Jurnal Dampak
Not a member yet
    193 research outputs found

    Analisis Sebaran Karbon Monoksida dari Sumber Transportasi dari Jalan Sisingamangaraja dengan Metode Finite Length Line Source Berbasis Sistem Informasi Geografis

    Get PDF
    Purpose of this study is to determine the distribution pattern of carbon monoxide (CO) from Singamangaraja street by using Finite Length Line Source (FLLS) method and map to the distribution with GIS aplication. Based on the results of observations of traffic volume on the Singamangaraja street is 7.591 units/hour (morning) and 7.433 units/hour (noon). The amount emission rate is 49.171.7 ?g/m.s in the morning and 46.943.1 ?g /m.s in the noon. According to calculations FLLS the highest CO concentration is at roadside (20.340 ?g/Nm3 in the morning and 18.340 ?g/Nm3 in the noon). Based on direct measurement of the concentration of a maximum of 18.323 ?g /Nm3 in the morning and 17.177 ?g /Nm3 at noon. Spatial analysis with Geographic Information System generate distribution impact area of the source was Harjosari 2 district. Comparison between modeling and field survey using wilmott’s index method had d=0,69-0,84, R=0,93-0,96, dan NMSE=0,02-0,04. Statistic validation had 16,5%-17% accuracy and still in range of Gaussian criteria (10%- 20%).Keyword: CO, finite length line source, SIG, transportationAbstrak-Penelitian ini bertujuan untuk mengetahui pola sebaran karbon monoksida (CO)dari Jalan Sisingamangarajadengan metode Finite Length Line Source (FLLS) dan memetakan sebaran dengan aplikasi SIG. Berdasarkan hasil pengamatan volume lalu lintas,total jumlah kendaraan adalah 7.591 unit/jam (pagi) dan 7.433 unit/jam (siang). Jumlah kendaraan tersebut menyumbangkan laju emisi sebesar 49.171,7 ?g/m.s pada pagi hari dan pada siang hari sebesar 46.943,1 ?g/m.s. Bedasarkan perhitungan dengan FLLS konsentrasi CO paling tinggi adalah pada tepi jalan (roadside) yaitu sebesar 20.340 ?g/Nm3 pada pagi hari dan 18.340 ?g/Nm3 pada siang hari. Analisa spasial dengan Sistem Informasi Geografis menghasilkan wilayah sebaran dampak dari sumber tersebut adalah Kelurahan Harjosari 2. Perbandingan hasil pemodelan dan hasil pengukuran di lapangan dengan wilmott’s index menghasilkan nilai d=0,69-0,84, R=0,93-0,96, dan NMSE=0,02-0,04. Hasil validasi memiliki keakuratan 16,5%-17%.Kisaran ini masih dalam kriteria pemodelan Gaussian (10%- 20%).Keyword: CO, finite length line source, SIG, transportas

    Analisis Intrusi Air Laut dengan Pengukuran Total Dissolved Solids (TDS) Air Sumur Gali di Kecamatan Padang Utara

    Get PDF
    This research aims to analyze the effect of seawater intrusion with measurement of TDS dug well water in Padang Utara Subdistrict. The measurements of TDS carried out in three villages in Padang Utara Subdistrict, namely the Village are Air Tawar Barat, Ulak Karang Selatan, and Ulak Karang Utara with twice sampling frequency: on November 2015 and February 2016. TDS concentration in November 2015 is in the range of 20 to 9000.8 mg / L, while the measurement of TDS concentration in February 2016 is in the range of 160.8 to 735.2 mg / L. Measurement of TDS in November 2015 showed that there were three wells that indicated to seawater intrusion, i.e. the ULS 8 (1101.6 mg / L), ULS 9 (9000.8 mg / L), and ULU 6 (1926.4 mg / L). Correlation between TDS concentration with coastline distance have a value r amounted to 0,118-.095. The results showed that there are some wells that indicated to seawater intrusion along the coast in Padang Utara Subdistrict.Keywords : distance, dug wells Padang Utara Subdistrict, , seawater intrusion, TDSAbstrak-Penelitian ini bertujuan untuk menganalisis pengaruh intrusi air laut dengan pengukuran TDS pada air sumur gali di Kecamatan Padang Utara. Pengukuran TDS dilakukan di tiga kelurahan di Kecamatan Padang Utara yaitu Kelurahan Air Tawar Barat, Ulak Karang Selatan, dan Ulak Karang Utara dengan frekuensi pengambilan sampel sebanyak dua kali yaitu pada bulan November 2015 dan Februari 2016. Konsentrasi TDS pada November 2015 berada dalam rentang 20-9000,8 mg/L, sedangkan pengukuran konsentrasi TDS pada Februari 2016 berada dalam rentang 160,8-735,2 mg/L. Pengukuran TDS pada ovember 2015 menunjukkan bahwa terdapat tiga sumur yang yang terindikasi mengalami intrusi air laut, yaitu ULS 8 (1101,6 mg/L), ULS 9 (9000,8 mg/L), dan ULU 6 (1926,4 mg/L). Hubungan antara jarak sumur dari bibir pantai terhadap nilai TDS memiliki koefisien korelasi sebesar 0,118 – 0,095, hal ini menunjukkan tidak adanya pengaruh antara jarak dengan nilai TDS. Hasil penelitian menunjukkan bahwa terdapat beberapa sumur yang terindikasi mengalami intrusi air laut di sepanjang pesisir di Kecamatan Padang Utara.Kata kunci : intrusi air laut, jarak, Kecamatan Padang Utara, sumur gali, TD

    Pemanfaatan Titanium Dioxide pada Trotoar untuk Mengurangi Gas Pencemar NOx di Udara

    Get PDF
    The transportation is one of the largest contributor to air pollution in Indonesia, especially in large cities. Fuel gases from combustion in motor vehicles, such as oxides of nitrogen (NOx) will be emitted to the ambient air. Increasing the concentration of NOx in ambient air can be bad for human health, especially with regard to upper respiratory tract disease. Therefore, the development of methods which are environmentally friendly for controlling air pollution remains to be done. One simple way to reduce air pollution is utilizing a cheap process, namely sunlight and effect of catalyst of TiO2, to control the NO and NO2. This method requires no additional energy in addition to ultraviolet rays coming from the Sun. Paving-coated TiO2 ambient air set out in 6 hours, 12 hours, 18 hours and 24 hours. Nitrate and nitrite ions are formed by photocatalytic on the surface of the paving is dissolved with the aquades which is then measured by ion chromatography. The experimental results showed that the composition of TiO2 200  g/m2 of paving is able to adsorp  NOx gas at an average rate of 0.0046 mg/m2/minutes, elevated concentrations of HNO3- along with the duration of exposure. Additional costs for every square meter paving is Rp. 13180.  Keywords: Photocatalytic, nitrate ion, nitric ion, nitrogen oxides (NOx), titanium dioxide (TiO2), pavingABSTRAK Sektor transportasi merupakan salah satu penyumbang pencemaran udara terbesar di Indonesia, terutama di kota-kota besar. Gas-gas hasil pembakaran bahan bakar kendaraan bermotor seperti oksida nitrogen (NOx) akan diemisikan ke udara ambien. Meningkatnya konsentrasi NOx di udara ambien dapat berdampak buruk bagi kesehatan manusia terutama berkaitan dengan penyakit saluran pernafasan bagian atas. Karena itu, pengembangan metode-metode yang ramah lingkungan untuk mengendalikan pencemaran udara harus dilakukan. Salah satu cara sederhana menurunkan pencemaran udara adalah memanfaatkan proses yang murah, yaitu sinar matahari dan efek katalis dari TiO2, untuk mengendalikan NO dan NO2. Metode ini tidak memerlukan energi tambahan selain sinar ultraviolet yang berasal dari matahari. Paving block berlapis TiO2 dipaparkan di udara ambient dalam waktu 6 jam, 12 jam, 18 jam dan 24 jam. Ion nitrat dan nitrit yang terbentuk akibat proses fotokatalitik di permukaan paving dilarutkan dengan aquades yang kemudian diukur dengan ion chromatografi. Hasil percobaan menunjukkan bahwa dengan tambahan TiO2 sebanyak 200 gram untuk setiap meter persegi paving mampu mengadsorpsi gas NOx dengan laju adsorpsi rata-rata sebesar 0,0046 mg/m2/menit, peningkatan konsentrasi HNO3- seiring dengan lamanya proses pemaparan di lapangan. Biaya tambahan untuk setiap meter persegi paving block yaitu Rp. 13180. Kata kunci: fotokatalitik, ion nitrat, ion nitrit, oksida nitrogen (NOx), titanium dioksida (TiO2), paving bloc

    Pengaruh Aerasi Bertingkat dengan Kombinasi Saringan Pasir, Karbon Aktif, dan Zeolit dalam Menyisihkan Parameter Fe dan Mn dari Air Tanah di Pesantren Ar-Raudhatul Hasanah

    Get PDF
    Groundwater if allowed to form a yellow precipitate indicates that contains high levels of Fe and Mn are high, so we need a method that is good in quality and economical way to improve the quality of groundwater. Experimental research that aims to determine the effect of aeration is terraced with a combination of sand, activated carbon and zeolite filter. Examination of the samples is done continuous sampling every 1 hour within 5 hours of the treatment 1 (aeration 2 levels followed by a sand, activated carbon, and zeolite filter), the treatment 2 (aeration 2 levels with a combination of zeolite followed by a sand, activated carbon, and zeolite filter), and the treatment 3 (sand, activated carbon, and zeolite filter). The best decreased levels of Fe is to use the treatment 1 with an efficiency decrease of 47,22 %. Whereas decreased levels of Mn best is on each treatment with the efficiency of a decrease of 100 %. Statistical analysis showed that there are differences in the levels of Fe in the tool 1, tool 2 and the tool 3 p (0.028 < 0.05). There is no difference in the levels of Mn on treatment 1, treatment 2, and treatment 3 p (0146 > 0.05).Keywords : Groundwater, Fe, Mn, Multilevel aeration, Sand activated carbon zeolite filterAbstrakAir tanah yang jika dibiarkan membentuk endapan kuning menunjukkan bahwa masih mengandung kadar Fe dan Mn yang tinggi, sehingga diperlukan suatu metode yang baik dalam kualitas dan ekonomis untuk meningkatkan kualitas air tanah. Penelitian yang bersifat eksperimen ini bertujuan untuk mengetahui pengaruh aerasi bertingkat dengan kombinasi saringan pasir, karbon aktif dan zeolit. Pemeriksaan sampel dilakukan secara continuous sampling setiap 1 jam sekali dalam 5 jam pada alat 1 (aerasi 2 tingkat dilanjutkan dengan saringan pasir, karbon aktif, dan zeolit), alat 2 (aerasi 2 tingkat dengan kombinasi zeolit dilanjutkan dengan saringan pasir, karbon aktif, dan zeolit), dan alat 3 (saringan pasir, karbon aktif, dan zeolit). Penurunan kadar Fe yang tertinggi ialah menggunakan alat 1 dengan efisiensi penurunan sebesar 47,22 %. Sedangkan penurunan kadar Mn yang terdapat pada setiap alat dengan efisiensi penurunan sebesar 100 %. Hasil uji statistik menunjukkan bahwa ada perbedaan konsentrasi Fe pada alat 1, alat 2 dan alat 3 p (0.028 < 0.05). Tidak ada perbedaan konsentrasi Mn pada alat 1, alat 2 dan alat 3 p (0.146 > 0.05). Kata Kunci: Aerasi Bertingkat, Air Tanah, Fe, Mn, Saringan Pasir Karbon Aktif Zeoli

    Pengaruh Penambahan Serpihan Kayu terhadap Kualitas Kompos Sampah Organik Sejenis dalam Komposter Rumah Tangga

    Get PDF
    One way to improve compost quality of typical organic waste is by addition of additive such as wood chips. This study aims to analyze the impact of the wood chips addition (ratio 1:10) on compost quality of typical organic waste (fruits, vegetables, yard waste, and food waste) in home composter, and to compare the compost quality with the standard of domestic compost according SNI 19-7030-2004. Analysis was conducted on compost’s raw material, compost maturity process in every 5 days measurement, and on compost product. Analysis of compost product of typical organic waste with addition of wood chips showed that parameters of temperature, moisture content, and pH of vegetables and yard waste has complied the standard whilst parameter of C/N ratio has not complied. The addition of wood chips caused the drop of compost temperature and moisture content, resulted in the decomposition process located in aerobic condition, resulted in production of compost in form of humus in greater volume. The addition of wood chips also caused the compost pH and C/N ratio increased.Keywords: compost quality, home composter, typical organic waste, wood chipsAbstrakSalah satu upaya untuk memperbaiki kualitas kompos sampah organik adalah dengan penambahan bahan aditif, seperti serpihan kayu. Penelitian ini bertujuan untuk menganalisis pengaruh penambahan serpihan kayu (perbandingan 1:10) terhadap kualitas kompos sampah organik sejenis (buahan, sayuran, halaman dan sisa makanan) dalam komposter rumah tangga dan membandingkan kualitas akhir kompos ini dengan kualitas kompos sampah domestik menurut SNI 19-7030-2004. Analisis dilakukan terhadap bahan dasar kompos, proses kematangan dengan pengukuran setiap lima hari sekali, dan kualitas akhir kompos. Dari analisis akhir kualitas kompos sampah organik sejenis dengan penambahan serpihan kayu, parameter yang telah memenuhi standar adalah temperatur, kelembapan, pH untuk sampah sayuran dan sampah halaman, sedangkan untuk parameter rasio C/N belum memenuhi standar. Penambahan serpihan kayu menyebabkan temperatur dan kelembaban kompos menurun, sehingga proses dekomposisi berada pada suasana aerobik, yang menghasilkan kompos dalam bentuk humus dengan volume yang lebih banyak. Penambahan serpihan kayu juga meningkatkan pH dan rasio C/N kompos. Kata kunci: komposter rumah tangga, kualitas kompos, sampah organik sejenis, serpihan kay

    Pengaruh Komposisi Bahan Baku Kompos (Sampah Organik Pasar, Ampas Tahu, dan Rumen Sapi) terhadap Kualitas dan Kuantitas Kompos

    Get PDF
    This research combines market waste (SP), Soybeanwaste and the cow's rumen (RS) as raw material for composting. Composter consists of eight variations, variations 1 (60% SP; 40% AT; 0% RS), variation of 2 (60% SP; 20% AT; 20% RS), variation 3 (50% SP; 30% AT; 20 % RS), variations in 4 (40% SP; 40% AT; 20% RS), variations in 5 (70% SP; 10% AT; 20% S), variations in 6 (60% SP; 30% AT; 10% RS ), variations in 7 (50% SP; 40% AT; 10% RS), variations of 8 (60% SP; 20% AT; 20% RS; EM4). This study aimed to analyze the effect of variations composition of the compost raw materials in order to obtain a variation of the most optimum for composting. The methods used are composting semiaerob. The observation of the maturity of the compost to the parameters of temperature, pH and color meets the standards of SNI 19-7030-2004 with composting 16-33 days old. The results of the analysis of all variations of the water content of the compost quality, C-organic, nitrogen, C / N ratio, phosfor, and potassium, has met the standard of SNI 19-7030-2004. Of the total raw material compost as much as 3 liters, obtained quantity of solid compost and liquid compost from 0.45 to 0.87 liters of 0.45 to 1.2 liters. Based on the scoring result of the maturity, quality, and quantity of compost, obtained the best variation is a variation 5.Keywords : Soybean waste,kompos quality and quantity, cow's rumen, market waste Abstrak-Penelitian ini mengkombinasikan sampah pasar (SP), ampas tahu (AT) dan rumen sapi (RS) sebagai bahan baku pengomposan. Tujuan penelitian untuk menganalisis pengaruh variasi komposisi bahan baku kompos sehingga diperoleh variasi yang optimum untuk proses pengomposan. Komposter terdiri dari 8 variasi yaitu variasi 1(60% SP; 40% AT; 0% RS), variasi 2 (60% SP; 20% AT; 20% RS), variasi 3 (50% SP; 30% AT; 20% RS), variasi 4 (40% SP; 40% AT; 20% RS), variasi 5 (70% SP; 10% AT; 20% S), variasi 6 (60% SP; 30% AT; 10% RS), variasi 7(50% SP; 40% AT; 10% RS), variasi 8 (60% SP; 20% AT; 20% RS; EM4). Metoda yang digunakan adalah pengomposan semiaerob. Hasil pengamatan terhadap kematangan kompos untuk parameter temperatur, pH, warna telah memenuhi standar SNI 19-7030-2004 dengan lama pengomposan 16-33 hari. Hasil analisis semua variasi kualitas kompos yaitu kadar air, C-organik, nitrogen, rasio C/N, phosfor, dan kalium, telah memenuhi standar SNI 19-7030-2004. Dari total bahan baku kompos sebanyak 3 liter, didapatkan kuantitas hasil kompos padat 0,45-0,87 liter dan kompos cair 0,45-1,2 liter. Berdasarkan hasil skoring terhadap kematangan, kualitas, dan kuantitas kompos, didapatkan variasi terbaik adalah variasi 5 (70% SP; 10% AT; 20% RS).Kata Kunci : Ampas tahu, kualitas kompos, kuantitas kompos, rumen sapi, sampah pasa

    Kajian Penerapan Sistem Pengelolaan Sampah dengan Pendekatan Metode 3R di Kabupaten Padang Pariaman

    Get PDF
     This study aims to determine the existing conditions of solid waste management in Padang Pariaman Regency and the problems faced, as well as to assess the potential of implementing a municipal solid waste management system using the reduce-reuse-recycle (3R) method through a 3R based Solid Waste Treatment Plant (3R-SWTP) for region scale and Integrated Solid Waste Treatment Plant (ISWTP) for the city scale as a solution to municipal solid waste problems. This study was conducted through surveys, observations and interviews with solid waste management institutions, collection of secondary solid waste management data and literature studies. From the survey, observation, and interview it was found that the solid waste generation of Padang Pariaman Regency was 1,396 m3/day and only 1,35% of the total solid waste was served. The problem of waste management faced were  the high amount of waste that is not served, the inadequate facilities and infrastructure for operational solid waste handling and the low level of solid waste minimization practices. Through the implementation of the 3R-SWTP and ISWTP-based solid waste management system, it is estimated that it will be able to minimize the city solid waste by 23% by operation of 7 unit of 3R-SWTP and 1 unit of ISWTP within 5 years. Keywords: solid waste management system, 3R method, 3R-SWTS, ISWTP, Padang Pariaman Regency  ABSTRAK  Penelitian ini bertujuan untuk mengetahui kondisi eksisting pengelolaan sampah di Kabupaten Padang Pariamandan permasalahan yang dihadapi, serta mengkaji potensi penerapan sistem pengelolaan sampah kota dengan pendekatan metode reduce-reuse-recycle (3R) melalui sistem pengelolaan sampah berbasis Tempat Pengolahan Sampah (TPS3R)untuk skala kawasan dan Tempat Pengolahan Sampah Terpadu (TPST) untuk skala kota sebagai solusi permasalahan sampah kota kedepan. Studi ini dilakukan melalui survey, observasi dan wawancara dengan lembaga pengelola sampah, pengumpulan data skunder pengelolaan sampah dan studi literatur. Dari survey, observasi, dan wawancara diketahui bahwa timbulan sampah Kabupaten Padang Pariaman sebesar 1.396 m3/hari dan hanya1,35% sampah yang terlayani.Permasalahan pengelolaan sampah yang dihadapi adalah besarnya timbulan sampah yang tidak terlayani, sarana dan prasarana teknis operasional penanganan sampah yang belum memadai serta rendahnya praktik minimisasi sampah. Melalui penerapan sistem pengelolaan sampah berbasis TPS3R dan TPST diperkirakan akan dapat meminimisasisampah kota sebesar23% dengan operasional 7 buah TPS3R dan 1 buah TPST dalam jangka waktu 5 tahun. Kata Kunci: Sistem pengelolaan sampah, metode 3R, TPS3R, TPST, Kabupaten Padang Pariaman        Â

    ANALISIS SISTEM PENGELOLAAN SAMPAH PERKANTORAN KOTA PADANG MENGGUNAKAN METODE LIFE CYCLE ASSESSMENT

    Get PDF
    Life Cycle Assessment (LCA)is a method to assess and to evaluate total environmental impact of a product, process or service. Simplified LCA has applied to solid waste management of institutional source of Padang City which applies two types of systems included Mixed Management System and Separated Management System. Study based on solid waste management of Major Office of Padang City which generated waste as 5.1194 m3 per week. Life cycle of mixed management system consist of generation, storage, collection, transportation to landfill, treatment on landfill, transportation to informal recycler, and treatment of informal recycler. Separated management system consist of generation, storage, collection, transportation to informal recycler, treatment on informal recycler, transportation to landfill, and treatment on landfill. Total material generated was 6.6320 m3 /weekon mixed system and 4.1815 m3/ weekon separated system. Energy needed for mixed system was 0.0164 m3/ weekand 0.0102 m3/ weekon separated system. The highest environmental impact for both systems were on ecosystem quality damage for treatment on landfill phase as  13.1519 weighting unit of mixed system and 7.7743 weighting unit for treatment on landfill for separated system. Comparative analysis of both systems on equal quantity of waste reveals that separated system is more environmentally friendly than mixed system. Keywords: Simplified LCA, solid waste management system of institutional source, mixed system, separated system, environmental impactpengolahan di lapak (lapak besar dan bandar), sedangkan untuk sistem terpisah terdiri dari tahap timbulan, tahap pewadahan, tahap pengumpulan, tahap pengangkutan ke lapak, tahap pengolahan di lapak (lapak kecil, lapak besar, dan Bandar), tahap pengangkutan ke TPA, dan tahap pengolahan di TPA. Total buangan material sebesar 6,6320 m3/mingguuntuk sistem tercampur dan 4,1815 m3/mingguuntuk sistem terpisah, volume energi yang dibutuhkan sistem tercampur yaitu 0,0164 m3/minggudan 0,0102 m3/mingguuntuk sistem terpisah. Dampak lingkungan terbesar yang mungkin terjadi adalah potensi gangguan keseimbangan ekologi, yaitu sebesar 13,1519 satuan bobot untuk pengolahan di TPA sistem tercampur dan 7,7743 satuan bobot untuk pengolahan di TPA sistem terpisah. Berdasarkan hasil analisis yang diperoleh, untuk sampah dengan kuantitas yang sama, sistem terpisah lebih ramah lingkungan dibandingkan sistem tercampur. Kata-kata kunci:  LCA sederhana, sistem pengelolaan sampah perkantoran, sistem tercampur, sistem     terpisah, dampak lingkunga

    PERANCANGAN SISTEM PLAMBING AIR BERSIH GEDUNG FAVE HOTEL PADANG

    Get PDF
    Fave Hotel Padang is a residential occupancy which has six floors. According to Indonesian National Standard (SNI) No.03-7065-200, the building which has more than 500 inhabitants or more than 1.500 visitors, should prepare plumbing system design. In this paper, plumbing water supply and fire protection system were designed. The water is supplied by deep well of 19,012 m3/hour. The water supply system  used roof tank system with combination of down feed and booster system. Water sorage used ground- and roof tank, with the capacity 136 m3 and 15 m3respectively. Booster pump fulfilled the critical head at 3rd floor up to 6th floor. The hot water supply used central instalation by down feed combined with booster pump. The fire protection system according to the fire hazzard category II used hydrant and sprinkler system by wet-automatic standpipe.  The distribution pipe for clean water is PVC type (1/2 – 4) inch, for hot water is Black Steel (3/4 – 1) inch and for hydrant and sprinkler is Black Steel (1 – 6) inch. Keyword: Indonesian National Standard No. 03-7065-2005, Fave Hotel Building, down feed and booster systems, hot water circulation system, hydrants and sprinkler systems ABSTRAK Fave Hotel Padang merupakan gedung yang termasuk hunian kumpulan yang terdiri dari enam lantai. Berdasarkan SNI 03-7065-2005, gedung yang mempunyai jumlah penghuni lebih dari 500 orang atau jumlah pengunjung lebih dari 1.500 orang harus mempunyai perancangan sistem plambing. Dalam makalah ini akan direncanakan sistem plambing air bersih dan pencegah kebakaran Fave Hotel. Sumber air bersih disuplai dari sumur bor sebesar 19,012 m3/jam.  Sistem penyediaan air bersih menggunakan sistem tangki atap dengan kombinasi aliran gravitasi dan pompa booster. Tangki penyediaan air bersih yang digunakan adalah tangki bawah dan tangki atas dengan kapasitas masing-masing 136 m3 dan 15 m3.Pompa booster memenuhi tekanan kritis pada lantai 3 sampai dengan lantai 6 dengan head  10,26 m. Sistem penyediaan air panas menggunakan sistem instalsi sentral dengan aliran ke bawah dikombinasikan dengan pompa booster. Sistem pencegahan kebakaran kategori kelas II menggunakan sistem hidran dan sprinkler dengan pipa tegak tipe basah-otomatik. Pipa distribusi air bersih yang digunakan pipa PVC (1/2 – 4) inci, pipa distribusi air panas Black Steel (3/4 – 1) inci dan pipa hidran dan sprinkler Black Steel (1 – 6) inci. Kata Kunci :         SNI 03-7065-2005, Gedung Fave Hotel, Sistem gravitasi dan booster, sistem sirkulasi air panas, sistem hidran dan sprinkler

    Analisis Tingkat Kebisingan di Kawasan Kampus Universitas Putra Indonesia (UPI) di Kecamatan Lubuk Begalung Kota Padang

    Get PDF
    The purpose of this research is to analyze the data measuring the noise level in the campus of the University of Putra Indonesia (UPI). Measurement point exterior and interior consists of 12 points and 7 points. The measurement method is based on Decree of the Indonesia Minister of Environment No. 48 of 1996 on Baku Noise is a method simple way by using Sound Level Meter. The highest level of exterior noise when L1 at the point of the Campus Gate UPI (1A) of 73.72 dB (A). The noise level in the afternoon (LS) between 69.63 to 61.60 dB (A), the noise level night (LM) between 48.10 to 38.72 dB (A) and the day-night noise level (LSM) between 67.91 to 59.93 dB (A). The highest current interior noise levels of activity in Building D (2B) of 69.96 dB (A), while the highest level of interior noise occurs at the point when empty Building G (7B) of 69.37 dB (A). Value exterior noise when the time L1-L4 exceeds Raw Noise Level while the value of interior noise when the condition activity partly exceeded Raw Noise except Building G (7B) and the value of noise when empty condition partly exceeds the noise level except Building UPI Sport & Exhibition Hall (1B), Building B (3B) and Building A (4B). Control recommendations exterior form of vegetation while the interior of the control building construction improvements. Keywords: noise, University of Putra Indonesia (UPI) campus, exterior, interior, control alternative recommendation ABSTRAK Tujuan penelitian adalah menganalisis data pengukuran tingkat kebisingan di kawasan Kampus Universitas Putra Indonesia (UPI). Titik pengukuran eksterior dan interior terdiri atas 12 titik dan 7 titik. Metode pengukuran berdasarkan KepMen LH No. 48 Tahun 1996 tentang Baku Tingkat Kebisingan yaitu metode cara sederhana dengan menggunakan alat Sound Level Meter. Tingkat kebisingan tertinggi eksterior pada saat L1 di titik Pintu Gerbang Kampus UPI (1A) sebesar 73,72 dB(A). Tingkat kebisingan pada siang (LS) antara 69,63-61,60 dB(A), tingkat kebisingan malam (LM) antara 48,10-38,72 dB(A) dan tingkat kebisingan siang-malam (LSM) antara 67,91-59,93 dB(A). Tingkat kebisingan interior tertinggi saat aktivitas di Gedung D (2B) sebesar 69,96 dB(A) sedangkan tingkat kebisingan interior tertinggi saat kosong terjadi di titik Gedung G (7B) sebesar 69,37 dB(A). Nilai kebisingan eksterior saat waktu L1-L4 melebihi Baku Tingkat Kebisingan sedangkan nilai kebisingan interior saat kondisi aktivitas sebagian melebihi Baku Tingkat Kebisingan kecuali Gedung G (7B) dan nilai kebisingan saat kondisi kosong sebagian melebihi baku tingkat kebisingan kecuali Gedung UPI Sport & Exhibition Hall (1B), Gedung B (3B) dan Gedung A (4B). Rekomendasi pengendalian eksterior berupa penanaman vegetasi sedangkan pengendalian interior berupa perbaikan konstruksi bangunan. Kata kunci: kebisingan, kampus Universitas Putra Indonesia (UPI), eksterior, interior, rekomendasi alternatif pengendalian 

    185

    full texts

    193

    metadata records
    Updated in last 30 days.
    Jurnal Dampak
    Access Repository Dashboard
    Do you manage Open Research Online? Become a CORE Member to access insider analytics, issue reports and manage access to outputs from your repository in the CORE Repository Dashboard! 👇