19; Altiplano 4: IDVAT = 0.13 / IDVDC = 1.59; Altiplano 5: IDVAT = 0.11 / IDVDC = 0.92; Altiplano 6: IDVAT = 0.14 / IDVDC = 0.92. Then, two real-life scenarios of the neighborhood were chosen for the analysis of the trend scenarios and the construction of possible alternatives, in order to understand the values of the indicators in a situation of minimum proportion of vegetation cover with medium to large tree predominance. And, finally, a brief correlation of the indicators found was made with microclimate data from the city of João Pessoa (Ribeiro, 2013) that helped to visualize the relationship between the indicators with lower values and the areas with higher temperatures and devoid of vegetated density. Finally, it is expected that the evolution of the Indicators for Urban Green (IUG) can help provide data of fundamental importance to achieve greater levels of easing the climatic rigor through the minimum proportion between the vegetated and built volumes allocated in the urban space , as well as contributing to impact studies to avoid conflicts in the urbanization process and to promote the implementation of more equitable and environmentally qualified measures.Pró-Reitoria de Pós-graduação da UFPB (PRPG/UFPB)A densidade urbana, que abrange as esferas populacional e construtiva, é considerada um parâmetro fundamental para compreensão do uso e ocupação do solo. Diante do quadro atual do processo de adensamento populacional dos núcleos urbanos, mensurá-la tornase indispensável no que tange a sua influência na escala climática e qualidade ambiental das cidades. Em paralelo, considera-se a cobertura vegetal urbana como um elemento essencial no equilíbrio ambiental e biofílico no espaço urbano, entretanto as áreas destinadas a essas têm sofrido com uma redução progressiva de prioridade bem como de volume, tanto em áreas consolidadas como em zonas de expansão urbana, evidenciando a necessidade de se reforçar/recriar ferramentas voltadas para a regulação deste parâmetro na legislação urbana. Diante disso, este trabalho propõe um sistema de ferramentas denominado como Indicadores para o Verde Urbano (IVU), que se define como a implementação computacional composta por dois indicadores de proporção que, por meio de uma abordagem algorítmico-paramétrica, permite estabelecer a correlação existente entre os parâmetros de densidade construída e densidade vegetada. O IVU é composto pelo Indicador de Densidade Vegetal por Área Total (IDVAT) e o Indicador de Densidade Vegetada por Densidade Construída (IDVDC) formulados para que possam mensurar com precisão os parâmetros de enfoque desta pesquisa. Para validar o sistema proposto, aplicou-se o IVU em testes hipotéticos (validação interna) e reais (validação externa), sendo estes últimos realizados tendo como objeto o bairro Altiplano Cabo Branco (João Pessoa – PB – Brasil). Nas quatro amostragens hipotéticas, gerou-se quatro subtestes em situações diferentes de áreas vegetadas para compreensão gráfica comparativa dos valores encontrados (diagrama IVU). Em seguida, nas amostragens reais, dividiu-se o recorte urbano selecionado em seis subáreas que apresentam formas de adensamento construtivo e tipologias de cobertura vegetal distintas. Os indicadores encontrados no cenário real (atual) foram: Altiplano 1: IDVAT = 0.06 / IDVDC = 0.4; Altiplano 2: IDVAT = 0.03 / IDVDC = 0.13; Altiplano 3: IDVAT = 0.05 / IDVDC = 0.19; Altiplano 4: IDVAT = 0.13 / IDVDC = 1.59; Altiplano 5: IDVAT = 0.11 / IDVDC = 0.92; Altiplano 6: IDVAT = 0.14 / IDVDC = 0.92. Em seguida, escolheu-se dois cenários reais do bairro para análise dos cenários tendenciais e construção de possíveis alternativos, de modo a compreender os valores dos indicadores em uma situação de proporção mínima de cobertura vegetal com predominância arbórea de média à grande porte. E, por fim, fezse uma breve correlação dos indicadores encontrados com dados microclimáticos da cidade de João Pessoa (Ribeiro, 2013) que auxiliou a visualizar a relação entre os indicadores com valores mais baixos e as áreas com temperaturas mais elevadas e desprovidos de adensamento vegetado. Por fim, espera-se que a evolução do Indicadores para o Verde Urbano (IVU) possa auxiliar a fornecer dados de fundamental importância para alcançar maiores níveis de amenização do rigor climático por meio da proporção mínima entre os volumes vegetados e edificados alocados no espaço urbano, assim como contribuir com estudos de impacto para evitar conflitos no processo de urbanização e promover a implementação de medidas mais equitativas e ambientalmente qualificadas

    Conforto térmico do transeunte : a porosidade urbana como condicionante da ventilação

    Get PDF
    The changes of urban structures associated with the non-inclusion of climate issues in Zoning Ordinances generate environmental consequences that may contribute to the passerby’s thermal discomfort. For regions of hot and humid weather, as the case of VitAs modificações das estruturas urbanas associadas à falta de inclusão de questões climáticas nos Planos Diretores geram consequências ambientais que podem contribuir para o desconforto térmico do transeunte. Para regiões de clima quente e úmido, como o c

    Comparative study of the thermal performance of buried and half-buried test cells in the city of Curitiba - PR

    No full text
    Aiming at a bioclimatic architecture that uses passive methods to reduce the energy consumption, this research has the purpose aim of verifying the thermal performance of buried and semi-buried test cells when compared to a ground control cell. The method is based on the comparison of the temperature indices measured inside two test cells and a control one, both made in reduced scale, with the same dimensions and material specifications regarding the external and soil temperature measured in Curitiba, PR, during the autumn, winter and summer. For the performance evaluation, the thermal amplitude, the thermal delay, the differences in temperature and amplitudes of surface sensors and the comfort indexes of each test cell were analyzed. After the measurements of autumn, winter and summer, treatment and data analysis, it was verified that the buried test cell presented lower thermal amplitude and greater thermal delay. Regarding comfort temperature, the buried test cell obtained the best performance during the fall, winter and summer periods. It was also possible to verify that the larger the area in contact with the soil, the better its thermal and energetic efficiencies.Visando a uma arquitetura bioclimática que utilize métodos passivos para a economia do consumo de energia, esta pesquisa tem o objetivo de verificar o desempenho térmico de células-teste enterradas e semienterradas quando comparadas a uma célula controle térrea. O método é baseado na comparação das variações de temperatura medida no interior de células-teste confeccionadas em escala reduzida, com as mesmas dimensões e especificações de materiais, quanto à temperatura externa e do solo medidos em Curitiba, PR, durante os períodos do outono, inverno e verão. Para a avaliação de desempenho foram analisados a amplitude térmica, o atraso térmico, as diferenças de temperaturas e amplitudes de sensores superficiais e os índices de conforto de cada célula-teste. Após a realização das medições do outono, inverno e verão, o tratamento e a análise de dados, constatou-se que a célulateste enterrada apresentou menor amplitude térmica e maior atraso térmico. No que tange à faixa de conforto, a célula-teste enterrada obteve o melhor desempenho durante os períodos do outono, inverno e verão. Foi possível verificar também que quanto maior a área em contato com o solo, melhores são suas eficiências térmica e energética

    Springtime monitoring of passive cool roofs in subtropical climate

    Get PDF
    Passive strategies for acclimatization of buildings have been studied by several authors in many countries, especially the evaporative and radiant cooling techniques. Fiber cement tiles are very common in popular constructions due to their low cost. However, they have over twice of the value thermal transmittance indicated to this bioclimatic zone according to Brazilian guidelines. The objective is to present an alternative to reduce high temperatures on fiber cement tiles. In this paper, the monitoring of passive cooling of roofing during the spring season in a city with subtropical climate is described. Single and combined reflective and evaporative cooling systems were studied in different environmental conditions. Internal surface temperatures of tiles were monitored together with weather variables. Results show a decrease of about 6 ºC, 9 ºC, 10 ºC and 11 ºC as compared to the original tiles according to environment conditions and the combined passive cooling techniques. These results allow for the conclusion that the use of passive cooling techniques opens up new possibilities to attenuate the internal surface temperatures of tiles and to consequently decrease the roofing solar heat gain into buildings, thus, providing less air cooling energy consumption

    Paredes orientadas a leste e a oeste: uma abordagem crítica em relação ao conforto e à eficiência energética

    Get PDF
    The primary aim of this paper is to compare the thermal and energetic response under periodic conditions of two west-oriented wall systems, which have the same performance when analyzed under steady-state environments. Thermal inertia has been addressed using periodic solutions of the heat conduction equation proposed by Fourier, by means of harmonic analysis, for a period of twenty-four hours, in the region of Campinas - SP. In Brazil, walls and roof systems have traditionally been designed using the steady-state overall heat transfer coefficient (U-value). Uvalues only allow preliminary design decisions for some wall and roof systems, as they do not encompass the dynamic performance of the thermal wave. The results show that two identical walls under steady-state conditions may have very distinct thermal and energetic performances, when analyzed under dynamic environments. The suggested inferences are that the selection of local walls and roof systems should be based on their ability for peak load leveling and on the consequences for cooling energy demand, and that the use pattern of the building has also to be considered.O objetivo principal deste artigo é a comparação térmica e energética em regime periódico de duas paredes com orientação leste e oeste com desempenhos idênticos em regime permanente. O fenômeno da inércia térmica foi analisado empregando-se soluções periódicas para a equação de condução de calor proposta por Fourier. Utilizou-se o método da análise harmônica para cálculo dos coeficientes, através de um período de 24 h, para a região de Campinas, SP. Tradicionalmente no Brasil, sistemas de coberturas e paredes têm sido concebidos com base no coeficiente global de transmitância térmica (U). Os valores de U possibilitam apenas a tomada de decisões preliminares sobre a adoção de determinados sistemas de coberturas e paredes, uma vez que eles não retratam o comportamento dinâmico da onda térmica. Os resultados mostram que duas paredes idênticas em regime permanente podem apresentar comportamentos térmico e energético bastante distintos, quando analisadas em condições dinâmicas. Infere-se, portanto, que a seleção de sistemas de paredes, e também de coberturas, deve se basear nos efeitos sobre a capacidade de nivelamento dos picos de carga térmica e sobre a demanda por energia gerada artificialmente para o conforto, guardando relação também com o regime de utilização da edificação em questão

    Desempenho térmico de fachadas ventiladas opacas: uma revisão sistemática

    Get PDF
    Ventilated facades have been identified as a viable solution to improve the thermal performance of buildings, thereby upgrading their energy efficiency. The literature points out a lack of studies on opaque ventilated facades among the different types of these facades. Thus, this study aims to present research on the thermal performance of opaque ventilated facades using a Systematic Literature Review (SLR), considering where the research was carried out, the method used and the main parameters that influence the thermal performance of these facades. The SLR proved efficient in outlining the desired panorama, indicating that this facade model consists of a technology only recently explored in academia with research concentrated in Europe, mainly in Spain, Italy and Portugal, highlighting the Mediterranean climate as the focus of the research. Most of the studies were conducted using computer simulations, followed by experimental methods that validated the mathematical models of the simulation programs. The SLR identified the outdoor conditions and aspects of the facade geometry that have a higher influence on the thermal performance of these facades. Considering the outdoor environment conditions, solar radiation and the year's seasons were the most discussed parameters in the literature. Considering the facade geometry, the ventilated facade openings (presence or absence of joints and grilles), the cavity height, and the outer skin material were the most studied variables.As fachadas ventiladas têm sido apontadas como uma solução viável para melhoria do desempenho térmico de edifícios, beneficiando, assim, sua eficiência energética. Dentre os diversos tipos desse sistema, a literatura aponta uma escassez de estudos acerca das fachadas ventiladas opacas. Assim, este trabalho tem como objetivo reunir pesquisas sobre o desempenho térmico de fachadas ventiladas opacas por meio da Revisão Sistemática da Literatura (RSL), considerando o local onde as pesquisas foram feitas, o método utilizado e os principais parâmetros que influenciam no desempenho térmico dessas fachadas. A RSL se mostrou eficiente em traçar o panorama desejado, indicando que este modelo de fachada consiste em uma tecnologia explorada apenas recentemente no meio acadêmico, com pesquisas concentradas no continente europeu, principalmente na Espanha, Itália e Portugal, evidenciando o clima mediterrâneo como foco das pesquisas. A maior parte das pesquisas foi realizada com simulações computacionais, seguidos pelos métodos experimentais, que validaram os modelos matemáticos dos programas de simulação. Com a RSL, identificaram-se as condições externas e os aspectos da geometria que mais influenciam no desempenho térmico dessas fachadas. Dentre as condições do meio externo, a radiação solar e as estações do ano foram os parâmetros mais abordados nas pesquisas. Em relação à geometria da fachada, as aberturas na fachada ventilada (presença ou ausência de juntas e grelhas), a altura da cavidade e o material que compõe a camada externa foram as variáveis mais estudadas

    Editorial

    No full text

    Validation of the climatic zoning defined by ASHRAE standard 169-2013

    No full text
    Climatic zoning has a direct impact on building energy efficiency policies. Currently, most countries adopt simplified weather parameters to define their climatic zoning, with the degree-day method being the most widely used. This widespread use of degree-days has been substantially influenced by the adoption of this indicator by ASHRAE on its climatic zoning, which is a core element for the prescription of requirements for buildings based on their location. However, there is no scientific evidence regarding the agreement between building energy performance and the ASHRAE climatic zones. The objective here was to quantify the mismatch between buildings' energy performance in each given location and the expected energy performance in the climatic zone they are placed. The study uses a performance-based assessment method relying on building energy simulation and GIS. Climatic zoning performance indicators were calculated based on the energy demand of 52 archetype buildings of the U.S. building stock complying with the ASHRAE Standard 90.1-2013. Results suggest that the stipulated climatic zone misclassifies 10% of the area evaluated, potentially misclassifying highly populated urban areas. These misclassifications have direct impact on the building energy efficiency policies of a given location, which may not be the most adequate for its climate135CONSELHO NACIONAL DE DESENVOLVIMENTO CIENTÍFICO E TECNOLÓGICO - CNPQFUNDAÇÃO DE AMPARO À PESQUISA DO ESTADO DE SÃO PAULO - FAPESP303377/2017-82018/00976-1; 2017/14617-