63,053 research outputs found

    A 2 h periodic variation in the low-mass X-ray binary Ser X-1

    No full text
    Spectroscopy of the low-mass X-ray binary Ser X-1 using the Gran Telescopio Canarias have revealed a ?2 h periodic variability that is present in the three strongest emission lines. We tentatively interpret this variability as due to orbital motion, making it the first indication of the orbital period of Ser X-1. Together with the fact that the emission lines are remarkably narrow, but still resolved, we show that a main-sequence K dwarf together with a canonical 1.4 M? neutron star gives a good description of the system. In this scenario, the most likely place for the emission lines to arise is the accretion disc, instead of a localized region in the binary (such as the irradiated surface or the stream-impact point), and their narrowness is due instead to the low inclination (?10°) of Ser X-1

    Effects of different levels of pressure support variability in experimental lung injury.

    No full text
    BACKGROUND: Noisy pressure support ventilation has been reported to improve respiratory function compared to conventional assisted mechanical ventilation. We aimed at determining the optimal level of pressure support variability during noisy pressure support ventilation. METHODS: Twelve pigs were anesthetized and mechanically ventilated. Acute lung injury was induced by surfactant depletion. At four levels of pressure support variability (coefficients of variation of pressure support equal to 7.5, 15, 30, and 45%, 30 min each, crossover design, special Latin squares sequence), we measured respiratory variables, gas exchange, hemodynamics, inspiratory effort, and comfort of breathing. The mean level of tidal volume was constant among variability levels. RESULTS: Compared to conventional pressure support ventilation, different levels of variability in pressure support improved the elastance of the respiratory system, peak airway pressure, oxygenation, and intrapulmonary shunt. Oxygenation and venous admixture benefited more from intermediate (30%) levels of variability, whereas elastance and peak airway pressure improved linearly with increasing variability. Heart rate as well as mean arterial and pulmonary arterial pressures decreased slightly at intermediate to high (30-45%) levels of variability in pressure support. Inspiratory effort and comfort of breathing were not importantly influenced by increased variability in pressure support. CONCLUSION: In a surfactant depletion model of acute lung injury, variability of pressure support improves lung function. The variability level of 30% seems to represent a reasonable compromise to improve lung functional variables during noisy pressure support ventilation

    Effects of Intravascular Volume Replacement on Lung and Kidney Function and Damage in Nonseptic Experimental Lung Injury

    No full text
    Abstract BACKGROUND: Intravascular volume replacement is often required in the presence of increased pulmonary capillary leakage, for example in patients with volutrauma with major hemorrhage. In the present study, the effects of Ringer's acetate (RA), gelatin-polysuccinate (GEL), and a modern hydroxyethyl starch (HES, 6% 130/0.42) on lung and kidney function and damage were compared in a two-hit model of acute lung injury. The authors hypothesized that GEL and HES, compared to RA: (1) reduced lung histological damage, (2) impaired kidney morphology and function. METHODS: Acute lung injury was induced in 30 anesthetized pigs by tidal volumes approximately 40 ml/kg, after saline lung lavage. Protective ventilation was initiated and approximately≈25% of estimated blood volume was drawn. Animals were randomly assigned to receive RA, GEL, or HES (n = 10/group) aimed at approximately 90% of intrathoracic blood volume before blood drainage. RESULTS: Fluid volumes were higher with RA (2,250 ± 764 ml) than GEL (704 ± 159 ml) and HES (837 ± 82 ml) (P < 0.05). Compared to RA, HES reduced diffuse alveolar damage overall, and GEL in nondependent zones only. GEL and HES yielded lower wet-to-dry ratios compared to RA (6.5 ± 0.5 and 6.5 ± 0.6 vs. 7.9 ± 0.9, respectively, P < 0.05). HES and RA resulted in less kidney damage than GEL, but kidney function did not differ significantly among groups. Compared to GEL, HES yielded lower lung elastance (55 ± 12 vs. 45 ± 13 cm H2O/l, P < 0.05) and intra-abdominal pressure (15 ± 5 vs. 11 ± 4 cm 14;H2O, P < 0.05). CONCLUSIONS: In this model of acute lung injury, intravascular volume expansion after major hemorrhage with HES yielded less lung damage than RA and less kidney damage than GEL

    Distribution of regional lung aeration and perfusion during conventional and noisy pressure support ventilation in experimental lung injury

    No full text
    Abstract In acute lung injury (ALI), pressure support ventilation (PSV) may improve oxygenation compared with pressure-controlled ventilation (PCV), and benefit from random variation of pressure support (noisy PSV). We investigated the effects of PCV, PSV, and noisy PSV on gas exchange as well as the distribution of lung aeration and perfusion in 12 pigs with ALI induced by saline lung lavage in supine position. After injury, animals were mechanically ventilated with PCV, PSV, and noisy PSV for 1 h/mode in random sequence. The driving pressure was set to a mean tidal volume of 6 ml/kg and positive end-expiratory pressure to 8 cmH2O in all modes. Functional variables were measured, and the distribution of lung aeration was determined by static and dynamic computed tomography (CT), whereas the distribution of pulmonary blood flow (PBF) was determined by intravenously administered fluorescent microspheres. PSV and noisy PSV improved oxygenation and reduced venous admixture compared with PCV. Mechanical ventilation with PSV and noisy PSV did not decrease nonaerated areas but led to a redistribution of PBF from dorsal to ventral lung regions and reduced tidal reaeration and hyperinflation compared with PCV. Noisy PSV further improved oxygenation and redistributed PBF from caudal to cranial lung regions compared with conventional PSV. We conclude that assisted ventilation with PSV and noisy PSV improves oxygenation compared with PCV through redistribution of PBF from dependent to nondependent zones without lung recruitment. Random variation of pressure support further redistributes PBF and improves oxygenation compared with conventional PSV

    Stable voters in an unstable party environment : continuity and change in Italian electoral behaviour

    No full text
    M.24981-1999 Paolo Segatti, Paolo Bellucci and Marco Maraffi. 30 cm. A previous version of this paper was presented at a symposium on Political Parties : Changing Roles in Contemporary Democracies, held at the Center for Advanced Study in the Social Sciences of the Juan March Institute, Madrid, December 15-17, 1994. -- P.1. Includes bibliographical references (p. 56-59

    De Maiestate / Praeside M. Jacobo Thomasio, Moralis Philosoph. P. P., publice disputabit Johannes Dunte, R. L. Author & Respon: ad diem 9. Septembr. H L. Q. C.

    No full text
    DE MAIESTATE / PRAESIDE M. JACOBO THOMASIO, MORALIS PHILOSOPH. P. P., PUBLICE DISPUTABIT JOHANNES DUNTE, R. L. AUTHOR & RESPON: AD DIEM 9. SEPTEMBR. H L. Q. C. De Maiestate / Praeside M. Jacobo Thomasio, Moralis Philosoph. P. P., publice disputabit Johannes Dunte, R. L. Author & Respon: ad diem 9. Septembr. H L. Q. C. (1) Titelblatt (1) Widmung (2) Text (3) Beiträge (21

    A novel adaptive control system for noisy pressure-controlled ventilation: a numerical simulation and bench test study.

    No full text
    PURPOSE: There is growing interest in the use of both variable and pressure-controlled ventilation (PCV). The combination of these approaches as "noisy PCV" requires adaptation of the mechanical ventilator to the respiratory system mechanics. Thus, we developed and evaluated a new control system based on the least-mean-squares adaptive approach, which automatically and continuously adjusts the driving pressure during PCV to achieve the desired variability pattern of tidal volume (V (T)). METHODS: The controller was tested during numerical simulations and with a physical model reproducing the mechanical properties of the respiratory system. We applied step changes in respiratory system mechanics and mechanical ventilation settings. The time needed to converge to the desired V (T) variability pattern after each change (t (c)) and the difference in minute ventilation between the measured and target pattern of V (T) (DeltaMV) were determined. RESULTS: During numerical simulations, the control system for noisy PCV achieved the desired variable V (T) pattern in less than 30 respiratory cycles, with limited influence of the dynamic elastance (E*) on t (c), except when E* was underestimated by >25%. We also found that, during tests in the physical model, the control system converged in <60 respiratory cycles and was not influenced by airways resistance. In all measurements, the absolute value of DeltaMV was <25%. CONCLUSION: The new control system for noisy PCV can prove useful for controlled mechanical ventilation in the intensive care unit
    corecore