1,720,964 research outputs found

    Influence of environmental temperature, heat-treatment and design on the cyclic fatigue resistance of three generations of a single-file nickel-titanium rotary instrument

    No full text
    The aim of the present study was to evaluate the effect of environmental temperature, heat-treatment*** and design on the cyclic fatigue resistance of OneShape (OS), OneShape new generation (OSNG) and One Curve (OC) NiTi rotary single-file instruments. Cyclic fatigue testing of NiTi instruments was performed in an artificial canal with a 5-mm radius of curvature and a 60° angle of curvature located 5 mm from the tip of the instrument. During the experiment 3 different temperatures were used in a thermostatic bath with electronic and infrared controls: 0°, 20° and 35 °C. Sixty OneShape, 60 OneShape new generation and 60 One Curve instruments were rotated in the artificial canal until fracture occurred and the number of cycles to fracture (NCF) and the length of the fractured fragment (FL) was recorded. Data were analyzed by one-way ANOVA test at the 5% significance level. Fatigue resistance was significantly higher as the environmental temperature decreased, with differences ranging from 61 to 791%. OC instruments were significantly more resistant to cyclic fatigue than OS and OSNG instruments at all the temperatures tested (P 0.05). Within the limitation of the present study, fatigue resistance of the files was significantly increased when the environmental temperature decreased. OC instruments were significantly more resistant to cyclic fatigue than OS and OSNG instruments at all the temperatures tested

    Efficacy of sonic and ultrasonic irrigation devices in the removal of debris from canal irregularities in artificial root canals

    Full text link
    Abstract Objective To evaluate the efficacy of different sonic and ultrasonic devices in the elimination of debris from canal irregularities in artificial root canals. Materials and Methods A resin model of a transparent radicular canal filled with dentin debris was used. Five groups were tested, namely: Group 1 – ultrasonic insert 15.02; Group 2 – ultrasonic insert 25/25 IRRI K; Group 3 – ultrasonic insert 25/25 IRRI S; Group 4 – sonic insert 20/28 Eddy on a vibrating sonic air-scaler handpiece; Group 5 – 20.02 K-file inserted on a Safety M4 handpiece. Two different irrigants (5% sodium hypochlorite and 17% EDTA) and 3 different times of activation (20, 40, and 60 seconds) were tested. Means and standard deviations were calculated and statistically analyzed with the Kruskal-Wallis and Wilcoxon tests (p0.05). Conclusions No significant differences were found between 5% sodium hypochlorite and 17% EDTA. When the time of activation rises, the dentin debris removal increases in all groups. Both sonic and ultrasonic activation demonstrate high capacity for dentin debris removal

    Going Beyond Counting First Authors in Author Co-citation Analysis

    Full text link
    The present study examines one of the fundamental aspects of author co-citation analysis (ACA) - the way co-citation counts are defined. Co-citation counting provides the data on which all subsequent statistical analyses and mappings are based, and we compare ACA results based on two different types of co-citation counting - the traditional type that only counts the first one among a cited work's authors on the one hand and a non-traditional type that takes into account the first 5 authors of a cited work on the other hand. Results indicate that the picture produced through this non-traditional author co-citation counting contains more coherent author groups and is therefore considerably clearer. However, this picture represents fewer specialties in the research field being studied than that produced through the traditional first-author co-citation counting when the same number of top-ranked authors is selected and analyzed. Reasons for these effects are discussed

    Variations on the Author

    Full text link
    “Variations on the Author” discusses two of Eduardo Coutinho’s recent films (Um Dia na Vida, from 2010, and Últimas Conversas, posthumously released in 2015) and their contribution to the general question of documentary authorship. The director’s filmography is characterized by a consistent yet self-effacing form of authorial self-inscription: Coutinho often features as an interviewer that rather than express opinions propels discourses; an interviewer that is good at listening. This mode of self-inscription characterizes him as an author who is not expressive but who is nonetheless markedly present on the screen. In Um Dia na Vida, however, Coutinho is completely absent form the image, while Últimas Conversas, on the contrary, includes a confessional prologue that moves the director from the margins to the center of his films. This article examines the ways in which these works stand out in the filmography of a director who offers new insights into the notion of cinematic authorship

    Appropriate Similarity Measures for Author Cocitation Analysis

    Full text link
    We provide a number of new insights into the methodological discussion about author cocitation analysis. We first argue that the use of the Pearson correlation for measuring the similarity between authors’ cocitation profiles is not very satisfactory. We then discuss what kind of similarity measures may be used as an alternative to the Pearson correlation. We consider three similarity measures in particular. One is the well-known cosine. The other two similarity measures have not been used before in the bibliometric literature. Finally, we show by means of an example that our findings have a high practical relevance.information science;Pearson correlation;cosine;similarity measure;author cocitation analysis

    Cyclic fatigue resistances of Hyflex EDM, WaveOne gold, Reciproc blue and 2shape NiTi rotary files in different artificial canals

    No full text
    The aim of the present study was to compare the cyclic fatigue resistances of HyFlex EDM (HEDM), WaveOne Gold (WOG), Reciproc Blue (RB), and 2Shape (TS) NiTi systems having different metallurgic properties. HEDM, WOG, RB, and TS instruments were rotated in artificial canals which were made of stainless steel with an inner diameter of 1.5 mm, 45°, and 90° angles of curvatures and a radius of curvature of 5 mm until fracture occurred, and the time to fracture (TTF) was recorded in seconds. Also, number of cycles to fracture was calculated (NCF). Data were statistically analyzed using Kruskal-Wallis and t test. The statistical significance level was set at P 0.05). When the NCF values were taken into consideration, HEDM reported a significantly higher cyclic fatigue resistance than TS in both canal curvatures analyzed (P < 0.05). Within the limitations of the present study, RB NiTi files showed statistically higher cyclic fatigue resistance in artificial canals with 45° and 90° than the other NiTi files tested

    Dispelling the Myths Behind First-author Citation Counts

    Full text link
    We conducted a full-scale evaluative citation analysis study of scholars in the XML research field to explore just how different from each other author rankings resulting from different citation counting methods actually are, and to demonstrate the capability of emerging data and tools on the Web in supporting more realistic citation counting methods. Our results contest some common arguments for the continued use of first-author citation counts in the evaluation of scholars, such as high correlations between author rankings by first-author citation counts and other citation counting methods, and high costs of using more realistic citation counting methods that are not well-supported by the ISI databases. It is argued that increasingly available digital full text research papers make it possible for citation analysis studies to go beyond what the ISI databases have directly supported and to employ more sophisticated methods
    corecore