164,937 research outputs found

    Short communication: Comparative estimation of colostrum quality by Brix refractometry in bovine, caprine, and ovine colostrum.

    No full text
    Newborn ungulates depend on the timely supply of colostrum containing sufficient immunoglobulins to obtain passive immunity against disease. Brix refractometry enables a rapid on-farm estimation of colostrum quality and has been intensively studied in bovines. However, the suitability of Brix refractometers for assessing colostrum quality in goats and ewes has been scarcely evaluated. The present study compared bovine, caprine, and ovine colostrum quality estimation using an optical Brix refractometer. In addition, between-species variations in the relationships between Brix values and colostrum constituents (IgG, fat, protein, and lactose) and the accuracy of Brix refractometry at different cutoff values were evaluated by a receiver operating characteristic curve analysis. We measured the Brix value and contents of IgG, fat, protein, and lactose in 324 colostrum samples (108 cows, 116 does, and 100 ewes). Thresholds for classification of good colostrum quality (as determined by ELISA) were set at 50 mg IgG/mL in cows and 20 mg/mL in does and ewes. Bovine colostrum showed the greatest IgG concentrations compared with caprine and ovine colostrum. Fat and protein content was higher in sheep colostrum compared with the other species, whereas the highest lactose concentrations were detected in goat colostrum. Brix values ranged from 11.4 to 34.6% (22.1 ± 4.2%; mean ± standard deviation), 15.4 to 40.0% (28.5 ± 6.8%), and 8.8 to 39.8% (21.6 ± 5.3%) in bovine, ovine, and caprine colostrum, respectively. In all 3 species, Brix was highly correlated with IgG and protein concentrations (cows, r = 0.83 and 0.98; goats, r = 0.83 and 0.89; sheep, r = 0.75 and 0.87). Optimal cutoff points for greatest accuracy of Brix measurements were 19.3% Brix in cows [with 87.1% sensitivity (Se) and 100% specificity (Sp)], 20.7% Brix in does (with 53.5% Se and 100% Sp), and 26.5% Brix in ewes (with 75% Se and 91.3% Sp). In conclusion, Brix refractometry is an acceptable tool for on-farm estimations of colostrum quality in does and ewes despite distinct between-species variations in colostrum composition

    [Report to Chief J. E. Curry, by an unknown author #1]

    No full text
    Report to Chief J. E. Curry, by an unknown author. The report contains a list of officers who gave depositions to the United States Attorney

    [Report to Chief J. E. Curry, by an unknown author #2]

    No full text
    Report to Chief J. E. Curry, by an unknown author. The report contains a list of officers who gave depositions to the United States Attorney

    #x00B0;Brix sensor based on Lossy Mode Resonances (LMRs)

    No full text
    Publisher Copyright: © 2014 IEEE.The fabrication and characterization of an optical fiber °Brix sensor based on Lossy Mode Resonances (LMRs) is presented. ITO coatings deposited on side-polished D-shaped optical fibers are used as LMR supporting coatings. LMRs are highly sensitive to external medium refractive index variations and enable an accurate determination of sugar concentration in the surroundings of the device by means of a LMR wavelength shift when the device is immersed in sugar based solution. The fabricated sensors have been used to measure sugar concentrations from 5% to 50%, which is within the requirements of most common applications. The response of the devices is linear with a linearity factor R2 0.9961 and a sensitivity of 11.8 nm/°Brix, which means a resolution of ∼0.005 °Brix by using a conventional communications Optical Spectrum Analyzer (OSA). Presented device shows a twenty-fold improvement in sensitivity compared with comercial Brix refractometers.Peer reviewe

    Evaluation of transmission infrared spectroscopy and digital and optical refractometers to identify low immunoglobulin G concentrations in alpaca serum.

    No full text
    This study aimed to evaluate the digital Brix and optical serum total protein (STP) refractometers for measuring concentrations of serum immunoglobulin G (IgG) in alpacas and compare them to IgG concentrations measured by the reference method of radial immunodiffusion (RID) assay. The appropriate cutoff point for Brix and STP refractometers and the transmission infrared (TIR) spectroscopy method was determined for low IgG concentrations (< 10 g/L). Serum samples were collected from alpacas (N = 169) and tested by both refractometers. The correlation between Brix % and STP was high [correlation coefficient (r) = 0.99]. However, the correlation coefficients between Brix % and STP with serum RID-IgG concentrations were only 0.56 and 0.55, respectively. Twenty-one (12.4%) of 169 alpaca serum samples had IgG concentrations of < 10 g/L. Using receiver operator characteristic curve (ROC) analysis, the optimal cutoff points for the TIR assay, digital Brix, and optical STP refractometers for assessing low IgG (RID < 10 g/L) were 13 g/L, 8.8%, and 50 g/L, respectively. The TIR assay showed higher sensitivity (Se = 95.2%) and specificity (Sp = 96.8%) than either the digital Brix (Se = 90.5% and Sp = 65.5%) or optical STP (Se = 81% and Sp = 73.7%) refractometers for assessing alpacas with low IgG. In conclusion, the Brix and STP refractometers lack accuracy in measuring alpaca IgG concentrations, but may be useful for screening animals for low serum IgG. However, the TIR assay with a cutoff point of 13 g/L was more appropriate for identifying low IgG than either refractometer. Another study that focuses on neonatal crias is recommended in order to evaluate the usefulness of these assays for field diagnosing of failure of transfer of passive immunity (FTPI).journal article2017 Julimporte

    Mandarin Market Segments Based on Consumer Sensory Evaluations

    No full text
    Ninety-five consumers in seven grocery stores tasted unidentified peeled sections of three mandarins (a tangerine, a satsuma, and a clementine), and provided demographic and purchase information. Forty-four percent of the respondents preferred tangerines, 34 percent satsumas, and 22 percent clementines. The probability of preferring each of type of mandarin was estimated from internal quality analysis of paired samples, as well as from demographic and purchase responses. Model simulations were used to recommend harvest standards for satsumas based on Brix-to-acid ratios.Demand and Price Analysis, Food Consumption/Nutrition/Food Safety,

    Murder on the mountain: author talk with Peter J. Wosh

    No full text
    Author talk by Peter J. Wosh on May 5th, 2022, on his book, "Murder on the Mountain: crime, passion, and punishment in gilded age New Jersey.

    Mr. Melvin J. Collier, RWWL AUC, June 2011

    No full text
    This video is a conversation with Mr. Melvin J. Collier. Mr. Collier talks about his book, "From Mississippi to Africa: A Journey of Discovery". Daniel Le, AUC Woodruff Library, is the interviewer

    A Tripartite Post-Recession Rebalancing

    No full text
    In this latest Advance & Rutgers Report, entitled “A Tripartite Post-Recession Rebalancing,” Dean James W. Hughes and Professor Joseph J. Seneca deliver an incisive assessment of the current market conditions and obstacles in the path of our economic recovery. They offer a statistical cautionary tale that the private and public sector need to hear and acknowledge in order for the economy to make continued progress.This report was published as Issue Paper Number 7, November 2011, in Advance & Rutgers Report

    Evidence for the decay B0→J/ψω and measurement of the relative branching fractions of meson decays to J/ψη and J/ψη′

    No full text
    First evidence of the B 0 → J / ψ ω decay is found and the B s 0 → J / ψ η and B s 0 → J / ψ η ′ decays are studied using a dataset corresponding to an integrated luminosity of 1.0 fb -1 collected by the LHCb experiment in proton-proton collisions at a centre-of-mass energy of sqrt(s) = 7 TeV. The branching fractions of these decays are measured relative to that of the B 0 → J / ψ ρ 0 decay:frac(B (B 0 → J / ψ ω), B (B 0 → J / ψ ρ 0)) = 0.89 ± 0.19 (stat) - 0.13 + 0.07 (syst),frac(B (B s 0 → J / ψ η), B (B 0 → J / ψ ρ 0)) = 14.0 ± 1.2 (stat) - 1.5 + 1.1 (syst) - 1.0 + 1.1 (frac(f d, f s)),frac(B (B s 0 → J / ψ η ′), B (B 0 → J / ψ ρ 0)) = 12.7 ± 1.1 (stat) - 1.3 + 0.5 (syst) - 0.9 + 1.0 (frac(f d, f s)), where the last uncertainty is due to the knowledge of f d / f s, the ratio of b-quark hadronization factors that accounts for the different production rate of B 0 and B s 0 mesons. The ratio of the branching fractions of B s 0 → J / ψ η ′ and B s 0 → J / ψ η decays is measured to befrac(B (B s 0 → J / ψ η ′), B (B s 0 → J / ψ η)) = 0.90 ± 0.09 (stat) - 0.02 + 0.06 (syst)
    corecore