127 research outputs found

    La Poetica della traduzione di Machado de Assis in italiano: o Anjo Rafael

    No full text
    Tese (doutorado) - Universidade Federal de Santa Catarina, Centro de Comunicação e Expressão, Programa de Pós-Graduação em Estudos da Tradução, Florianópolis, 2010This thesis is based on a research project on the translations of Machado de Assis published in Italy. It aims to verify how and in what way the Brazilian author is positioned in Italian literary culture, and based on this it moves on to describe the importance of translational and critical activities in the reception of a writer from a peripheral literary system by another literary system. Peeter Torop#s concept of total translation is the main theoretical reference adopted for the individuation of the translational strategies for Machado de Assis# works in general, based on the stylistic description of his criticism, and of O Anjo Rafael [The Angel Raphael] in particular. This little known short story by Machado de Assis is presented, analysed and translated for the first time into Italian. In conclusion observations and commentaries on the translational process will show the poetics of translation adopted in this particular translation of Machado de Assis short story.Esta tese parte de um trabalho de pesquisa sobre as traduções de Machado de Assis publicadas na Itália para verificar em que medida e com quais características o autor brasileiro esteja inserido na cultura literária italiana, e da qual se parte para delinear a importância das atividades tradutória e crítica na recepção de um escritor pertencente a um sistema literário periférico em outro sistema literário. O conceito de tradução total de Peeter Torop é a principal referência teórica adotada para a individuação das estratégias tradutórias da obra em geral de Machado de Assis, com base na descrição estilística de seus críticos, e de O Anjo Rafael especialmente. Trata-se de um conto pouco conhecido de Machado de Assis que vem aqui apresentado, analisado e traduzido pela primeira vez para o italiano. As observações e os comentários sobre o processo tradutório concluem este trabalho, evidenciando a poética da tradução adotada na tradução específica deste conto de Machado de Assis

    Avaliação funcional e ecocardiográfica por ensaio clínico randomizado dos efeitos agudos de dois modos de ventilação não-invasiva nasal na insuficiência cardíaca aguda

    No full text
    Introdução: O CPAP tem sido retratado como efetivo tratamento para pacientes com insuficiência cardíaca (IC) e distúrbios relatados de sono. Em pacientes com IC pósdescompensação, os efeitos da VNI são conflitantes quanto aos resultados na capacidade funcional e função cardíaca. Objetivo: Avaliar os efeitos da VNI com dois modos ventilatórios em pacientes com IC na avaliação da capacidade funcional através do teste da caminhada dos 6 minutos (TC6m) e parâmetros ecocardiográficos da função cardíaca. Métodos: Ensaio clínico randomizado, 34 pacientes com diagnóstico de IC (critérios de Framinghan) receberam VNI por máscara nasal pelo modo contínuo (n=17) ou duplo nível (n=17). Após 60 minutos de aplicação de VNI, realizou-se Ecocardiografia para avaliação da função cardíaca e TC6m para avaliação da capacidade funcional. Resultados: A média de idade no grupo CPAP foi de 62,6±14,5 anos e duplo-nível de 63,4±11 anos. A pressão utilizada foi de 8cmH2O no modo contínuo e 8 e 4cmH2O no duplo-nível. Pacientes com função sistólica anormal (FEVE<50%) corresponderam a 61,8% da amostra (n=21) e pacientes com FEVE preservada (FEVE>= 50%) corresponderam a 38,2% (n=13). Aumento significativo de 5,2% foi observado na distância percorrida no TC6m pelos pacientes com FEVE<50% após o uso agudo VNI (pré:357,9±85,6 vs pós:376,4±72,9 metros, p=0,006). Foi verificado, além disso, redução significativa no diâmetro da veia cava inferior após uso do CPAP (pré:15,4±7,2 vs pós:12,1±6,4 p=0,046) e diminuição na sensação subjetiva de dispnéia através da escala de BORG. Esta diminuição na sensação de dispnéia foi relatada ao final da caminhada após o uso da VNI (de 4,4 ± 2,8 para 3,7 ± 2,5 n=34, p=,043). Nenhuma correlação foi observada entre a variação na distância percorrida no TC6m e a variação na FEVE pós-VNI (r= 0,088; p=0,619; n=34). Conclusão: O efeito benéfico na distância percorrida no TC6m após a VNI mostrou-se dependente de função contrátil ventricular anormal nos pacientes participantes de nosso estudo. Porém, houve diminuição na percepção subjetiva de dispnéia através da escala de BORG nos pacientes com FEVE anormal e também preservada. Dessa forma, concluímos que a aplicação aguda de VNI produziu alívio da dispnéia, mas somente nos pacientes com FEVE <50%, este achado se traduziu em melhora ao esforço submáximo.Background: CPAP (Continuous positive airway pressure) has shown evidences of being a safe and effective adjunct night treatment for patients with heart failure (HF) and reported sleep disorders. However, regarding post decompensation patients without reported sleep disorders, the results of current studies are conflicting in terms of benefits provided by this technique on the functional capability and cardiac function. Objective: To assess the effects of nasal non-invasive ventilation (NIV) through CPAP ventilation mode comparing the double level in HF patients in the assessment of the functional capability through the 6- minute walk test (6MWT) and in echocardiographic parameters of the cardiac function. Methods, Measurements: Randomized clinical study, 34 patients that presented Framingham criteria for HF were randomized for CPAP ventilation mode (n=17) or Double level mode (n=17). After patients received a 60-minute intervention (NIV), was performed echocardiography again to assess the cardiac function and 6MWT to functional capability assessment. Main Results: The mean age of CPAP group was 62,6 ± 14,5 years and Double level was 63,4 ± 11 years. The airways pressure applied was 8 cmH2O of CPAP, and 8 cmH2O and 4 cmH2O of Double level. Patients with abnormal systolic function (LVEF<50%) corresponded to 61,8% of the sample (n=21) and patients with preserved systolic function (LVEF>=50%) corresponded to 38,2% of the sample. A significant increase of 5,2% was observed in the distance walked by patients with LVEF<50% after NIV (before=357.9 ± 85.6 meters vs. after=376.4 ± 72.9 meters, n=21, p=0.006). In addition, a significant reduction of the Inferior Vena Cava (IVC) diameter was observed in patients that utilized CPAP ventilation mode (before=15.4 ± 7.2 vs. after=12.1 ± 6.4, n=17, p=0.046) and in the subjective sensation of dyspnea through BORG Scale. This reduction in dyspnea sensation was reported at the end of the walk after the utilization of NIV (from 4.4 ± 2.8 to 3.7 ± 2.5, n=34, p=.043), however no difference was determined regarding the groups of ventilation modes compared. No correlation was observed between the variation of walked distance in the 6MWT and the variation of LVEF after NIV (r= 0.088; p=0.619; n=34). Conclusion: The positive effect on walked distance in the 6MWT of NIV showed to be dependent on a ventricular contractile function up to 50% in our patients. However, after the NIV, a reduction was observed in the subjective dyspnea perception reported by means of BORG scale in patients with abnormal and preserved LVEF. However, this improvement was not verified in cardiovascular hemodynamic variables through echocardiography, except for the IVC diameters. This way, additional studies involving larger samples are required to have a better understanding of NIV effects on functional capacity

    Práticas de pré-oxigenação em um serviço de emergência

    No full text
    Resumo não disponíve

    Investigação da hiperinsuflação pulmonar dinâmica durante o exercício e sua relação com a força dos músculos inspiratórios em pacientes com insuficiência cardíaca

    No full text
    INTRODUÇÃO: Estudos prévios demonstram que pacientes com insuficiência cardíaca (IC) podem apresentar redução dinâmica na capacidade inspiratória (CI) durante o exercício associada à redução da capacidade aeróbia. Poucas informações estão disponíveis atualmente sobre se esta redução está relacionada a anormalidades da mecânica ventilatória ou à disfunção muscular inspiratória. OBJETIVOS: Comparar a atividade muscular inspiratória e a intensidade da dispneia durante o exercício em pacientes com IC estável que apresente (Grupo 1) ou não (Grupo 2) redução da CI durante o exercício. MÉTODOS: Foram avaliados 16 pacientes com IC clinicamente estáveis (11 homens, 30 ± 5% de fração de ejeção) e não obesos tratados de acordo com diretrizes baseadas em evidências, sem outras doenças sistêmicas ou evidência espirométrica de obstrução do fluxo aéreo (VEF1/CVF = 83 ± 5%). Os pacientes realizaram teste de exercício cardiopulmonar incremental com medidas seriadas de CI, percepção de dispneia (Borg) e monitoramento contínuo das pressões esofágica (Pes) e gástrica (Pga). A pressão transdiafragmática (Pdi) foi obtida a partir de Pga–Pges. As manobras de Sniff e pressão inspiratória máxima (PImax) foram comparadas em repouso e imediatamente após o exercício. RESULTADOS: Quatro pacientes (25%, Grupo 1) apresentaram redução da CI durante o exercício (-0,18 ± 0,01 vs 0,28 ± 0,05L, p < 0,05). Não houve diferença significativa entre os grupos na função pulmonar e variáveis ecocardiográficas, exceto por uma menor capacidade residual funcional no Grupo 1 (72 ± 9 vs 97 ± 17%; p < 0,05) e menor PImax no Grupo 2 (-101± 25 vs 67 ± 24 cmH2O, p < 0,05). Pes,Sniff (Grupo 1: -77,9 ± 8,7 a -79,6 ± 8,8; Grupo 2: -63,3 ± 4,8 a -66,3 ± 3,8 cmH2O) e Pdi,Sniff (Grupo 1: 116,3 ± 13,9 a 118,3 ± 14,2; Grupo 2: 92,3 ± 5,6 a 98,0 ± 6,0 cmH2O) não diminuíram significativamente com o exercício, assim como Pes,PImax (Grupo 1: -90,5 ± 6,2 a 90,0 ± 9,7; Grupo 2: -64,5 ± 7,3 a 62,3 ± 7,5 cmH2O) e Pdi,PImax (Grupo 1: 140,0 ± 14,0 a 129,3 ± 15,1; Grupo 2: 102,1 ± 15,4 a 90,4 ± 11,4 cmH2O). Apesar de Pga e Pdi terem reduzido ao longo das manobras seriadas de CI durante o exercício no Grupo 1, a Pes não diferiu entre os grupos. A dispneia também foi semelhante entre os grupos. Por fim, o Grupo 1 apresentou volume de reserva inspiratório menor que o Grupo 2 somente no pico do exercício (0,90 ± 0,08 vs 1,47 ± 0,21L; p <0,05). CONCLUSÃO: A redução da CI durante o exercício em alguns pacientes com IC parece ser acompanhada por queda da força diafragmática que é totalmente compensada pelos músculos inspiratórios acessórios. O Grupo 1 apresentou dispneia similar em relação ao grupo 2, provavelmente, pelo fato de o exercício ter sido interrompido antes de os pacientes atingirem limiares ventilatórios críticos para expansão do volume corrente.BACKGROUNG: It has been described that patients with chronic heart failure (CHF) may present with dynamic reduction in inspiratory capacity (IC), which was associated with low peak aerobic capacity. Little information is currently available about whether this reduction is related to respiratory mechanics abnormalities or to impaired inspiratory muscle function. OBJECTIVE: To compare inspiratory muscle activity and intensity of dyspnea during exercise in stable patients with CHF presenting (Group 1) or not (Group 2) with dynamic reduction in IC. METHODS: We studied 16 clinically stable, non obese patients with CHF (11 males, 30 ± 5% ejection fraction) treated according to current evidence-based guidelines with no other systemic diseases or spirometric evidence of airflow obstruction (FEV1/FVC = 83 ± 5%). They performed incremental cardiopulmonary cycle exercise test with serial measurements of IC, dyspnea rating (Borg), and continuous monitoring of esophageal (Pes) and gastric (Pga) pressures. Transdiaphragmatic pressure (Pdi) was obtained from Pga–Pes. Sniff and maximal inspiratory pressure (MIP) maneuvers were compared at rest and immediately post exercise. RESULTS: Four patients (25%, Group 1) showed IC reduction during exercise (-0.18 ± 0.02 vs 0.28 ± 0.19L; p<0.05). There were no significant between-groups differences in lung function and echocardiographic variables, except for a lower functional residual capacity (72 ± 9 vs 97 ± 17%; p < 0.05) in Group 1 and a lower MIP (-101 ± 25 vs 67 ± 24 cm H2O; p < 0.05) in Group 2. Pes,Sniff (Group 1: -77.9 ± 8.7 to -79.6 ± 8.8; Group 2: -63.3 ± 4.8 to -66.3 ± 3.8 cmH2O) and Pdi,Sniff (Group 1: 116.3 ± 13.9 to 118.3 ± 14.2; Group 2: 92.3 ± 5.6 to 98.0 ± 6.0 cmH2O) did not significantly decrease with exercise. Despite Pga and Pdi felt along successive IC maneuvers in Group 1, Pes did not differ between groups. Dyspnea was also similar between groups. Finally, inspiratory reserve volume was lower in Group 1 only at peak exercise (0.90 ± 0.08 vs 1.47 ± 0.21L; p <0.05). CONCLUSIONS: Decrements in exercise IC in some patients with CHF seems accompanied by a dynamic impairment in diaphragm strength that is fully compensated by other inspiratory rib cage muscles. Group 1 presented similar dyspnea compared to Group 2 probably because they stopped exercise before reaching critical ventilatory constraints to tidal volume expansion

    Impacto da limitação ao fluxo expiratório durante volume corrente em repouso sobre a mecânica respiratória, dispneia e função cardiovascular durante o exercício em indivíduos com doença pulmonar obstrutiva crônica

    No full text
    Introdução: Embora não seja um conceito novo, a presença de limitação do fluxo expiratório (LFE) pelo alinhamento da alça de fluxo-volume corrente (FVc) dentro da máxima alça fluxo-volume derivada de uma manobra de capacidade vital forçada precisa ser melhor avaliada para uma melhor utilidade clínica. Nesse sentido, o presente estudo investigou o impacto da LFE detectada em repouso por essa técnica na mecânica respiratória e na percepção da dispneia durante o exercício em pacientes com DPOC moderada a muito grave. Além disso, nosso objetivo foi investigar se o recrutamento excessivo de músculos expiratórios durante o exercício, na presença de LFE em repouso, afetaria a hiperinsuflação dinâmica e as respostas cardiocirculatórias ao exercício. Métodos: Pacientes com DPOC e controles pareados realizaram o teste de exercício cardiopulmonar incremental até a exaustão. As manobras da capacidade inspiratória (CI) foram medidas em repouso, a cada minuto durante o exercício e no pico do exercício. Pressão esofágica (Pes) e gástrica (Pga) foram continuamente monitoradas. Considerou-se LFE significativo quando > 50% da média das alças de FVc expiradas em repouso atingiram ou excedederam o limite expiratório da alça máxima obtida anteriormente da espirometria. A Pga expiratória (Pga, exp) foi a mais positiva durante a expiração do volume corrente e foi expressa em relação à Pga máxima obtida nas manobras de capacidade vital forçada pré-exercício (Pga, FVC). Um aumento na Pga,exp/Pga,CVF ≥ 15% do repouso ao pico do exercício foi considerado indicativo de recrutamento muscular expiratório “excessivo”. Resultados: Trinta e sete pacientes com DPOC (21 homens, 63,1±9,2 anos, VEF1 = 37±12% do previsto) e 9 indivíduos controles pareados foram incluídos. Apenas seis pacientes com DPOC não apresentaram LFE em repouso. O grupo com LFE mostrou um decréscimo mais pronunciado na CI, atingindo volumes pulmonares críticos mais cedo, onde houve um platô na expansão do volume corrente e um aumento súbito na frequência respiratória e percepção dispneia. Entre os pacientes com DPOC com limitação do fluxo expiratório, metade [16/31 (52%)] apresentou recrutamento excessivo de músculos abdominais sem apresentar diferenças significativas nas respostas metabólicas, circulatórias, ventilatórias e sensoriais durante o exercício. Conclusões: Pacientes com LFE desde o repouso apresentaram pior mecânica respiratória levando a maior percepção da dispneia do que o grupo sem xi LFE e os indivíduos controles. O recrutamento excessivo de músculos expiratórios durante o exercício foi observado exclusivamente em pacientes com LFE e não evitou ou adiou a hiperinsuflação dinâmica nem prejudicou as respostas cardiocirculatórias.Background: Although not a new concept, the presence of expiratory flow limitation (EFL) by aligning the tidal flow-volume (FV) loop within the maximal envelope derived from a forced vital capacity maneuver need to be further assessed for utility in the clinical setting. Accordingly, the present study has investigated the impact of EFL detected at rest by this technique on respiratory mechanics and dyspnea perception during exercise in patients with moderate to very-severe COPD. Additionally, we aimed to investigate if excessive expiratory muscle recruitment during exercise in the presence of resting EFL would affect dynamic hyperinflation and cardiocirculatory responses to exercise. Methods: Patients with COPD and paired controls performed incremental cycling cardiopulmonary exercise testing system until exhaustion. Inspiratory capacity (IC) maneuvers after 3-4 sequential tidal FV loops were measured at rest, every second minute during exercise, and at peak exercise. Esophageal (Pes) and gastric pressure (Pga) were continuously monitored. Significant EFL was considered if >50% of the average resting tidal FV loops meet or exceed the expiratory boundary of the maximal loop previously obtained from spirometry. Expiratory Pga (Pga,exp) was the most positive values during tidal volume expiration and was expressed relative to maximum Pga obtained on pre-exercise forced vital capacity maneuvers (Pga, FVC). An increase in Pga,exp/Pga,FVC ≥15% from rest to peak exercise was considered indicative of “excessive” abdominal muscle recruitment. Results: Thirty seven COPD patients (21 male, 63.1±9.2yr, FEV1=37±12% pred) and 9 matched controls were included. Only six COPD patients did not present EFL at rest. The EFL+ group showed a more pronounced decrement in IC, reaching earlier critical operating lung volumes, where there were a plateau in VT expansion and a sudden raise in Fb and dyspnea perception. Among COPD flow limited participants, half [16/31(52%)] showed excessive abdominal muscle recruitment without presenting significant differences in metabolic, circulatory, ventilatory and sensorial responses during exercise. Conclusions: Patients with EFL since rest showed worse exertional respiratory mechanics leading to higher dyspnea perception than their counterparts and matched controls. Excessive expiratory muscle recruitment during exercise was observed exclusively in flow limited patients and has not avoided or postponed exertional hyperinflation neither impaired cardiocirculatory responses

    Female portraits in Fernanda Botelho’s fictional cycle: narratives voices and melancholy atmosphere

    No full text
    Fernanda Botelho (1926–2007) é autora de uma obra ficcional marcada pela originalidade em vários aspectos, que se estende por cerca de meio século, embora se conta entre as escritores contemporâneas injustamente esquecidas. No ciclo ficcional de Fernanda Botelho da década de 1990, dotado de afinidades diversas – Festa em Casa de Flores (1990), Dramaticamente vestida de negro (1994) e As Contadoras de histórias (1998) –, a escritora detém-se na análise de significativa galeria de figuras femininas e em algumas das questões envolventes, num quotidiano dominado por uma banalidade inquietante: ponto de vista e consciência crítica; psicologia e identidade; relações interpessoais e condição social; sentimentos de angústia e papel da memória; ambiguidade e inconformismo ético-social; manifestações de humor e de ironia.Fernanda Botelho (1926–2007) is the author of a fictional work marked by originality in many respects, which spans about half a century, although it is among the unjustly forgotten contemporary writers. In Fernanda Botelho’s fictional cycle of the 1990s, endowed with different affinities – Festa em Casa de Flores (1990), Dramaticamente vestida de negro (1994) and As Contadoras de histórias (1998) –, the writer focuses on the analysis of significant gallery of female figures and some of the surrounding issues, in a daily life dominated by a disturbing banality: point of view and critical awareness; psychology and identity; interpersonal relationships and social condition; feelings of anguish and role of memory; ambiguity and ethical-social non-conformism; manifestations of humor and irony.info:eu-repo/semantics/publishedVersio
    corecore