181,137 research outputs found

    Data and code for TFlux measurement associated with the publication: PCP-dependent polarized mechanics in the cortex of individual cells during convergent extension

    No full text
    This dataset contains MATLAB scripts and example demonstration files for the TFlux measurement in the publication: Weng, S., Devitt, C. C., Nyaoga, B. M., Alvarado, J. & Wallingford, J. B. PCP-dependent polarized mechanics in the cortex of individual cells during convergent extension. Dev. Biol. 523, 59–67 (2025). https://doi.org/10.1016/j.ydbio.2025.04.007 </a

    Molecular structure of highly excited resonant states in Mg-24 and the corresponding Be-8+O-16 and C-12+C-12 decays

    No full text
    Exotic Be-8 and C-12 decays from high-lying resonances in Mg-24 are analyzed in terms of a cluster model. The calculated quantities agree well with the corresponding experimental data. It is found that the calculated decay widths are very sensitive to the angular momentum carried by the outgoing cluster. It is shown that this property makes cluster decay a powerful tool to determine the spin as well as the molecular structures of the resonances.Physics, NuclearSCI(E)7ARTICLE5null8

    Mitomycin C in highly myopic eyes - Author reply

    No full text
    Ophthalmology. 2005 Feb;112(2):208-18; discussion 219. Mitomycin C modulation of corneal wound healing after photorefractive keratectomy in highly myopic eyes. Gambato C, Ghirlando A, Moretto E, Busato F, Midena E. SourceRefractive Surgery Service and Antimetabolite Therapy Research Unit, Department of Ophthalmology, University of Padova, Padova, Italy. Abstract PURPOSE: To evaluate the role of topical mitomycin C in corneal wound healing (CWH) after photorefractive keratectomy (PRK) in highly myopic eyes. DESIGN: Prospective, double-masked, randomized clinical trial. PARTICIPANTS: Seventy-two eyes of 36 patients affected by high (>7 diopters) myopia. METHODS: In each patient, one eye was randomly assigned to PRK with intraoperative topical 0.02% mitomycin C application, and the fellow eye was treated with a placebo. Postoperatively, mitomycin C-treated eyes received artificial tears (3 times daily, tapered in 3 months), whereas the fellow eye was treated with fluorometholone sodium 2% and artificial tears (3 times daily, tapered in 3 months). MAIN OUTCOME MEASURES: Uncorrected visual acuity (UCVA) and best-corrected visual acuity (BCVA), contrast sensitivity, manifest refraction, and biomicroscopy. Contrast sensitivity was determined using the Pelli-Robson chart. Corneal confocal microscopy documented CWH. RESULTS: Mean follow-up was 18 months (range, 12-36). No side effects or toxic effects were documented. At 12-month follow-up examination, UCVAs (logarithm of the minimum angle of resolution) were 0.4+/-0.48 and 0.5+/-0.53 (P = .03) in mitomycin C-treated eyes and corticosteroid-treated eyes, respectively. At 1 year, corneal haze developed in 20% of corticosteroid-treated eyes, versus 0% of mitomycin C-treated eyes. At 12, 24, and 36 months, corneal confocal microscopy showed activated keratocytes and extracellular matrix significantly more evident in untreated eyes (Ps = 0.004, 0.024, and 0.046, respectively). CONCLUSION: Topical intraoperative application of 0.02% mitomycin C can reduce haze formation in highly myopic eyes undergoing PRK. Comment in Ophthalmology. 2006 Feb;113(2):357; author reply 357-8

    B -&gt; eta K-c(eta &apos; K-c) decays in QCD factorization

    No full text
    We study the exclusive decays of the B meson into pseudoscalar charmonium states eta(c) and eta(c)&apos; within the QCD factorization approach and find that the non-factorizable corrections to naive factorization are infrared safe at leading-twist order. The spectator interactions arising from the kaon twist-3 effects are formally power suppressed but chirally and logarithmically enhanced. An important improvement by including the O(alpha(s)) corrections is the cancellation of the renormalization scale mu dependence of the decay amplitude. However, the calculated decay rates are too small to accommodate the experimental data. On the other hand, we compare the theoretical calculations for B meson decays to J/psi, psi&apos;, eta(c) and eta&apos;(c), and find that the predicted relative decay rates of these four states are approximately compatible with the experimental data.http://gateway.webofknowledge.com/gateway/Gateway.cgi?GWVersion=2&SrcApp=PARTNER_APP&SrcAuth=LinksAMR&KeyUT=WOS:000223097800007&DestLinkType=FullRecord&DestApp=ALL_WOS&UsrCustomerID=8e1609b174ce4e31116a60747a720701Physics, Particles &amp; FieldsSCI(E)17ARTICLE3365-3703

    History sketch 157th Engineer (C) Bn.

    No full text
    This is a historical description of the 157th Engineer (C) Battalion written from memory by author. Notes are not attached as described on last page of document

    Measurement of the ratio of prompt χ c to J / ψ production in pp collisions at √s = 7 TeV

    Full text link
    The prompt production of charmonium χ c and J / ψ states is studied in proton-proton collisions at a centre-of-mass energy of √s = 7 TeV at the Large Hadron Collider. The χ c and J / ψ mesons are identified through their decays χ c → J / ψ γ and J / ψ → μ + μ - using 36 pb - 1 of data collected by the LHCb detector in 2010. The ratio of the prompt production cross-sections for χ c and J / ψ, σ (χ c → J / ψ γ) / σ (J / ψ), is determined as a function of the J / ψ transverse momentum in the range 2 < p T J / ψ < 15 GeV / c. The results are in excellent agreement with next-to-leading order non-relativistic expectations and show a significant discrepancy compared with the colour singlet model prediction at leading order, especially in the low p T J / ψ region

    Microscopic mechanism of charged-particle radioactivity and generalization of the Geiger-Nuttall law

    No full text
    A linear relation for charged-particle emissions is presented starting from the microscopic mechanism of the radioactive decay. It relates the logarithms of the decay half-lives with two variables, called. chi&apos; and. rho&apos;, which depend upon the Q values of the outgoing clusters as well as the masses and charges of the nuclei involved in the decay. This relation explains well all known cluster decays. It is found to be a generalization of the Geiger-Nuttall law in a radioactivity, and therefore we call it the universal decay law. Predictions of the most likely emissions of various clusters are presented by applying the law over the whole nuclear chart. It is seen that the decays of heavier clusters with nonequal proton and neutron numbers are mostly located in the trans-lead region. The emissions of clusters with equal protons and neutrons, like (12)C and (16)O, are possible in some neutron-deficient nuclei with Z &gt;= 54.http://gateway.webofknowledge.com/gateway/Gateway.cgi?GWVersion=2&SrcApp=PARTNER_APP&SrcAuth=LinksAMR&KeyUT=WOS:000271352900039&DestLinkType=FullRecord&DestApp=ALL_WOS&UsrCustomerID=8e1609b174ce4e31116a60747a720701Physics, NuclearSCI(E)51ARTICLE4null8

    O. A. C. Review Volume XLVI Issue 5, February 1934

    No full text
    The focus of this issue is the preparation for College Royal and recognizing its tenth anniversary. This month's agricultural article is a report from the Dominion Parasite Laboratory on the biological control of pests. Other articles provide an account of the activities of a stage manager and the development of the field of home economics at Macdonald College in Quebec. Campus news addresses the success of the 1934 Conversazione, the commemorating of the sixtieth anniversary of the founding of O. A. C., the attendance at the Canadian Author Lecture, and the successful productions of "The Apple Cart" and "Iolanthe". The Macdonald Institute column comments on the Conversat and women's athletics activities in basketball and the rifle club. The Alumni Record supplies alumni updates.EditorialTen Years of the RoyalRamblings on the RoyalBlame it on the stage managerBiological control of insect pests in CanadaNot for girls onlyCollege lifeLiterary sectionO. A. C. sportsfolioAlumni recordMacdonald newsLetters to the editoradvertisin

    A 0.12mm<sup>2</sup> Wien-Bridge Temperature Sensor with 0.1°C (3σ) Inaccuracy from -40°C to 180°C

    No full text
    Resistor-based temperature sensors can achieve much higher resolution and energy efficiency than conventional BJT-based sensors [1], but they typically occupy more area (&gt; 0.25 mm 2 ) and have lower operating temperatures (le 125 {circ} {C}) [2]-[4]. This work describes a 0.12mm 2 resistor-based sensor that uses a Wien-bridge (WB) filter to achieve 0.1 {circ} {C} (3 sigma) inaccuracy from - 40 {circ} {C} to 180 {circ} {C}. Compared to a state-of-the-art WB sensor [4], it occupies 6 × less area and achieves comparable relative accuracy over a 76% wider operating range. Session 10.3 Green Open Access added to TU Delft Institutional Repository ‘You share, we take care!’ – Taverne project https://www.openaccess.nl/en/you-share-we-take-care Otherwise as indicated in the copyright section: the publisher is the copyright holder of this work and the author uses the Dutch legislation to make this work public.Electronic InstrumentationMicroelectronic
    corecore