1,720,959 research outputs found

    Diagnostic accuracy of ultrasound in detecting the depth of invasion in women at risk of abnormally invasive placenta: A prospective longitudinal study

    No full text
    IntroductionThe aim of this study was to assess the diagnostic accuracy of ultrasound in detecting the depth of abnormally invasive placenta in women at risk.Material and methodsProspective longitudinal study including women with placenta previa and at least one prior cesarean delivery or uterine surgery. Depth of abnormally invasive placenta was defined as the degree of trophoblastic invasion through the myometrium and was assessed with histopathological analysis. The ultrasound signs explored were: loss of clear zone, placental lacunae, bladder wall interruption, uterovesical hypervascularity, and increased vascularity in the parametrial region.ResultsIn all, 210 women were included in the analysis. When using at least one sign, ultrasound had an overall sensitivity of 100% (95% CI 96.5-100) and overall specificity of 61.9 (95% CI 51.9-71.2) for all types of abnormally invasive placenta. Using two ultrasound signs increased the diagnostic accuracy in terms of specificity (100%, 95% CI 96.5-100) but did not affect sensitivity. When stratifying the analysis according to the depth of placental invasion, using at least one sign had a sensitivity of 100% (95% CI 93.7-100) and 100% (95% CI 92.6-100) for placenta accreta/increta and percreta, respectively. Using three ultrasound signs improved the detection rate for placenta percreta with a sensitivity of 100% (95% CI 92.6-100) and a specificity of 77.2% (95% CI 69.9-83.4).ConclusionUltrasound has a high diagnostic accuracy in detecting the depth of placental invasion when applied to a population with specific risk factors for anomalies such as placenta previa and prior cesarean delivery or uterine surgery

    First‐trimester detection of abnormally invasive placenta in high‐risk women: systematic review and meta‐analysis

    No full text
    Objectives The primary aim of this systematic review was to ascertain whether ultrasound signs suggestive of abnormally invasive placenta (AIP) are present in the first trimester of pregnancy. Secondary aims were to ascertain the strength of association and the predictive accuracy of such signs in detecting AIP in the first trimester.Methods An electronic search of MEDLINE, EMBASE, CINAHL and Cochrane databases (2000-2016) was performed. Only studies reporting on first-trimester diagnosis of AIP that was subsequently confirmed in the third trimester either during operative delivery or by pathological examination were included. Meta-analysis of proportions, random-effects meta-analysis and hierarchical summary receiver-operating characteristics curve analysis were used to analyze the data.Results Seven studies, involving 551 pregnancies at high risk of AIP, were included. At least one ultrasound sign suggestive of AIP was detected in 91.4% (95% CI, 85.8-95.7%) of cases with confirmed AIP. The most common ultrasound feature in the first trimester of pregnancy was low implantation of the gestational sac close to a previous uterine scar, which was observed in 82.4% (95% CI, 46.6-99.8%) of cases. Anechoic spaces within the placental mass (lacunae) were observed in 46.0% (95% CI, 10.9-83.7%) and a reduced myometrial thickness in 66.8% (95% CI, 45.2-85.2%) of cases affected by AIP. Pregnancies with a low implantation of the gestational sac had a significantly higher risk of AIP (odds ratio, 19.6 (95% CI, 6.7-57.3)), with a sensitivity 93.4% (95% CI, 90.5-95.7%), respectively.Conclusions Ultrasound signs of AIP can be present during the first trimester of pregnancy, even before 11 weeks' gestation. Low anterior implantation of the placenta/gestational sac close to or within the scar was the most commonly seen early ultrasound sign suggestive of AIP, although its individual predictive accuracy was not high

    First trimester detection of abnormally invasive placenta in women at risk: a systematic review and meta-analysis

    No full text
    Objectives The primary aim of this systematic review was to ascertain whether ultrasound signs suggestive of abnormally invasive placenta (AIP) are present in the first trimester of pregnancy. Secondary aims were to ascertain the strength of association and the predictive accuracy of such signs in detecting AIP in the first trimester. Methods An electronic search of MEDLINE, EMBASE, CINAHL and Cochrane databases (2000-2016) was performed. Only studies reporting on first-trimester diagnosis of AIP that was subsequently confirmed in the third trimester either during operative delivery or by pathological examination were included. Meta-analysis of proportions, random-effects meta-analysis and hierarchical summary receiver-operating characteristics curve analysis were used to analyze the data. Results Seven studies, involving 551 pregnancies at high risk of AIP, were included. At least one ultrasound sign suggestive of AIP was detected in 91.4% (95% CI, 85.8-95.7%) of cases with confirmed AIP. The most common ultrasound feature in the first trimester of pregnancy was low implantation of the gestational sac close to a previous uterine scar, which was observed in 82.4% (95% CI, 46.6-99.8%) of cases. Anechoic spaces within the placental mass (lacunae) were observed in 46.0% (95% CI, 10.9-83.7%) and a reduced myometrial thickness in 66.8% (95% CI, 45.2-85.2%) of cases affected by AIP. Pregnancies with a low implantation of the gestational sac had a significantly higher risk of AIP (odds ratio, 19.6 (95% CI, 6.7-57.3)), with a sensitivity 93.4% (95% CI, 90.5-95.7%), respectively. Conclusions Ultrasound signs of AIP can be present during the first trimester of pregnancy, even before 11 weeks' gestation. Low anterior implantation of the placenta/gestational sac close to or within the scar was the most commonly seen early ultrasound sign suggestive of AIP, although its individual predictive accuracy was not high

    Changes in ultrasonography indicators of abnormally invasive placenta during pregnancy

    No full text
    Objective: To ascertain whether the prevalence of ultrasonography signs of abnormally invasive placenta (AIP) changes during pregnancy. Methods: The present retrospective analysis included women with a prenatal diagnosis of AIP that was confirmed at delivery between January 1, 2007, and April 30, 2017, at the Department of Obstetrics and Gynaecology, Arnas Civico Hospital, Palermo, Italy. Ultrasonography signs of AIP were recorded at four different intervals during pregnancy: early first (6â 9 weeks), first (11â 14 weeks), second (15â 24 weeks), and third trimester (25â 36 weeks). Results: There were 105 pregnancies included. Low implantation of the gestational sac was present on all ultrasonography images from the early first trimester compared with on 23 of 83 (27.7%) images from 11â 14 weeks of pregnancy. The identification of loss of the clear space, placental lacunae, bladder wall interruption, and uterovesical hypervascularity all increased (all P<0.001) from the early first trimester onwards; these could all be identified in a majority of patients at 11â 14 weeks of pregnancy. Conclusions: The prevalence of ultrasonography signs suggestive of AIP varied throughout pregnancy. During the early first trimester, indicators of AIP were similar to those of a cesarean scar pregnancy; classical ultrasonography signs of AIP were already present at 11â 14 weeks of pregnancy for most patients

    Going Beyond Counting First Authors in Author Co-citation Analysis

    Get PDF
    The present study examines one of the fundamental aspects of author co-citation analysis (ACA) - the way co-citation counts are defined. Co-citation counting provides the data on which all subsequent statistical analyses and mappings are based, and we compare ACA results based on two different types of co-citation counting - the traditional type that only counts the first one among a cited work's authors on the one hand and a non-traditional type that takes into account the first 5 authors of a cited work on the other hand. Results indicate that the picture produced through this non-traditional author co-citation counting contains more coherent author groups and is therefore considerably clearer. However, this picture represents fewer specialties in the research field being studied than that produced through the traditional first-author co-citation counting when the same number of top-ranked authors is selected and analyzed. Reasons for these effects are discussed

    Diagnostic accuracy of ultrasound in detecting the depth of invasion in women at risk of abnormally invasive placenta: A prospective longitudinal study

    No full text
    Introduction: The aim of this study was to assess the diagnostic accuracy of ultrasound in detecting the depth of abnormally invasive placenta in women at risk. Material and methods: Prospective longitudinal study including women with placenta previa and at least one prior cesarean delivery or uterine surgery. Depth of abnormally invasive placenta was defined as the degree of trophoblastic invasion through the myometrium and was assessed with histopathological analysis. The ultrasound signs explored were: loss of clear zone, placental lacunae, bladder wall interruption, uterovesical hypervascularity, and increased vascularity in the parametrial region. Results: In all, 210 women were included in the analysis. When using at least one sign, ultrasound had an overall sensitivity of 100% (95% CI 96.5-100) and overall specificity of 61.9 (95% CI 51.9-71.2) for all types of abnormally invasive placenta. Using two ultrasound signs increased the diagnostic accuracy in terms of specificity (100%, 95% CI 96.5-100) but did not affect sensitivity. When stratifying the analysis according to the depth of placental invasion, using at least one sign had a sensitivity of 100% (95% CI 93.7-100) and 100% (95% CI 92.6-100) for placenta accreta/increta and percreta, respectively. Using three ultrasound signs improved the detection rate for placenta percreta with a sensitivity of 100% (95% CI 92.6-100) and a specificity of 77.2% (95% CI 69.9-83.4). Conclusion: Ultrasound has a high diagnostic accuracy in detecting the depth of placental invasion when applied to a population with specific risk factors for anomalies such as placenta previa and prior cesarean delivery or uterine surgery

    Variations on the Author

    Get PDF
    “Variations on the Author” discusses two of Eduardo Coutinho’s recent films (Um Dia na Vida, from 2010, and Últimas Conversas, posthumously released in 2015) and their contribution to the general question of documentary authorship. The director’s filmography is characterized by a consistent yet self-effacing form of authorial self-inscription: Coutinho often features as an interviewer that rather than express opinions propels discourses; an interviewer that is good at listening. This mode of self-inscription characterizes him as an author who is not expressive but who is nonetheless markedly present on the screen. In Um Dia na Vida, however, Coutinho is completely absent form the image, while Últimas Conversas, on the contrary, includes a confessional prologue that moves the director from the margins to the center of his films. This article examines the ways in which these works stand out in the filmography of a director who offers new insights into the notion of cinematic authorship

    Appropriate Similarity Measures for Author Cocitation Analysis

    Get PDF
    We provide a number of new insights into the methodological discussion about author cocitation analysis. We first argue that the use of the Pearson correlation for measuring the similarity between authors’ cocitation profiles is not very satisfactory. We then discuss what kind of similarity measures may be used as an alternative to the Pearson correlation. We consider three similarity measures in particular. One is the well-known cosine. The other two similarity measures have not been used before in the bibliometric literature. Finally, we show by means of an example that our findings have a high practical relevance.information science;Pearson correlation;cosine;similarity measure;author cocitation analysis

    Dispelling the Myths Behind First-author Citation Counts

    Get PDF
    We conducted a full-scale evaluative citation analysis study of scholars in the XML research field to explore just how different from each other author rankings resulting from different citation counting methods actually are, and to demonstrate the capability of emerging data and tools on the Web in supporting more realistic citation counting methods. Our results contest some common arguments for the continued use of first-author citation counts in the evaluation of scholars, such as high correlations between author rankings by first-author citation counts and other citation counting methods, and high costs of using more realistic citation counting methods that are not well-supported by the ISI databases. It is argued that increasingly available digital full text research papers make it possible for citation analysis studies to go beyond what the ISI databases have directly supported and to employ more sophisticated methods
    corecore