28 research outputs found

    PERBEDAAN INFORMASI CITRA ANATOMI MRI GENU PADA APLIKASI SHORT TE (STE) DAN ULTRASHORT TE (UTE) (STUDI KOMPARASI CITRA MRI GENU PEMBOBOTAN T1WI TURBO SPIN ECHO (TSE)).

    No full text
    ABSTRACTBackgroud: Ultrashort time echo (UTE) is a pulse sequence that aims to detect signals from tissues with short T2 values using TE values smaller than conventional TE on T1WI, whereas the TE in UTE ranges from 0,07 ms to 10 ms. This study aimed to determine the differences of anatomical information by using T1WI TSE STE and T1WI TSE UTE on knee MRI examination, so later on this research it will be known which image weighting produce the most optimal image information, therefore the author wanted to study it further and compile it in scientific papers titled " The Anatomical Information Differences Between The Application Of Short TE (STE) And Ultrashot TE (UTE) On Knee MRI (A Comparative Study On Knee MRI Images With T1WI Turbo Spin Echo (TSE)).Methods: This study is quantitative study with experimental approach. It was conducted at Rumah Sakit Umum Daerah Badung (Badung General Hospital), Bali. The data are T1WI TSE images of knee MRI in sagittal slices from 30 patients each from the application of Short TE (STE) and Ultrashort TE (UTE). The data assessment was done by two respondents and the analysis was done by Wilcoxon sign rank test. Results: The result showed that there was a difference on anatomical information of knee MRI in sagital slices between the application of T1WI TSE STE and T1WI TSE UTE with significance value (p value

    PENGEMBANGAN ALAT DAN UJI KESESUAIAN KOLIMATOR PESAWAT SINAR-X (DEV-X) BERBASIS TEKNOLOGI PEMROGRAMAN ANDROID CITRA DIGITAL

    No full text
    Latar Belakang : Perkembangan teknologi khususnya dibidang radiologi berkembang pesat. System penjamin mutu alat radiologi pun ikut berkembang salah satunya Collimator Test Tools. Metode pengujian berkas sinar-x menggunakan alat ini pun banyak di kembangkan seperti menggunakan film dan menggunakan IP. Perkembangan Collimator Test Tools dengan memanfaatkan sifat sinar-x yang menyebabkan bahan-bahan tertentu seperti kalsium tungstat atau zink sulfide memendarkan cahaya (luminisensi) banyak di lakukan namun kajian dari produk tersebut belum ada.Tujuan : Terciptanya alat collimator test tools pesawat sinar-x berbasis teknologi analisis citra digital (Dev-X) dan kamera digital serta aplikasi (Dev-X) pada smartphone yang hasil pengukuran luas lapangan berkas sinar-x nya akan sesuai dengan hasil pengukuran luas pandang menggunakan alat ukur collimator test tool berbasis citra analog (TOR ABC).Metode : Jenis penelitian experimental dengan rancangan true experimental dengan mengembangkan suatu metode yang sudah ada dengan cara membuat rancang bangun dan melakukan uji fungsi collimator test tool berbasis teknologi analisis citra digital (Dev-X), dengan tipe posttest group only design. Lokasi Penelitian di Laboratorium Radiologi Akademi Teknik Radiodiagnostik dan Radioterapi (ATRO) Bali.Hasil : Uji Fungsional Produk Dev-X (hardware dan software), seluruh komponen berfungsi dengan baik. Hasil perbandingan nilai kesesuaian kolimator antara produk Dev-X dengan TOR ABC pada nilai ?X dan ?Y ? 2% (2 cm) sama-sama memberikan nilai kesesuaian ? 2% (2 cm) pada FFD. Nilai ?X+?Y? 3% (3 cm) pada FFD antara produk Dev-X dengan TOR ABC 2.3 cm atau ? 3% (3 cm) pada FFD. tidak ada perbedaan hasil ?X, ?Y dan ?X+?Y dari masing-masing alat. Namun belum dapat dinilai secara signifikan dari hasil statistik. Kesimpulan : Tercipta dan Berfungsinya hardware dan software alat collimator test tool Dev-X pada smartphone android dan menampilkan hasil perhitungan berkas sinar-x secara otomatis. Sesuainya hasil pengukuran luas lapangan berkas sinar-x antara alat collimator test tools pesawat sinar-x berbasis teknologi analisis citra digital (Dev-X) dengan citra analog (TOR ABC) di Laboratorium Radiologi Akademi Teknik Radiodiagnostik dan Radioterapi (ATRO) Bali

    JAMINAN MUTU PESAWAT CT SCAN SINGLE SLICE DI UNIT RADIOLOGI RSU SEMARA RATIH

    No full text
    Latar Belakang: Pesawat CT Scan single slice Merk SIEMENS/Dura 302 MV di unit Radiologi Rumah Sakit Umum Semara Ratih Kabupaten Tabanan Bali terpasang pada bulan Nopember 2020 merupakan alat second hand dengan tahun produksi 2012. Pelaksanaan kendali dilakukan pada saat penerimaan (acceptance test) meliputi pengujian terhadap indeks dosis  CT (CTDI) untuk  kepala, indeks dosis  CT (CTDI untuk badan, CT-Number udara, kesesuaian table slice dengan setting semua slice, indikator posisi meja (sumbu z), laser penanda dan pada bulan april 2021 yang dilakukan oleh Badan Pengawas Fasilitas Kesehatan (BPFK) Surabaya meliputi uji teknis generator dan tabung sinar-X (uji akurasi tegangan tabung, uji kualitas berkas sinar-X), uji kualitas citra (uji akurasi CT number air, keseragaman CT number), dan pelaksanaan kendali mutu rutin peralatan radiologi jarang dilaksanakan secara berkesinambungan untuk menjaga kinerja pesawat CT Scan. Metode penelitian: kualitatif deskriptif dengan pendekatan survey. Hasil dan Pembahasan: Pengujian yang telah dilakukan diperoleh nilai rata rata CT number untuk water phantom pada lima posisi yang berbeda adalah -1,68; -0,76; -2,21; -1,77; -1,53 HU dan semua berada pada rentang nilai toleransinya yaitu -4 sampai 4 HU. Pengujian Dry laser printer dengan dengan hasil sebagaian besar masih sesuai parameter uji yang berlaku, hanya pada pattern 0% terdapat nilai uji yang melebihi standar artinya quality control untuk Dry laser printer di Unit Radiologi RSU Semara Ratih tidak sasuai dengan standar sehingga di perlukan kalibrasi. Pada Pengujian form check list yang telah dilakukan di Unit Radiologi RSU Semara Ratih untuk mengetahui ada tidak nya  tombol alat yang tidak berfungsi dengan hasil semua fungsi dan tombol masih berfungi dengan baik. Kesimpulan: Hasil uji kesesuaian pada Pesawat CT Scan single slice Merk SIEMENS/Dura 302 MV di unit Radiologi Rumah Sakit Umum Semara Ratih Kabupaten Tabanan Bali dalam batas normal kecuali pada dry laser printer

    Analisis Pemeriksaan CT Scan Urografi pada Klinis Hidronefrosis di RS Tk Ii Pelamonia Makassar

    No full text
    CT Urography is a diagnostic imaging technique used to evaluate the urinary tract system, including the kidneys, ureters, and bladder. This study aims to analyze CT Urography examinations in patients with clinical hydronephrosis at RS TK II Pelamonia Makassar to assess the effectiveness of imaging techniques in detecting obstructions, kidney stones, tumors, and the severity of the condition. The research method used is descriptive qualitative with a case study approach. Data were collected through observations, interviews, and documentation. The study results indicate that CT Urography examination with a slice thickness of 5 mm provides clear visualization of hydronephrosis conditions. The examination procedure at RS TK II Pelamonia Makassar follows standard operating procedures (SOP), although slight differences in imaging parameters were observed compared to theoretical guidelines. In conclusion, CT Urography is an effective imaging modality for detecting hydronephrosis pathology and assists in making more accurate medical decisions. &nbsp

    Optimalisasi Nilai CNR Perbandingan Aplikasi Short TE (STE) dan Ultrashort TE (UTE): Studi Komparasi Citra MRI Genu Pembobotan T1wi Turbo Spin Echo (TSE) di Instalasi Radiologi Rumah Sakit Daerah Mangusada Badung: Optimization Of Cnr Value With Application Comparison Short TE (STE) and Ultrashort TE (UTE): Comparative Study of Genu MRI Images Weighted T1wi Turbo Spin Echo (TSE) in The Radiology Installation of Mangusada Regional Hospital Badung

    No full text
    Sendi Lutut merupakan sendi terbesar dan paling kompleks pada tubuh manusia yang terdiri dari Anterior Cruciate Ligament, Posterior Cruciate Ligament, dan patella tendon. Salah satu parameter MRI adalah TE. Short TE (STE) mengacu pada teknik pencitraan MRI yang menggunakan TE yang relatif singkat. Ultrashort TE (UTE) menggunakan TE yang sangat pendek dan memungkinkan pencitraan struktur seperti tendon dan tulang kortikal. Jenis penelitian yang digunakan adalah kuantitatif dengan pendekatan studi eksperimen. Penelitian dilakukan di Instalasi Radiologi RS Mangusada Badung dengan rasio STE dan UTE dengan nilai TE 16 ms dan 0,8 ms. Pengukuran CNR dilakukan pada area yang akan dievaluasi yaitu anatomi Anterior Cruciate Ligament dan Posterior Cruciate Ligament. Hasil penelitian menunjukkan CNR citra MRI Genu potongan sagital antara aplikasi T1WI TSE STE dan T1WI TSE UTE dengan p-value signifikan <0,05. Hasilnya perbandingan CNR optimal antara aplikasi STE dan UTE adalah variasi UTE dengan nilai mean rank 16,67 untuk ACL dan 11,05 untuk PCL. Dari hasil uji beda Wilcoxon tiap variasi diperoleh p-value ACL 0,016, PCL 0,008, p-value keseluruhan 0,005 sehingga terdapat perbedaan. Uji Wilcoxon mean rank kualitas gambar mean rank tertinggi diperoleh dari UTE, sehingga UTE mampu menghasilkan CNR pada organ yang optimal dibandingkan dengan STE

    Analisis Verifikasi Geometri Menggunakan EPID (Electronic Portal Imaging Device) Pada Penderita Kanker Cervix Yang Menjalani Terapi Radiasi Dengan Teknik 3DCRT Di Sub Instalasi Radioterapi RSUP Prof Dr. I. G. N. G Ngoerah

    No full text
    One of the cancers that causes the highest mortality is nasopharyngeal cancer. The number of nasopharyngeal cancer cases in Indonesia reached 19,943 new cases with a mortality rate of 13,399. Radiotherapy is the main treatment modality and part of standard care for cancer patients. The way radiotherapy works is to damage the DNA chain of tumor cells in order to kill tumor cells directly and eliminate the ability to proliferate. Giving radiation to the head and neck region has an influence on weight loss. The purpose of this study was to describe the BMI (Body Mass Index) of nasopharyngeal cancer patients who underwent IMRT therapy at the Radiotherapy Unit of Prof. Dr. I.G.N.G Ngoerah Hospital. The type of research used is quantitative research with an observational approach using retrospective data. The samples of this study were 25 patients with nasopharyngeal cancer who underwent IMRT therapy from January to December 2021 at the Radiotherapy Unit of Prof. Dr. I.G.N.G Ngoerah Hospital. The results of this study showed 25 samples of nasopharyngeal cancer patients who underwent IMRT therapy experienced weight loss with an average of 13.01 and BMI with an average of 4.93. Based on the results of the Statistical Test which shows that the p value <0.05 which means there is a decrease in body weight in nasopharyngeal cancer patients undergoing IMRT therapy in the Radiotherapy Unit of Prof. Dr. I.G.N.G Ngoerah Hospital. Of the 25 samples of nasopharyngeal cancer patients who underwent IMRT therapy, there were changes in BMI (Body Mass Index) before irradiation and after irradiation. This is evident from the normality test value and Paired Twhich shows a p value <0.05, meaning that there is a decrease in body weight in nasopharyngeal cancer patients undergoing IMRT therapy. &nbsp

    ANALISIS KARAKTERISTIK NILAI APPARENT DIFFUSION COEFFICIENT (ADC) PADA AXIAL DWI MRI KNEE JOINT DI RUMAH SAKIT BALIMED DENPASAR

    No full text
    Abstrak: Analisis Karakteristik Nilai Apparent Diffusion Coefficient (ADC) Pada Axial DWI MRI Knee Joint Di Rumah Sakit Balimed Denpasar. Latar Belakang: Penilaian berbagai kondisi musculoskeletal dengan menerapkan Diffusion Weighted Imaging (DWI) dalam penerapannya DWI memiliki parameter penting yang dapat digunakan dalam membantu menentukan patologi dan diagnosis pengukuran neoplasma yaitu ADC value. Pengukuran ADC yang tinggi menunjukkan peningkatan gerakan air ekstraseluler, serta hilangnya integritas membran sel, sedangkan nilai ADC yang rendah menunjukkan penurunan air ekstraseluler atau selularitas tinggi, sehingga ADC ini sangat berkaitan dengan derajat keganasan. Metode: Penelitian ini merupakan penelitian kuantitatif deskriptif dengan pendekatan survey untuk mengevaluasi karakteristik nilai ADC pada axial DWI pemeriksaan MRI Knee Joint. Data ADC yang di dapat dimasukan ke dalam worksheet Microsoft Excel dan diolah dengan menggunakan program Microsoft Excel, selanjutnya analisa data dilakukan secara deskriptif untuk dapat menampilkan sebaran serta karakteristik nilai ADC pada potongan axial yang telah dikumpulkan. Hasil: Hasil dari 12 sampel yang terkumpul pada penelitian ini, dapat dikategorikan menjadi beberapa kelompok patologi, yaitu kelompok patologi Trauma atau Injury termasuk didalamnya berupa patologi pada kartilago, ligamen, maupun Trauma pada tulang, Patologi Lesi yaitu Kista/Cyst dan Lymphoma, serta kelompok patologi Oedema. Dari 3 kelompok kategori patologi tersebut terdapat peningkatan nilai ADC yang bervariasi. Kesimpulan: Penggunaan DWI dan nilai ADC dalam pemeriksaan MRI knee joint dapat membantu dalam mengidentifikasi dan membedakan berbagai jenis patologi, sehingga memungkinkan penanganan yang lebih tepat dan akurat. Dalam tiga kelompok yang ditemukan, karakteristik ketiga kelompok menunjukkan peningkatan nilai ADC baik pada patologi Trauma non infeksi, lesi, serta oedema. Peningkatan nilai ADC pada Ketiga kelompok tersebut diakibatkan peningkatan tingkat difusi pada jaringan yang mengalami kelainan (trauma non infeksi dan lesi) serta akumulasi cairan baik pada ruang ekstraseluler maupun ruang sendi

    PERFORMANCE TEST OF MAGNETIC RESONANCE IMAGING MACHINE 0,35 TESLA AT KASIH IBU HOSPITAL SABA

    No full text
    Background: This research on the performance testing of the Magnetic Resonance Imaging (MRI) machine was conducted using performance tests on three different parameters at Kasih Ibu Hospital Saba. This research aims to determine the performance of the MRI machine at Kasih Ibu Hospital Saba in Bali Province and establish baseline data for future testing. Method: This type of research is quantitative and uses a survey approach. The tools and materials used in this study are a 0.35 Tesla MRI machine, an ACR phantom, and a head coil. Data were collected by conducting nine MRI performance testing procedures using the ACR (2015) guidelines and then analyzed using international standards issued by ACR (2015). Result: In the visual checklist testing, all observed parameters were over 30 days and functioned well, For the Artifact Evaluation test, the author evaluated all scanned images and found no artifacts. The author analyzed the measurements from the first slice of T1W and T2W images for the Slice Thickness Accuracy test. The measurement results for the T1W image were 4.6mm, and for the T2W image, they were 5.57mm. The Slice Thickness Accuracy testing standard set by ACR in 2015 is 5mm ± 0.7mm. Therefore, based on the measurement results from the T1W and T2W images, the MRI machine at Kasih Ibu Saba Hospital meets the established international standards. Conclusion: Based on the results of the visual checklist test, the following results were obtained: all parameters on the visual checklist functioned well during the 30-day observation. Meanwhile, the two tests conducted with the phantom on the MRI machine at Kasih Ibu Hospital Saba the following results are: the artifact evaluation test and the slice thickness accuracy test met the international standards set by ACR in 2015

    PERBEDAAN INFORMASI ANATOMI ACL MRI KNEE JOINT T2W TSE DENGAN T2*GRE PADA POTONGAN SAGITAL DENGAN KASUS RUPTUR ACL DI INSTALASI RADIOLOGI RSUD PROVINSI NUSA TENGGARA BARAT

    No full text
    Protokol Survey_Full, Survey_Right, T2W_TSE_Tra, T2W_TSE_tra, T2W_TSE_Sag, T2W_SPIR, T1W_TSE_sag, T2W_TSE_sag, T2W_SPIR_cor sering digunakan untuk pemeriksaan MRI Knee Joint di RSUD Provinsi NTB, di Instalasi Radiologi RSUD Provinsi Nusa Tenggara Barat sekuens T2*GRE tidak menjadi sekuens rutin, sehingga penulis tertarik ingin membandingan hasil citra MRI Knee Joint T2W TSE dengan T2*GRE pada kasus ruptur ACL. Jenis penelitian ini adalah kuantitatif deskriptif. Penulis mengumpulkan data berupa 12 pasien hasil citra hasil radiograf dari pemeriksaan MRI Knee Joint terhadap 12 jumlah sampel pasien menggunakan sekuens T2W TSE dan T2*GRE Kemudian dari 12 hasil citra dilakukan penilaian berupa check list oleh responden yaitu 2 dokter radiolog. Data kemudian diolah dengan menggunakan spss. Hasil check list yang sudah diolah menggunakan spss, menurut hasil uji wilcoxon bahwa adanya perbedaan informasi anatomi ACL dengan sekuens T2W TSE dan T2*GRE sehingga diambil kesimpulan dengan hasil mean rank 2.00 jika sekuens T2W TSE lebih informatif dalam menilai anatomi ACL dari pada sekuens T2*GRE

    Analisis Perbedaan Sekuen 3D DIR pada MRI Brain Kasus Epilepsi (Studi Komparasi 3D T2 FLAIR SPACE) di Instalasi Radiologi RSUP Prof. Dr. I.G.N.G. Ngoerah

    No full text
    Background: Double Inversion Recovery (DIR) is a newer sequence compared to the T2 FLAIR sequence in MRI Brain examinations used for epilepsy cases. Further research is needed to determine the optimal sequence for MRI Brain in epilepsy cases.Methods: This research is a quantitative study with an experimental approach. This study uses DIR and T2 SPACE sekuen to assess image quality in terms of Contrast to Noise Ratio (CNR). The data will be analyzed using SPSS.Results: The normality test shows a p-value 0.05, indicating that the data is not normally distributed. In the Wilcoxon test, the negative rank indicates a decrease in image quality (CNR) from the DIR sequence to T2 FLAIR SPACE. The test statistics show a p-value 0.05, indicating a significant difference in image quality (CNR) between the DIR and T2 FLAIR SPACE sekuen.Conclusions: The Contrast to Noise Ratio (CNR) image quality in Double Inversion Recovery (DIR) is higher compared to T2 FLAIR SPACE, thus making the DIR sequence more optimal in assessing image quality (CNR) compared to the T2 FLAIR SPACE sequence