Matsumoto Dental University Repository
Not a member yet
2206 research outputs found
Sort by
Evaluation of Homogeneity on Cone Beam Computed Tomography Imaging with Flat Panel Detector
application/pdfCone beam computed tomography (CBCT) with a flat panel detector can provide more precise and fine images compared to that with an image intensifier which have been used previously. Measurement of the length clearly varies among different measurement regions on the images of CBCT with an image intensifier. However, little is known whether measurement of the length on the images of CBCT with a flat panel detector varies as well or uniform. The objective of this study was, therefore, to analyze the homogeneity of the measurement of the length on the images of the CBCT with a flat panel detector. The results demonstrated that both short- and long-term reproducibility of measurement of the length on the CBCT images of the x-ray mesh gauge was less than 1.5%. The non-uniformity of measurement of the length on the CBCT images was less than 2% between any of two regions. The non-uniformity of measurement of the length on the CBCT images with φ60mm×h60mm exposed area was almost constant at any regions independent of the tube current. That on the CBCT images with φ40mm×h40mm exposed area varied randomly. The non-uniformity of measurement of the length varied randomly on the CBCT images with small exposed area; however, this was considerably small and negligible. The results suggest that measurement of the length on the images of CBCT with a flat panel detector may be substantially uniform at any regions in comparison with that on the images of CBCT with an image intensifier.journal articl
ヒト口唇腺の自律神経線維の免疫組織化学的局在について
application/pdfTo determine the precise distribution of autonomic nerve fibers in human labial glands, tyrosine hydroxylase (TH) was used as a marker of sympathetic nerve fibers and vasoactive intestinal polypeptide (VIP) as a marker of parasympathetic fibers. Then immunohistochemical localizations of nerve fibers stained by TH and VIP were examined in the human labial glands. VIP-immunopositive nerve fibers were detected around the acini and blood vessels. TH-immunopositive nerve fibers were found not only around the blood vessels but also close to the acini, although there was individual variation. In addition, TH-positive nerve fibers were more abundant around the serous acini than around the mucous acini. However, VIP-immunopositive nerve fibers showed almost the same distribution around both the serous and mucous acini. These results about the parasympathetic nerve fibers were in agreement with the results of previous reports. However, unlike the previous papers, sympathetic nerve fibers were found not only around the blood vessels, but also very close around the acini. Most of the TH and VIP-immunopositive nerve fibers were found in proximity to the basement membrane of the acinar cells, but VIP-immunopositive nerve fibers were occasionally found the intercellular space between acinar cells after penetrating the basement membrane. Most of the sympathetic and parasympathetic fibers were the epilemmal type, so that, most acinar cells were separated from nerve fibers by the basement membrane. Both TH and VIP-immunopositive nerve fibers were found among fibers in the nerve bundle coursing through the connective tissue around the human labial gland. Together with the findings of previous studies, this study strongly suggests that sympathetic nerve fibers are distributed in the human labial gland via the trigeminal nerve, along with the distribution of the parasympathetic nerve fibers.journal articl
欠陥を内包したチタン製鋳造クラスプの機械的性質に関する研究
application/pdf【目的】本研究は補綴装置の構成要素の破壊の一因である鋳造欠陥に着目し,特に欠陥がチタン製クラスプに内包されたときの機械的性質について検討する事を目的に,まず,基本的な形態の試験片に実験的な欠陥を加工し,3次元有限要素解析と物証実験を比較し,最終的には欠陥を内包したモデルを製作し機械的性質に及ぼす影響について検討した.【方法】実験1 有限要素解析パラメータの算出と妥当性の検討Commercially Pureチタン(以降,CPチタンと呼ぶ)にはJIS第2種の線材(直径1.0, 2.0mm)と鋳造用インゴットを使用した.まず直径2.0mm線材と鋳造体について引張試験を行い,それぞれの応力-ひずみ曲線から得られた値を解析パラメータとした.さらに,線材と鋳造体について曲げ試験(本実験で行う曲げ試験はすべて片もちはり曲げ試験とした)を行い,実測値と解析値を比較検討し,解析に用いるパラメータの妥当性を確認した.実験2 実験的に欠陥を加工した線材の曲げ試験鋳造欠陥を想定して直径0.3, 0.5, 0.7mmの仮想欠陥を1試料につき1ヶ所切削加工した直径1.0mm線材の曲げ試験を行った.欠陥の位置は固定部から3.0, 6.0, 9.0mm(以降,固定側,中央部,荷重側と呼ぶ)として,機械的性質に与える影響について検討した.実験3 テーパー付き鋳造体における曲げ試験と非線形解析の比較テーパー付き鋳造体に関して,万能試験機による曲げ試験の結果とコンピュータ上で製作したモデルによる解析値を比較した.実験4 欠陥を含有したテーパー付き鋳造体の非線形解析直径0.3, 0.5, 0.7, 1.2mmの球状欠陥を1試料につき1ヶ所含有したテーパー付き鋳造体のモデルについて解析した.また,欠陥の位置は実験1と同様に固定側,中央部,荷重側に設定した.作製したモデルについて曲げによる解析を行い,欠陥の位置と大きさが鋳造体に与える影響について検討した.実験5 欠陥の位置が機械的性質に及ぼす影響これまでの実験で曲げ試験時に最も差が認められた固定側の条件について,鋳造体の位置を中心軸から外側と内側に0.05mmずつ偏位させて解析した.【結果および考察】欠陥が鋳造クラスプの機械的性質に与える影響について有限要素で解析を行ったところ,1.直径1.0mmの鋳造による円柱状試験片では,欠陥の直径が0.3, 0.5mmのとき,機械的性質には影響を及ぼさず,直径が0.7mm以上になると疲労破壊が生じる可能性が示唆された.2.幅2.0mm,厚さ1.7mm(固定部),幅1.6mm,厚さ1.3mm(荷重部)長さ13.0mmのテーパー付き鋳造体では直径1.2mmの欠陥が固定側に存在すると機械的性質は低下し,より小さな応力で変形を起こすことが判明した.3.欠陥が鋳造体の外側に偏位もしくは外側に向かって開放された状態になると機械的性質が大きく低下する傾向が示された.一連の結果より,臨床で欠陥を内包した鋳造体を補綴装置に応用する場合,幅2.0mm,厚さ1.7mm(固定部),幅1.6mm,厚さ1.3mm(荷重部)長さ13.0mmのテーパー付き鋳造体では直径1.2mm以上の欠陥が鉤脚部から鉤肩部に存在すると,欠陥周囲に応力が集中し,破壊する可能性が高くなるので,非破壊検査によってこの様な欠陥が認められた場合,再製作する必要がある事が判明した.journal articl
Basic English Course : Instruction in Three Small Groups(based on questionnaire results)
Pdepartmental bulletin pape
歯科矯正学的メカニカルストレスによりマウス歯根膜組織に発現する熱ショックタンパクの免疫組織化学的観察
application/pdf熱ショックタンパク質(HSPs)は熱ショックのみならず、メカニカルストレスに対しても発現する。歯科矯正治療は、関連する歯周組織にメカニカルストレスを付加する。それを受けた後の歯周組織に発現するHSPの状況を調べる事は極めて重要である。そこで今回、我々は歯科矯正学的メカニカルストレスをWaldo法によってddYマウスの歯根膜組織に与え、その後の変化を病理組織学的ならびに免疫組織化学的に検索した。その結果、対象群ではHSP27と70はともに極めて弱い発現であったのに対し、実験群の牽引側歯根膜組織にHSP27と70の両者の発現増強がみられた。これらの所見は、HSPsは歯根膜組織の恒常性の維持に寄与している事を示唆していた。journal articl