14 research outputs found
Isolation, nucleotide sequence, and physiological relevance of the gene encoding triose phosphate isomerase from Kluyveromyces lactis
Lack of triose phosphate isomerase activity (TIM) is of special interest because this enzyme works at an important branch point of glycolytic flux. In this paper, we report the cloning and sequencing of the Kluyveromyces lactis gene encoding TIM. Unlike Saccharomyces cerevisiae Delta TPI1 mutants, the K. lactis mutant strain was found to be able to grow on glucose. Preliminary bioconversion experiments indicated that, like the S. cerevisiae TIM-deficient strain, the K. lactis TIM-deficient strain is able to produce glycerol with high yield
Prognostic role of non-sustained ventricular tachycardia detected with remote interrogation in a pacemaker population
Background: Non-sustained ventricular tachycardia (NSVT) can occur asymptomatically and can be incidentally detected in the internal records of pacemakers (PM). The clinical value of NSVT in the population of PM patients is still uncertain. Our aim was to assess the prevalence of NSVT detected by remote PM control, to describe the clinical and demographic characteristics of patients with NSVT, and to assess the prognostic significance of NSVT in terms of both overall and cardiovascular mortality. Methods: Consecutive patients followed with PM remote interrogations from September 2010 to December 2015 were included. The transmissions pertaining to the first 12 months of remote control were analysed and the patients were divided by those presenting NSVT and those without NSVT. The two groups were compared in terms of total mortality and cardiovascular mortality based on the administrative data provided by the regional administration of the Italian National Health System. Results: The prevalence of NSVT in 408 patients (62% males, mean age 75.6; SD 10.6 years old) was 21% in a year. During a mean follow-up duration of 44 months, NSVT did not emerge as independently associated with overall mortality, but was associated with cardiovascular mortality in a competing risk regression model with older age, male gender, diabetes, chronic renal insufficiency, ischemic cardiomyopathy and chronic obstructive pulmonary disease. Conclusions: We show that NSVT episodes recorded by remote control in a PM population are independently associated with cardiovascular mortality with possible implications for risk stratification and therapeutic options
Contribuições para a análise do comportamento fluidodinâmico de um leito vibrofluidizado.
Vibro-fluidized beds with inert particles as fluidizing medium have been appearing as an innovative technique for drying of suspensions and pastes. Aiming to contribute for the comprehension of phenomena involved in such processes, an investigation of fluid dynamic behavior of a vibro-fluidized (and
also of a fluidized) bed with inert particles was carried out in this work. Glycerol was employed to wet the inert particles and then simulate the presence of a liquid paste into the bed. The purpose of the present work is to obtain a detailed
investigation of the effects of amplitude, frequency of vibration, dimensionless vibration number, degree of liquid saturation, and of the particle size and density on the fluid dynamic behavior of the bed. The research included also an
experimental investigation on the effects of the particle size distribution on the dynamic of inert particles into the fluidized, vibrated and vibro-fluidized beds, with an evaluation of size segregation patterns. The experiments were divided into three groups: in the first one, preliminary fluid dynamics tests were carried out; in the second one, the fluid dynamic behavior of fluidized and vibro-fluidized beds was investigated, and in
the last one, the effects of particle size distribution on the dynamics of fluidized, vibrated and vibro-fluidized beds were verified. The experimental apparatus used in the tests was a vibro-fluidized bed constituted of a glass chamber, with a 0.114 m diameter cylindrical section, thickness of 0.003 m and height of 0.50 m. Ballotini spherical glass beads (ρp =2,500 kg/m3), with mean diameters from 1.10x10-3 to 17.00x10-3 m,
polypropylene spheroids (ρp = 935 kg/m3) with mean diameters of 2.60x10-3 and 3.67x10-3 m and elliptical cylinders of polystyrene (ρp = 1,050 kg/m3) with equivalent diameter (volumetric diameter) of 2.51x10-3 m, were used as inert particles. The bed was operated under dimensionless vibration numbers from 0.00 to 6.00, for amplitudes varying from 0.000 to 0.021 and frequencies of vibration
from 0.00 and 18.20 Hz. Glycerol saturation degrees (defined as the ratio between volume of glycerol and volume of voids in the fixed bed) varied from 0.0000 and 0.0072. The glycerol was employed to simulate the presence of a liquid fed into
the bed in a batch mode, since it practically does not evaporate under the conditions of present work. Identical values of dimensionless vibration numbers (Γ) were obtained using different combinations of amplitudes (A) and frequencies
of vibration (f), aiming to verify the universality of such a parameter to describe vibration characteristics of a vibro-fluidized bed. Four types of size distribution models were used in the investigation of the effects of the particle size distribution on the dynamics of vibro-fluidized beds: binary, flat, Gaussian and a reference one, all of them with a mean Sauter diameter of 2.18x10-3 m. In the range of experimental conditions investigated, it was observed that the dimensionless vibration number does not fully characterize the fluid dynamic behavior of the vibrated systems. Some degree of particle agglomeration was always observed in the presence of glycerol, yielding to an irregular and poor fluidization. The use of vibration in such cases improved the
particle circulation in the bed, thus reducing the agglomeration and minimizing the formation of channelling.
When specific particle size distributions were adopted for fluidization, some size segregation pattern was observed in almost every case. In the fluidized bed, the smallest particles stayed at the top of the column, while in the vibrated
one the largest particles tended to concentrate at the top. In a vibro-fluidized bed under short amplitude of vibration (0.003 m), some segregation was noted but in a less extent than that observed in the fluidized bed at similar conditions. At high
amplitude of vibration (0.009 m), no size segregation was detected.Os leitos vibrofluidizados que utilizam partículas inertes como meio para fluidização estão se destacando como uma nova alternativa para a secagem de pastas e suspensões. A fim de contribuir para a compreensão dos fenômenos envolvidos neste processo, neste trabalho foi efetuada uma investigação do comportamento fluidodinâmico do leito vibrofluidizado (e fluidizado), constituído de partículas inertes e utilizando o glicerol para simular a presença de um líquido. O propósito desta pesquisa é efetuar uma investigação detalhada dos efeitos da amplitude, da freqüência, do adimensional de vibração, do grau de saturação de líquido, do tamanho e da densidade das partículas inertes sobre o comportamento
fluidodinâmico do leito. De forma complementar, realizar um estudo experimental da influência da distribuição granulométrica sobre o comportamento dinâmico das
partículas inertes no leito fluidizado, vibrado (sem escoamento de ar) e vibrofluidizado, avaliando-se também o fenômeno da segregação. Os experimentos foram divididos em três conjuntos: no primeiro realizou-se ensaios fluidodinâmicos preliminares; no segundo, analisou-se o comportamento fluidodinâmico do leito fluidizado e vibrofluidizado e, no terceiro, estudou-se o efeito da distribuição de partículas sobre a dinâmica dos leitos fluidizado, vibrado e vibrofluidizado.
O equipamento utilizado foi um leito vibrofluidizado composto por uma câmara de vidro, com seção circular de 0,114 m de diâmetro, 0,50 m de altura e 0,003 m de espessura. As partículas inertes utilizadas nos ensaios fluidodinâmicos
preliminares foram esferas de vidro do tipo ballotini (ρp = 2.500 kg/m3), com diâmetros médios entre 1,10x10-3 e 17,00x10-3 m, esferóides de polipropileno (ρp = 935 kg/m3) com diâmetros médios de 2,60x10-3 e 3,67x10-3 m e cilindros
elípticos de poliestireno (ρp = 1.050 kg/m3) com diâmetro equivalente (da esfera de mesmo volume) de 2,51x10-3 m. O leito foi operado com adimensionais de vibração entre 0,00 e 6,00, para amplitudes entre 0,000 e 0,021 m, freqüências entre 0,00 e 18,20 Hz e graus de saturação de glicerol (volume de glicerol por volume de poros no leito estático) entre 0,0000 e 0,0072. O glicerol foi utilizado para simular
a presença de líquido alimentado em batelada, uma vez que este praticamente não evapora nestas condições experimentais. Idênticos valores de adimensionais de
vibração (Γ) foram obtidos utilizando diferentes combinações entre amplitudes (A) e freqüências (f) de vibração, com o objetivo de verificar sua universalidade para descrever as características de vibração de um leito vibrofluidizado. No estudo do efeito da distribuição de partículas sobre a dinâmica do leito fluidizado, vibrado e vibrofluidizado, foram utilizadas quatro distribuições de partículas (binária, plana,
gaussiana e de referência), com diâmetros médios de Sauter de 2,18x10-3 m. No intervalo de condições experimentais utilizadas nos experimentos fluidodinâmicos, observou-se que isoladamente o adimensional de vibração não representou de maneira única o comportamento fluidodinâmico do sistema. Em
todos os casos onde estava presente o glicerol, constatou-se a ocorrência de algum nível de aglomeração das partículas, tornando a fluidização de má qualidade e irregular. A vibração nestes casos melhorou a movimentação das partículas,
minimizando a aglomeração e atenuando a formação de canais preferenciais. Quando foi empregada uma distribuição de partículas no leito, observou-se de uma forma global a ocorrência de segregação em quase todos os casos. No leito fluidizado, houve a migração das partículas menores para
parte superior do leito, no vibrado ocorreu a migração das partículas maiores para parte superior do leito. Para o leito vibrofluidizado submetido à uma baixa amplitude de vibração (0,003 m) houve segregação, mas em menor quantidade
que no leito fluidizado, enquanto que, quando submetido à alta amplitude de vibração (0,009 m), não ocorreu a segregação granulométrica
Estudo do processo de estampagem incremental em chapas de titânio comercialmente puro ASTM F-67 grau 2 / Study of the incremental sheet forming in sheets of commercially pure titanium ASTM F-67 grade 2
O presente trabalho tem como objetivo avaliar o comportamento da chapa de titânio puro ASTM F-67 grau 2 para o processo de estampagem incremental de chapas (ISF – Incremental Sheet Forming) baseado nos parâmetros: decida helicoidal da ferramenta, ângulo de parede (Ψ) e raio de canto. Os experimentos foram realizados utilizando a estampagem incremental de ponto simples. Foram realizados 18 experimentos no total, com os quais buscou-se alcançar o melhor ângulo de parede com decida helicoidal da ferramenta e avaliar a influência do raio de canto. O raio base utilizado foi de 20 mm, com este, buscou-se atingir o melhor ângulo de parede possível. A partir disto variou-se o raio para avaliar a influência deste na estampagem incremental. Para os experimentos foram utilizados os seguintes recursos: softwares CAD/CAM, centro de usinagem CNC com três eixos, matriz incremental, ferramenta de estampagem incremental com inserto de titânio e um dispositivo prensa chapas. Foram avaliados a rugosidade superficial Ra, as deformações verdadeiras (φ) e a variação de espessura. Os resultados mostram que a estratégia de descida helicoidal da ferramenta proporcionou aumento do ângulo de parede comparado com estudos já realizados nesta área; o raio de canto influencia no rompimento da peça durante a estampagem. Os índices de rugosidade ficaram dentro dos valores indicados para a fabricação de próteses de titânio
P1634Clinical significance of the incidental detection of non-sustained ventricular tachycardia with remote monitoring of the pacemaker
Análise do desempenho do leito vibrofluidizado na secagem de pasta
The agitation promoted by the vibrofluidized bed allows the incorporation of several unitary operations such as granulation, coating of particle, drying of grains, and the drying of pasty materials. However, it is necessary more studies about the drying of paste in this equipment, since according to the work of Daleffe (2005) and Meili (2009) it was verified that a same dimensionless vibration number (Γ) presented different dynamics behaviors and influenced in distinct ways in the process. To understand more about the interference that the vibrational parameters may exert in this type of operation, that the goal of this present work was to develop a more detailed study on the drying of skimmed milk in vibrofluidized bed, varying the intensities of agitation imposed to the bed, two Amplitude (A) from 0.003m and 0.015m combined at frequencies (f) ranging from 100 to 1100 RPM. Thus, firstly, it was analyzed the influence that the vibrational parameters exercised on the characteristic curves of the pressure drop and the standard deviation of pressure drop in function of the superficial velocity of the fluid (Us), when the bed was constituted with glass beads with the diameters of 0.00119m, 0.00219m, and 0.00319m. Thereafter, water evaporation tests were performed to determine the size of the inert material and the experimental conditions that would be used in the paste drying trials. For the drying of the skimmed milk has been used glass beads with 0.00319m of average diameter, air temperature of 100 ° C, surface velocity of 20% higher than minimum fluidization velocity (Umf), different agitation intensities and different paste feed rates. During the experiments, the influence of agitation on the dimensionless pressure drop, air temperature at the bed outlet, relative air humidity at the bed outlet, powder moisture content, powder production rates and powder accumulation rates were analyzed. Analyzing the obtained results, it may be verified in the two amplitudes that the increase of the agitation intensity, through the increase of the frequency, allowed the use of higher maximum feeds rates of skimmed milk in the equipment. It was also observed, for the values of Γ almost constant with different combinations of A and f, that the agitation with amplitude of 0.015m resulted in the greatest variations of pressure drop during the process, in the lower relative humidity levels, in the higher powder production rate and higher powder accumulation rates at the exit of the cyclone. In this way emphasizing the importance to inform A and f to characterize the implemented vibration in the vibrofuidized bed. From these experimental data was designed a hybrid CST / Neural to describe the heat and mass transfer phenomena that occurred during the drying of skim milk. The results showed that the proposed model presented a great agreement with the experimental data, assuming that the vibrofluidized bed behaved as a perfectly stirred tank.Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)A agitação promovida pelo leito vibrofluidizado possibilita incorporar várias operações unitárias como granulação, revestimento de partículas, secagem de grãos e a secagem de materiais pastosos. No entanto, muito ainda precisa ser estudado sobre a secagem de pasta neste equipamento, pois conforme os trabalhos de Daleffe (2005) e Meili (2009) verificou-se que um mesmo número adimensional de vibração (Γ) apresentou comportamentos fluidodinâmicos diferentes e influenciou de maneiras distintas no processo. Para compreender melhor a interferência dos parâmetros vibracionais neste tipo de operação, o objetivo do presente trabalho consistiu em desenvolver um estudo detalhado sobre a secagem do leite desnatado em leito vibrofluidizado, variando as intensidades de agitação impostas ao leito, duas amplitudes (A), 0,003m e 0,015m, combinadas as frequências (f) que variaram entre 100 e 1100RPM. Desta forma, primeiramente, analisou-se a influência que os parâmetros vibracionais exerceram nas curvas características da queda de pressão e desvio padrão de queda de pressão em função da velocidade superficial do fluido (Us), quando o leito foi constituído com esferas de vidro dos seguintes diâmetros, 0,00119m, 0,00219m e 0,00319m. Em seguida, foram realizados testes de evaporação de água para determinar o tamanho do material inerte e as condições experimentais que seriam usadas nos ensaios de secagem de pasta. Para a secagem do leite desnatado foram usadas as esferas de vidro com 0,00319m de diâmetro médio, temperatura do ar de 100ºC, velocidade superficial do ar 20% superior a velocidade de mínima fluidização (Umf), diferentes intensidades de agitação e diferentes vazões de pastas. Durante estes experimentos analisou-se a influência da agitação nos adimensionais de queda de pressão, temperaturas do ar na saída do leito, umidades relativas do ar na saída do leito, umidades do pó, taxas de produção e taxas de acúmulo do pó. Diante dos resultados obtidos, pode-se verificar nas duas amplitudes que o aumento da intensidade de agitação, através do aumento da frequência, possibilitou o uso de maiores vazões máximas de leite desnatado no equipamento. Também foi observado, para os valores de Γ quase constantes com diferentes combinações de A e f, que a agitação com amplitude de 0,015m resultou nas maiores variações de queda de pressão durante o processo, nos menores patamares de umidade relativa, nas maiores taxa de produção do pó e maiores taxas de acúmulo de pó na saída do ciclone. Salientando assim a importância em informar A e f para caracterizar a vibração implementada no leito vibrofluidizado. A partir destes dados experimentais também construiu-se um modelo híbrido CST/ Rede Neural para descrever os fenômenos de transferência de calor e massa que ocorreram durante a secagem do leite desnatado. Os resultados mostraram que o modelo proposto apresentou boa concordância com os dados experimentais, podendo levar em consideração que o leito vibrofluidizado comportou-se como um tanque perfeitamente agitado
600Incidence, clinical features and management of arrhythmias during ajmaline challenge in patients with suspected Brugada Syndrome
Prefazione
La Matematica può concorrere a formare cittadini responsabili, consapevoli della propria identità civile e culturale e dunque consapevoli dell’importanza di fornire ognuno il proprio contributo per costruire una comunità fondata sul dialogo, la negoziazione, l’interazione. Ciò viene evidenziato sia nelle Indicazioni Nazionali (2007) sia nella Raccomandazione del Parlamento Europeo e del Consiglio relativa alle competenze chiave per l’apprendimento permanente (18/06/2006). Purtroppo questa disciplina viene ancora vista soprattutto nel suo aspetto tecnico, come strumento di calcolo, piuttosto che come potente linguaggio formativo. Si ritiene invece, condividendo quanto già espresso nel Documento di Lisbona nel 2000 e ripreso dal Consiglio di Barcellona nel 2002, che una formazione matematica debba essere posta a fondamento di ogni programmazione educativa e didattica a favore di tutti, compresi gli studenti con disabilità
Comorbidities, Cardiovascular Therapies, and COVID-19 Mortality: A Nationwide, Italian Observational Study (ItaliCO)
Background: Italy has one of the world's oldest populations, and suffered one the highest death tolls from Coronavirus disease 2019 (COVID-19) worldwide. Older people with cardiovascular diseases (CVDs), and in particular hypertension, are at higher risk of hospitalization and death for COVID-19. Whether hypertension medications may increase the risk for death in older COVID 19 inpatients at the highest risk for the disease is currently unknown.Methods: Data from 5,625 COVID-19 inpatients were manually extracted from medical charts from 61 hospitals across Italy. From the initial 5,625 patients, 3,179 were included in the study as they were either discharged or deceased at the time of the data analysis. Primary outcome was inpatient death or recovery. Mixed effects logistic regression models were adjusted for sex, age, and number of comorbidities, with a random effect for site.Results: A large proportion of participating inpatients were >= 65 years old (58%), male (68%), non-smokers (93%) with comorbidities (66%). Each additional comorbidity increased the risk of death by 35% [adjOR = 1.35 (1.2, 1.5) p = 65 years old, indicates that there is a linear direct relationship between the number of comorbidities and the risk of death. Among CVDs, hypertension and pre-existing cardiomyopathy were significantly associated with risk of death. The use of hypertension medications reported to be safe in younger cohorts, do not contribute significantly to increased COVID-19 related deaths in an older population that suffered one of the highest death tolls worldwide
Intermuscular technique for implantation of the subcutaneous implantable defibrillator: a propensity-matched case-control study
Aims A previous randomized study demonstrated that the subcutaneous implantable cardioverter defibrillator (S-ICD) was noninferior to transvenous ICD with respect to device-related complications and inappropriate shocks. However, that was performed prior to the widespread adoption of pulse generator implantation in the intermuscular (IM) space instead of the traditional subcutaneous (SC) pocket. The aim of this analysis was to compare survival from device-related complications and inappropriate shocks between patients who underwent S-ICD implantation with the generator positioned in an IM position in comparison with an SC pocket. Methods and results We analysed 1577 consecutive patients who had undergone S-ICD implantation from 2013 to 2021 and were followed up until December 2021. Subcutaneous patients (n = 290) were propensity matched with patients of the IM group (n = 290), and their outcomes were compared. : During a median follow-up of 28 months, device-related complications were reported in 28 (4.8%) patients and inappropriate shocks were reported in 37 (6.4%) patients. The risk of complication was lower in the matched IM group than in the SC group [hazard ratio 0.41, 95% confidence interval (CI) 0.17-0.99, P = 0.041], as well as the composite of complications and inappropriate shocks (hazard ratio 0.50, 95% CI 0.30-0.86, P = 0.013). The risk of appropriate shocks was similar between groups (hazard ratio 0.90, 95% CI 0.50-1.61, P = 0.721). There was no significant interaction between generator positioning and variables such as gender, age, body mass index, and ejection fraction. Conclusion Our data showed the superiority of the IM S-ICD generator positioning in reducing device-related complications and inappropriate shocks
