Matsumoto Dental University Repository
Not a member yet
    2206 research outputs found

    人歯3次元モデルの作成 : ボクセルモデル

    Get PDF
    application/pdfUsing a 3-dimensional micro-CT (R-mCT, Rigaku), X-rays of 35 human teeth extracted during orthodontic treatment were taken at intervals of 0.125x0.125x0.125mm, and 3-dimensional human tooth models were constructed. The models were visualized using numerical data-visualization software (Micro-AVS ver.8.1, KGT), and display conditions were evaluated, resulting in the following conclusions: 1. Regarding the database of 3-dimensional models, voxel model type data were considered appropriate. 2. Three-dimensional images, which can be used to observe the internal structure, are useful for learning dental students. 3. Simulated treatment becomes possible using the haptick device and 3-dimensional data. This modality was considered very useful clinical practice for students. 4. When data for the finite element method are produced based on these data, various analyses become possible, and researchers can also effectively use these data. 5. If human tooth 3-dimensional data become widely available, various types of usage will be possible; therefore, accumulation of further data on carious, abnormal, and deciduous teeth is necessary to expand the data set.journal articl

    チタンインプラント材の焼鈍温度が機械的性質に及ぼす影響

    Get PDF
    application/pdfインプラントはブラキシズム等によって疲労破壊することが報告されており,この原因は加工歪みによる.したがって加工歪みを取り除くことを目的にチタン(CPTi)を400℃,600℃,800℃,900℃の電気炉(SLC115, Selec)内で,40分,60分,80分間焼鈍した.それぞれ処理した後,引張強さ,伸び,硬さ,疲労破壊,組織観察について検討を行った.その結果,CPTiの引張強さは焼鈍温度が高くなると小さくなる傾向であった.また,引張強さに対する加熱時間の影響は400℃と900℃では認められなく,600℃と800℃では処理時間が長いほど引張強さは小さくなった.伸びは焼鈍温度が高くなると大きくなる傾向であった.また,処理時間に関しては焼鈍温度が低い場合,処理時間が長くなるほど伸びは大きくなった.耐力においては900℃以外は焼鈍温度が高く,処理時間が長いほど小さくなる傾向であった.弾性係数は加熱前よりも大きくなる傾向であり,焼鈍温度,処理時間ともに一定した影響は認められなかった.しかし,900℃に関しては処理時間が長くなるにしたがって弾性係数は大きくなる傾向であった.硬さは,800℃までは焼鈍温度が高いほど小さくなる傾向であり,処理時間による一定した影響は認められなかった.900℃処理では800℃処理よりも硬さが大きくなる傾向であった.疲労破壊は400℃で40分処理が最も良好であった.加熱重量変化においては,加熱することによって重量が増加した.400℃と600℃処理では大差が認められなかったが,900℃処理が最も大きく重量の増加が認められた.その増加量は800℃と比較して4倍であった.組織は800℃と900℃処理では再結晶化が認められ,粗大化していた.疲労破壊面の観察では結晶が微細な400℃と600℃は破断面も微細であり,粗大化した結晶の800℃と900℃では破断面も粗造な状態で観察された.したがって,CPTiを用いインプラント体を加工した場合,加工後400℃で出来るだけ短時間で焼鈍処理を行うことによって疲労破壊を防止することが可能となることが示唆された.journal articl

    第68回松本歯科大学学会(総会)プログラムと講演抄録

    Get PDF
    application/pdfothe

    重複上大静脈と対性の奇静脈および右心室内の異常筋束が同時にみられた一例

    Get PDF
    application/pdfDuring routine dissection by dental students at Matsumoto Dental University 2008, a case of double superior caval vein associated with paired azygos veins was found in a 66-year-old Japanese female cadaver. Both the left and right branchiocephalic veins were formed by the union of the left internal jugular, left vertebrate, and left subclavian veins. Calibers of the left and right superior caval veins were almost the same size, approximately 20mm, respectively. In between the left and right superior caval vein, there was a small anastomosis 3mm in width, running obliquely from the upper left to lower right. The left superior caval vein coursed vertically downward along the aorta and left pulmonary arteries, passed between the left cardiac auricle and the left pulmonary veins to join the coronary sulcus. Both the left and right azygos veins joined the superior caval veins at the level of the 4th thoracic vertebra, receiving superior intercostal veins, respectively. The present case belonged to type D of Nandy and Blair^, and type IIIa of Takenoshita^, respectively. In addition, 4 anastomoses between both the azygos vein in front of the vertebral bodies from the 6th to 9th thoracic vertebrae and aberrant muscle bands in the right ventricle were also found in the present case.journal articl

    重複する下顎後静脈および総顔面静脈が同時にみられた一例

    Get PDF
    application/pdfDuring routine dissection by dental students at Matsumoto Dental University 2008, a case of double superior caval vein and paired azygos veins reported previously also demonstrated duplicate double retromandibular and common facial veins in the left retromandibular fossa of a 66 year old Japanese female cadaver who died of pneumonia. The superficial branch of the left retromandibular vein was formed by a union of the common temporal, anterior auricular and transverse facial veins. The maxillary vein on the same side of the infratemporal fossa was extremely thin. The superficial branch of the retromandibular vein ran posterior to the ramus of the mandible within the superficial substance of the parotid gland. In the area, external jugular artery was not found around the branch, but the facial nerve crossed over its branch. Afterward, the superficial branch was joined by the facial vein inferior to the gland to form the superficial branch of the common facial vein. The superficial branch of the common facial vein drained into the external jugular vein on the superficial layer of the stenocleidomastoid muscle, receiving the posterior auricular vein. The external jugular vein drained into the internal jugular vein at the level of the 6th cervical vertebra. However, the deep branch of the retromandibular vein was deeper than the parotid gland, receiving the tympanic, articular, middle meningeal, and pterygoid plexus. The deep branch ran downward along the external jugular artery. The calibers of the superficial and deep branch of the retromandibular vein were almost equal. The posterior belly of the digastric muscle and stylohyoid and its ligament passed between the superficial and deep branches. The deep branch of the retromandibular vein was joined by the deep facial vein and some branhces to form the deep branch of the common facial vein. The deep branch drained into the internal jugular vein at the level of the 6th cervical vertebra. The present case was not similar to any type that has been proposed previously. The topographical relationships of the duplicate retromandibular vein and facial nerve to the parotid gland in the retromandibular fossa are discussed.journal articl

    第69回松本歯科大学学会(例会)プログラムと講演抄録

    Get PDF
    application/pdfothe

    Institutional Evolutionof the Stalinist Economic System in the 1930's

    Get PDF
    Pdepartmental bulletin pape

    投稿要綱

    Get PDF
    othe

    MR sialographyの有用性

    Get PDF
    application/pdfjournal articl

    インプラント体の構造と強度に関する研究

    Get PDF
    application/pdf歯科用補綴物は大きな咬合力に耐え得る強度が要求され,その材質や形態に様々な検討が加えられて現在に至っているのに対し,インプラント体の強度に関する研究はいまだ十分とは言えず臨床上多くの破折例が報告されている.著者らは,市販チタン製インプラント体の強度について有限要素法による解析を行い,「市販のチタン製インプラント体は,垂直方向の荷重に対しては十分な強度を有しているものの,斜め方向の荷重に対しては弱く,不注意な使用によっては容易に破壊される可能性が存在すること」等を既に報告した.最初に考案されたインプラント体は,全て一体型インプラントであり,強度的には一体型のインプラント体が最も優れている.しかし,このインプラント体は骨との結合が得にくいという問題点があった.この点を解決するためにフィクスチャーとアバットメントに分割された2分割型が開発された.この2分割型はフィクスチャーにアバットメントをネジ込む形態になっているが,アバットメントに加わる回転力によりネジが緩む欠点がある.この欠点を克服するためにアバットメントとネジを分離し,アバットメントが回転しない,またアバットメントの角度が調整できる3分割型が考案され現在の主流となっている.さらにこの3分割型には,インプラント体辺縁骨の吸収や感染を抑える目的から,フィクスチャーを骨辺縁まで挿入し,粘膜下に完全に埋入して骨との結合が計れたのち,粘膜を貫通させる2回法用の形態が開発されている.当然,このような形態の違いはインプラント体の強度に大きな影響を及ぼすと考えられるが,構造と強度の関係を明確に示した報告は無い.そこで,インプラント体の分割数とその強度との関係を明らかにするために,一体型,2分割型,3分割型,4分割型のグレード4純チタンインプラント体について有限要素法を用いて斜め45°方向から荷重した場合の非線形応力解析を行った.その結果,斜め45°方向からの荷重に対しては,分割数が増加するに従い急激に強度が減少し,特に4分割型では咬合力に耐えられないものと考えられた.この解析結果を受けて,3分割型の形態を改良して2回法に適応するインプラント体を設計し解析を行ったところ,実用的な強度を得ることができた.この結果を検証するために,解析と同形態のインプラント体を,JISグレード4チタンを用いて試作し,擬似骨に埋入して荷重試験を行った.その結果,2分割型,3分割型,4分割型はフィクスチャーとアバットメントを固定するネジのネジ切り部で破折したのに対し,一体型と改良3分割型は破折が起こらず,最大荷重,耐力相当荷重ともに解析結果とよく一致していた.しかし荷重試験では,同一構造インプラント体間の荷重一変位曲線にも大きな差が生じていた.試験片を縦断し断面を調べた結果,この差はインプラント体の骨への埋入深さの僅かな違いに起因していることが明らかとなった.上述の結果から,以下の結論に達した.1 インプラント体の強度は分割数の増加に伴い大きく低下するが,JISグレード4チタンであれば3分割までは実用に耐えうる.2 2分割型,3分割型,4分割型のフィクスチャーとアバットメントを固定するネジのネジ切り部最上部には応力が集中する.3 応力集中を避けるようにネジのシャフト部を長く設計した改良3分割型は,荷重試験においても破折が起こらず,有限要素法を用いたインプラント体の設計は極めて有用と考えられた.4 インプラント体は,骨への埋入深さのわずかな違いにより,強度が大きく変化する可能性がある.journal articl

    2,170

    full texts

    2,206

    metadata records
    Updated in last 30 days.
    Matsumoto Dental University Repository
    Access Repository Dashboard
    Do you manage Open Research Online? Become a CORE Member to access insider analytics, issue reports and manage access to outputs from your repository in the CORE Repository Dashboard! 👇