34 research outputs found
New technologies in breast cancer sentinel lymph node biopsy; from the current gold standard to artificial intelligence
Sentinel lymph node biopsy is an important diagnostic procedure performed in early breast cancer patients with clinically negative axillary lymph nodes. Detection and examination of sentinel lymph nodes determine further therapy decisions, therefore a choice of optimal technique minimising the risk of false-negative results is of great importance. Currently, the gold standard is the dual technique comprising the blue dye and radiotracer, however, this method creates a logistical problem for many medical units. The intrinsic constraints of the existing methods led to the development of a very wide range of alternatives with varying clinical efficiency and feasibility. While each method presents with its own advantages and disadvantages, many techniques have improved enough to become a non-inferior alternative in the sentinel lymph node biopsy. Along with the improvement of the existing technologies, there are evolving trends such as multimodality of the techniques maximising the diagnostic outcome or an emerging use of artificial intelligence (AI) improving the workflow of the procedure. This literature review aims to give an overview of the current status of the standard techniques and emerging cutting-edge technologies in the sentinel lymph node biopsy
Fluorescence Imaging Using Methylene Blue Sentinel Lymph Node Biopsy in Melanoma
Introduction: Fluorescence imaging of sentinel node biopsy in melanoma is a novel method. Both indocyanine green (ICG) and methylene blue (MB) have fluorescent properties. The aim of this study was to present, for the first time in a clinical series of patients, the possible usage of MB as a fluorescent dye for sentinel node biopsy during surgery for melanoma. Material and methods: Twenty patients with skin melanoma, who were candidates for sentinel node biopsy were enrolled in our study. All patients underwent simultaneous use of standard nanocolloid and blue dye. Transcutaneous visualization of the sentinel node, visualization of lymphatic channels as well as sentinel node fluorescent visualization were all measured. We also performed calculations of Signal to Background ratios (SBR). Results: In 15% (3/20) of patients, the fluorescent sentinel node was visible through the skin. The median SBR for the sentinel node visualization by fluorescence was 3.15 (range, 2.7–3.5). Lymphatic channels were visible in lymphatic tissue via fluorescence before visualization by the naked eye in 4 patients (20%). The median SBR ratio was 3.69 (range, 2.7–4.2). Sentinel nodes were visible by fluorescence in 13 cases (65%). The median SBR ratio was 2.49 (range, 1.5–5.7). No factors were found to be associated with fluorescent MB visualization of a sentinel node during biopsy. Conclusion: This is the first clinical study presenting the usefulness of fluorescent sentinel node biopsy in melanoma patients using MB as a fluorophore. Further studies are necessary to provide methods for its’ clinical implementation. © The Author(s) 2022
SUN-LB323: Completely Laparoscopic Feeding Jejunostomy – Own Surgical Technique Modification and Results of a Pilot Group
Evaluating Postoperative Morbidity and Outcomes of Robotic-Assisted Esophagectomy in Esophageal Cancer Treatment—A Comprehensive Review on Behalf of TROGSS (The Robotic Global Surgical Society) and EFISDS (European Federation International Society for Digestive Surgery) Joint Working Group
Background: Esophageal cancer, the seventh most common malignancy globally, requires esophagectomy for curative treatment. However, esophagectomy is associated with high postoperative morbidity and mortality, highlighting the need for minimally invasive approaches. Robotic-assisted surgery has emerged as a promising alternative to traditional open and minimally invasive esophagectomy (MIE), offering potential benefits in improving clinical and oncological outcomes. This review aims to assess the postoperative morbidity and outcomes of robotic surgery. Methods: A comprehensive review of the current literature was conducted, focusing on studies evaluating the role of robotic-assisted surgery in esophagectomy. Data were synthesized on the clinical outcomes, including postoperative complications, survival rates, and recovery time, as well as technological advancements in robotic surgery platforms. Studies comparing robotic-assisted esophagectomy with traditional approaches were analyzed to determine the potential advantages of robotic systems in improving surgical precision and patient outcomes. Results: Robotic-assisted esophagectomy (RAMIE) has shown significant improvements in clinical outcomes compared to open surgery and MIE, including reduced postoperative pain, less blood loss, and faster recovery. RAMIE offers enhanced thoracic access, with fewer complications than thoracotomy. The RACE technique has improved patient recovery and reduced morbidity. Fluorescence-guided technologies, including near-infrared fluorescence (NIRF), have proven valuable for sentinel node biopsy, lymphatic mapping, and angiography, helping identify critical structures and minimizing complications like anastomotic leakage and chylothorax. Despite these benefits, challenges such as the high cost of robotic systems and limited long-term data hinder broader adoption. Hybrid approaches, combining robotic and open techniques, remain common in clinical practice. Conclusions: Robotic-assisted esophagectomy offers promising advantages, including enhanced precision, reduced complications, and faster recovery, but challenges related to cost, accessibility, and evidence gaps must be addressed. The hybrid approach remains a valuable option in select clinical scenarios. Continued research, including large-scale randomized controlled trials, is necessary to further establish the role of robotic surgery as the standard treatment for resectable esophageal cancer
Test sequence for superconducting XFEL Cavities in the Accelerator Module Test Facility (AMTF) at DESY
The European XFEL is a new research facility currently under construction at DESY in the Hamburg area in Germany. From 2016 on, it will generate extremely intense X-ray flashes that will be used by researchers from all over the world. The main part of the superconducting European XFEL linear accelerator consists of 100 accelerator modules with 800 RF-cavities inside. The accelerator modules, superconducting magnets and cavities will be tested in the accelerator module test facility (AMTF) at DESY. This paper gives an overview of the test sequences for the superconducting cavities, applied in the preparation area and at the two cryostats (XATC) of the AMTF-hall, and describes the complete area. In addition it summarizes the tests and lessons learnt until the middle of 2014.© 2014 The Authors. Published by Elsevier B.V.Peer-review under responsibility of the organizing committee of ICEC 25-ICMC 2014
J-PARC Neutrino Beamline Upgrade Technical Design Report
In this document, technical details of the upgrade plan of the J-PARC neutrino beamline for the extension of the T2K experiment are described. T2K has proposed to accumulate data corresponding to protons-on-target in the next decade, aiming at an initial observation of CP violation with or higher significance in the case of maximal CP violation. Methods to increase the neutrino beam intensity, which are necessary to achieve the proposed data increase, are described
J-PARC Neutrino Beamline Upgrade Technical Design Report
International audienceIn this document, technical details of the upgrade plan of the J-PARC neutrino beamline for the extension of the T2K experiment are described. T2K has proposed to accumulate data corresponding to protons-on-target in the next decade, aiming at an initial observation of CP violation with or higher significance in the case of maximal CP violation. Methods to increase the neutrino beam intensity, which are necessary to achieve the proposed data increase, are described
J-PARC Neutrino Beamline Upgrade Technical Design Report
International audienceIn this document, technical details of the upgrade plan of the J-PARC neutrino beamline for the extension of the T2K experiment are described. T2K has proposed to accumulate data corresponding to protons-on-target in the next decade, aiming at an initial observation of CP violation with or higher significance in the case of maximal CP violation. Methods to increase the neutrino beam intensity, which are necessary to achieve the proposed data increase, are described
J-PARC Neutrino Beamline Upgrade Technical Design Report [Elektronisk resurs]
In this document, technical details of the upgrade plan of the J-PARC neutrino beamline for the extension of the T2K experiment are described. T2K has proposed to accumulate data corresponding to 2×1022 protons-on-target in the next decade, aiming at an initial observation of CP violation with 3σ or higher significance in the case of maximal CP violation. Methods to increase the neutrino beam intensity, which are necessary to achieve the proposed data increase, are described.AuthorOverflow(384
The T2K experiment
The T2K experiment is a long baseline neutrino oscillation experiment. Its main goal is to measure the last unknown lepton sector mixing angle θ13 by observing νe appearance in a νμ beam. It also aims to make a precision measurement of the known oscillation parameters, and sin22θ23, via νμ disappearance studies. Other goals of the experiment include various neutrino cross-section measurements and sterile neutrino searches. The experiment uses an intense proton beam generated by the J-PARC accelerator in Tokai, Japan, and is composed of a neutrino beamline, a near detector complex (ND280), and a far detector (Super-Kamiokande) located 295 km away from J-PARC. This paper provides a comprehensive review of the instrumentation aspect of the T2K experiment and a summary of the vital information for each subsystem
