İstanbul Sağlık ve Teknoloji Üniversitesi Kurumsal Akademik Arşivi
Not a member yet
    1249 research outputs found

    Vasküler travmada kompartman sendromu

    No full text
    Kalp ve damar cerrahları olarak, kompartman sendromunu (KS) en sık ekstremiteler de tecrübe etmekteyiz. Kompartman sendromunu, fasya ile sarılı olan kas gruplarının bulunduğu bir alanda basıncın artması ile gelişen perfüzyon bozukluğu olarak tanımla yabiliriz (1,2).KS tanısı koymak ve ardından tedavilerine başlamak hayatidir. Erken tanı ve uygun müdahale ile kompartman sendromunun komplikasyonlarından (rabdomyoliz, hiperkalemi, akut böbrek hasarı…) kaçınılabilir

    Pumpkin seeds and their effects on prostate health

    No full text
    The prostate, an essential male reproductive gland, produces and secretes components of seminal fluid and plays a crucial role in male reproductive health. Benign prostatic hyperplasia (BPH) is an age-associated condition marked by non-cancerous enlargement of this gland, increasingly prevalent among older men. More than 40% of men aged 50–60 and over 70% of those aged 61–70 are affected, with incidence reaching up to 90% by the ninth decade (1-8). Histologically, BPH involves the proliferation of epithelial and smooth muscle cells in the prostatic transition zone, leading to bladder outlet obstruction and associated lower urinary tract symptoms (LUTS), such as urgency, nocturia, and a weakened urine stream (9, 10). Although not life-threatening, BPH significantly impacts the quality of life and can lead to complications like urinary retention and renal issues (11). The condition’s high prevalence and its substantial impact on men’s health have made it a significant focus of medical research and therapeutic development

    Kil/LLDPE ve organik kil/LLDPE nanokompozitelerinin mekanik özellikleri

    No full text
    Linear low-density polyethylene (LLDPE) is widely used in many areas in daily life because it is both light and flexible. In this study, clay/LLDPE and organoclay/LLDPE nanocomposites were obtained by melt intercalation method, incorporating small amounts (1- 5 wt.%) of nanosized clay and organoclay modified with a positively charged salt to enhance the mechanical properties of the polymer. Characterization and mechanical tests showed that the mechanical strength of the composites increased with additive content, though some flexibility was partially lost. FTIR and XRD analyses confirmed that clay and organoclay interacted with polymer chains and dispersed homogeneously. ANOVA results demonstrated that both filler type and concentration significantly influence the mechanical properties, with organophilic organoclay showing superior interaction to the LLDPE matrix compared to hydrophilic clay. Specifically, the addition of 5 wt.% organoclay resulted in increases of 56,67%, 58,73%, and 39,53% in elastic modulus, yield strength, and tensile strength, respectively. Additionally, the observed 5% rise in melting temperature suggests potential for expanding the application range of these nanocomposites to areas requiring thermal stability.Lineer düşük yoğunluklu polietilen (LLDPE), hem hafif hem de esnek olması nedeniyle günlük yaşamda birçok alanda yaygın olarak kullanılmaktadır. Bu çalışmada, polimerin mekanik özelliklerini iyileştirmek amacıyla pozitif yüklü tuz ile modifiye edilmiş organokil ve nano boyutlu kilin düşük miktarlarının (ağ. %1-5) kullanıldığı eriyik interkalasyon yöntemi ile kil/LLDPE ve organokil/LLDPE nanokompozitleri elde edilmiştir. Karakterizasyon ve mekanik testler, katkı miktarının artışıyla kompozitlerin mekanik dayanımının arttığını ancak esnekliklerinin kısmen azaldığını göstermiştir. FTIR ve XRD analizleri, kil ve organokilin polimer zincirleriyle etkileşime girerek homojen bir şekilde dağıldığını doğrulamıştır. ANOVA sonuçları, dolgu tipi ve konsantrasyonunun mekanik özellikler üzerinde önemli bir etkiye sahip olduğunu ve organofilik organokilin, hidrofilik kile kıyasla LLDPE matrisi ile daha üstün bir etkileşme gösterdiğini ortaya koymuştur. Özellikle, %5 ağırlık oranında organokil ilavesi ile elastik modülde %56,67, akma dayanımında %58,73 ve çekme dayanımında %39,53 oranında artış gözlenmiştir. Ayrıca, erime sıcaklığındaki %5’lik artış, bu nanokompozitlerin sıcaklık değişimlerine karşı dayanıklılık gerektiren uygulama alanlarında kullanım potansiyelini artırabileceğini göstermektedir

    Apoptosis-inducing, anti-angiogenic and anti-migratory effects of a dinuclear Pd(II) complex on breast cancer: A promising novel compound

    No full text
    Because of the high mortality and morbidity rate of breast cancer, successful management of the disease requires synthesis of novel compounds. To this end, ongoing attempts to create new candidates include synthesis of multinuclear metal complexes. The high DNA binding affinity and cytotoxic activity of these complexes makes them promising as breast cancer treatments. This study investigated anti-growth/cytotoxic effect of the dinuclear Pd(II) complex on breast cancer cell lines (MCF-7, MDA-MB-231) using various methods of staining, flow cytometry, and immunoblotting. The study conducted colony formation, invasion, and migration assays were to assess the effect of the complex on metastasis. Increased caspase-3/7 levels and positive annexin V staining were observed in both cell lines, proving apoptosis. Altered TNFR1 and TRADD expression with caspase-8 cleavage followed by BCL-2 inactivation with loss of mitochondrial membrane potential confirmed the presence of apoptosis in MCF-7 and MDA-MB-231, regardless of p53 expression status. The results implied anti-migration properties. Finally, the study used the CAM assay to assess antiangiogenic properties and showed that the complex inhibited angiogenesis. The study concluded the dinuclear Pd(II) complex warrants further in vivo experiments to show its potential in the treatment of breast cancer.Istanbul University -- 3167

    Formulation of neoprene/chloroprene rubber, examination of their physical, mechanical and rheological properties

    No full text
    Bu çalışmada geliştirilen aleve dayanıklı neopren/kloropren konveyör bant formülasyonunun fiziksel, mekanik ve reolojik özellikleri incelenmiştir. Öncelikle reolojik özelliklerden vulkanizayon eğrisi reometre ile elde edilmiş, vulkanize olan kompozitler fiziksel ve mekanik testler için hazır hale getirilmiştir. Belirlenen standartlara göre alınan konveyör bant numunelerine yoğunluk, sertlik, kopma uzaması ve çekme mukavemeti ve aşındırma testleri yapılmıştır. Test sonuçlarına göre, çekme dayanımı; 219,9 N/mm2, kopma noktasındaki yük; 290,33 N, kopma noktasındaki uzama yüzdesi; %520,37, sertlik; 59,740,90, aşınma; 78,562,49 mm3 ve yoğunluk; 1,1080,051 g/cm3’tür. Yapılan testler Türk Standartları Enstitüsünün yer altı madenlerinde kullanılabilecek tekstil karkaslı kauçuk veya plastik kaplı konveyör bantlar için sunduğu standartlara uyumlu olarak bulunmuştur.In this study, physical, mechanical and rheological properties of flame resistant neoprene/chloroprene conveyor belt formulation were investigated. Firstly, vulcanization curve was obtained by rheometer and the vulcanized composites were prepared for physical and mechanical tests. Density, hardness, elongation at break, tensile strength and abrasive abrasion tests were performed on conveyor belt samples taken according to the specified standards. According to the test results, tensile strength; 219,9 N/mm2, load at break; 290,33 N, elongation at break; 520,37 %, hardness; 59,740,90, abrasion; 78,562,49 mm3 and density; 1,1080,051 g/cm3. The tests were found to be in compliance with the standards of the Turkish Standards Institute for rubber or plastic-coated conveyor belts with textile carcasses that can be used in underground mines

    Comparison of eating awareness of the average obese rates who have had bariatric surgery and those who have not had bariatric surgery

    No full text
    Bu araştırmada 200 kişiye yeme farkındalığı ölçeği (YFÖ-30) ve sosyodemografik anket uygulanmış olup bu 200 kişinin 100’ünü obez bireyler, 100’ünü bariatrik cerrahi geçirmiş bireyler olmak üzere iki grup oluşturmuştur. Elde edilen veriler SPSS ve Excell kapsamında değerlendirilmiş ve yorumlanmıştır. Yapılan bu araştırmada 9 "Bariatrik cerrahi geçirmiş bireyler ve geçirmemiş obez bireylerin yeme farkındalıklarının karşılaştırılması" konusu incelenmiş olup konu hakkında detaylı bir literatür taraması yapılmıştır. Bariatrik cerrahi kavramı, obezite kavramı ve bu iki terimin birbiri ile ilişkisi ele alınmıştır. Sonrasında ortaya çıkan veriler ve literatür taraması birleştirilerek tez çalışması oluşturulmuştur. Obezite, vücut kitle indeksinin (VKİ) 30 kg/m2 veya üzerinde olması durumudur. Obezite, kalp hastalığı, diyabet, hipertansiyon, uyku apnesi gibi pek çok sağlık sorununa yol açabilir. Vücutta aşırı yağ birikmesi sonucu oluşmaktadır. Vücut kitle indeksi (VKİ) adı verilen bir ölçü ile belirlenmektedir. VKİ, boy ve kilo oranına göre hesaplanmaktadır. VKİ’si 25’in üzerinde olanlar fazla kilolu, 30’un üzerinde olanlar ise obez olarak kabul edilmektedir. Bariatrik cerrahi, obezite tedavisinde kullanılan ve günümüzde oldukça popüler olan bir cerrahi yöntemidir. Baritarik cerrahi ameliyatı olabilmesi için obez bireylerin vücut kitle indeksinin 40 üzeri olması gerekmektedir. Bariatrik cerrahi, midenin veya bağırsağın boyutunu veya işlevini değiştirerek kilo kaybına yardımcı olmaktadır. Yapılan bu çalışma hem konunun öneminin ortaya koyulması hem de yapılacak diğer çalışmalara ışık tutması açısından büyük bir önem taşımaktadır. Uygulanan yeme farkındalığı ölçeğinin skorları değerlendirilmiş olup, istatistiksel verileri karşılaştırılmıştır. Düşünmeden yeme, duygusal yeme, yeme kontrolü, yeme disiplini, bilinçli beslenme ve enterferans boyutu bakımından bariatrik grup ortalaması obez grup ortalamasından istatistiksel olarak anlamlı yüksek bulunmuştur (p<0,001). Ama farkındalık boyutu bakımından bariatrik grup ortalaması (2,87±0,32) ile obez grup ortalaması (2,73±0,66) arasında istatistiksel olarak anlamlı fark bulunamamıştır (p=0,071).In this research, the eating awareness scale (YFA-30) and sociodemographic survey were applied to 200 people, and two groups were formed: 100 of these 200 people were obese individuals and 100 were individuals who had bariatric surgery. The data obtained was evaluated and interpreted within the scope of SPSS and Excel. In this research, the subject "Comparison of eating awareness of individuals who have undergone bariatric surgery and obese individuals who have not" was examined and a detailed literature review was conducted on the subject. The concept of bariatric surgery, the concept of obesity and the relationship between these two terms are discussed. Afterwards, the thesis study was created by combining the resulting data and literature review. Obesity is a body mass index (BMI) of 30 kg/m2 or above. Obesity can lead to many health problems such as heart disease, diabetes, hypertension and sleep apnea. It occurs as a result of excessive fat accumulation in the body. It is determined by a measure called body mass index (BMI). BMI is calculated based on height and weight ratio. Those with a BMI over 25 are considered overweight, and those with a BMI over 30 are considered obese. Bariatric surgery is a surgical method used in the treatment of obesity and is very popular today. In order to undergo bariatric surgery, the body mass index (BMI) of obese individuals must be < 40. Bariatric surgery helps with weight loss by changing the size or function of the stomach or intestine. This study is of great importance in terms of both revealing the importance of the subject and shedding light on other studies to be carried out. The scores of the applied eating awareness scale were evaluated and the statistical data were compared. The bariatric group average was found to be statistically significantly higher than the obese group average in terms of impulsive eating, emotional eating, eating control, eating discipline, conscious nutrition and interference dimension (p<0.001). However, in terms of awareness dimension, no statistically significant difference was found between the bariatric group average (2.87±0.32) and the obese group average (2.73±0.66) (p=0.071)

    Traces of sustainability on bottled mineral water packaging: Türkiye vs. Sweden

    No full text
    Globally, the bottled water market is one of the most enormous volume cat egories in the beverage industry. Massively using these packaged beverages is a concern for environmental sustainability due to the production process and plastic waste (1). In this context, mineral waters that support sustainable health are especially expected to be environmentally friendly. In the Euro pean Union (EU) member states, the legal regulations regarding sustainable environment attract attention (2). However, the literature could be more comprehensive in comparing EU and non-EU member states. This study aims to compare the bottled mineral water market in Türkiye and Sweden regarding sustainability-related traces in labels and packaging. For this pur pose, the largest supermarket chains were visited in İstanbul, Türkiye (n=5), and Umeå, Sweden (n=3). Bottled mineral waters were determined (n=21 in Türkiye, n=18 in Sweden), and the environmental sustainability-related label information was recorded from the bottles supplied by the manufacturers. The data were analyzed with descriptive statistics via Jamovi software (ver sion 2.6.2). The distributions of sustainability regarding logos, information, and package design in total products (n=39) were PET-1 (10.3% in Türkiye; 17.9% in Sweden), GL-71 (43.6% in Türkiye), recyclable packaging (51.3% in Türkiye; 46.2% in Sweden), green dot (48.7% in Türkiye), deposit mark (46.2% in Sweden), and tethered caps (17.9% in Türkiye; 43.6% in Sweden). Addition ally, while a Turkish brand’s products were vegan, a brand’s drinks in Sweden were produced with renewable energy. This study was only label-based and assessed the mineral waters market in Türkiye and Sweden. A comparison of the assessed sustainable indications revealed several variations. The wide spread use of tethered caps and deposit payments in Sweden encourages consumers to recycle plastic garbage and prevent environmental pollution with a planned recycling system. For a sustainable future, similar practices must also be expanded in Türkiye

    Ortognatik cerrahi operasyonu sırasında ve sonrasında gelişen komplikasyonların değerlendirilmesi

    No full text
    Objective: The aim of this study was to evaluate the incidence of preoperative and postoperative complications in patients undergoing orthognathic surgery. Methods: The clinical records and radiographs of 112 patients who undergone orthognathic surgery between 2014 and 2021 were retrospectively analyzed. Patients’ demographics, follow-up period, type of malocclusion and operation were recorded. All surgical complications were evaluated into two groups as intraoperative or postoperative complications. Results: The mean age of 112 patients (69 female, 43 male) was 24.4 ± 5.5 (ranging from 16 to 47). The most frequent intraoperative complication was the bad split (5 cases, 4.5%), followed by severe hemorrhage due to rupture of facial artery (1 case, 0.9%), dissection of inferior alveolar nerve (1 case, 0.9%), and dental damage (1 case, 0.9%). The most common postoperative complication was the neurosensorial deficit (29 cases, 25.9%), followed by infection (6 cases, 5.4%), extraoral scar formation (5 cases, 4.5%), fracture of fixation material (2 cases, 1.8%), maxillary non-union (2 cases, 1.8%), postoperative nasal hemorrhage (1 case, 0.9%), and failure of fixation material (1 case, 0.9%). There were no fatal complications. Conclusion: Although the wide range of complications related to orthognathic surgery is reported both in our study and the literature, the frequency of these appears to be uncommon. However, in order to manage the complications of the operation properly, through knowledge and experience are essential.Amaç: Bu çalışmanın amacı, ortognatik cerrahi uygulanan hastalarda operasyon sırasında ve sonrasında ortaya çıkan komplikasyonların insidansını değerlendirmektir. Yöntemler: 2014-2021 yılları arasında ortognatik cerrahi operasyonu uygulanan 112 hastanın klinik kayıtları ve radyografileri retrospektif olarak incelendi. Hastaların demografik verileri, takip süresi, maloklüzyon ve operasyon tipi kaydedildi. Tüm cerrahi komplikasyonlar, operasyon sırasında ve sonrasında olmak üzere iki grupta incelenerek değerlendirildi. Bulgular: 112 hastanın (69 kadın, 43 erkek) ortalama yaşı 24,4 ± 5,5 (16-47 arasında) idi. Operasyon sırasında en sık görülen komplikasyon kötü kırık oluşumuydu (5 vaka, %4,5) ve bunu fasiyal arter rüptürüne bağlı olarak görülen şiddetli kanama (1 vaka, %0,9), inferior alveolar sinir diseksiyonu (1 vaka, %0,9) ve dental hasar (1 vaka, %0,9) takip etti. Operasyon sonrasında en sık karşılaşılan komplikasyon ise nörosensoriyel bozukluktu (29 vaka, %25,9) ve bunu enfeksiyon gelişimi (6 vaka, %5,4), ekstraoral skar oluşumu (5 vaka, %4,5), fiksasyon materyalinin fraktürü (2 vaka, %1,8), maksillada osteotomi hattının kemikleşmemesi (2 vaka, %1,8), postoperatif nazal hemoraji (1 vaka, %0,9) ve fiksasyon materyalinin kaybı (1 vaka, %0,9) izledi. Hiçbir hastada hayatı tehdit edici bir komplikasyon ile karşılaşılmadı. Sonuç: Bu çalışmada ve literatürde ortognatik cerrahi ile ilişkili olarak çeşitli komplikasyonlar bildirilse de, bu komplikasyonların görülme sıklığı azdır. Ancak, operasyonda ortaya çıkabilecek komplikasyonların uygun bir şekilde yönetilebilmesi için yeterli bilgi ve deneyime sahip olmak büyük önem taşımaktadır

    A global survey on the use of the international classification of diseases codes for metabolic dysfunction‑associated fatty liver disease

    No full text
    Background: With the implementation of the 11th edition of the International Classification of Diseases (ICD-11) and the publication of the metabolic dysfunction-associated fatty liver disease (MAFLD) nomenclature in 2020, it is important to establish consensus for the coding of MAFLD in ICD-11. This will inform subsequent revisions of ICD-11. Methods: Using the Qualtrics XM and WJX platforms, questionnaires were sent online to MAFLD-ICD-11 coding collaborators, authors of papers, and relevant association members. Results: A total of 890 international experts in various fields from 61 countries responded to the survey. We also achieved full coverage of provincial-level administrative regions in China. 77.1% of respondents agreed that MAFLD should be represented in ICD-11 by updating NAFLD, with no significant regional differences (77.3% in Asia and 76.6% in non-Asia, p = 0.819). Over 80% of respondents agreed or somewhat agreed with the need to assign specific codes for progressive stages of MAFLD (i.e. steatohepatitis) (92.2%), MAFLD combined with comorbidities (84.1%), or MAFLD subtypes (i.e., lean, overweight/obese, and diabetic) (86.1%). Conclusions: This global survey by a collaborative panel of clinical, coding, health management and policy experts, indicates agreement that MAFLD should be coded in ICD-11. The data serves as a foundation for corresponding adjustments in the ICD-11 revision

    Non-invaziv TensorTip MTX hemoglobin ölçümü validasyon çalışması

    No full text
    Objective: Point of care devices are fast and easy to use but their true potential is still waiting to come up. TensorTip MTX is a non-invasive medical device can measure various bioparameters, including hemoglobin. Purpose of this study is to measure the correlation between TensorTip MTX and our routine laboratuvary analysis of hemoglobin and to see that device is useable in emergency department settings for situations like gastroinstestinal bleeding and acute traumatic hemorrhages. Methods: In the month after the ethical board approval, we conduct our study in 147 patients. Their hemoglobin levels were already measured while their course of emergency department visit. To gather accurate data of hemoglobin measurement of TensorTip MTX, device put on the ring finger of the patients and wait at least 45 seconds for measurement. All measurement documented and recorded by researcher. Measurements from blood samples and TensorTip MTX device are compared with intraclass correlation coefficient (ICC) and Pearson correlation coefficient. Results: In 147 patients; 61.2% (n=90) were male, 38.8% (n=57) were female and ages are between 18 and 89. Mean age is 55.72±20.30 years; 23.1% (n=34) of them is under 35 years old, 76.9% (n=113) over 35 years. Statistically, the correlation between hemoglobin levels measured by the reference method and TensorTip was found to be 42.4%, which is statistically signficant (p=0.001; p<0.01) [ICC: 0.424; 95% confidence interval (CI): 0.281-0.548]. Correlation between hematocrit level measurements is 46.9% significantly compatible (p=0.001; p<0.01) (ICC: 0.429; 95% CI: 0.333-0.586). Conclusion: Our study showed that correlation between reference measurement and TensorTip MTX device is fair (ICC: 0.424 for hemoglobin and 0.429 for hematocrit). Further studies needed to determine that this device is suitable or not to identify the need of blood transfusion and management of patients with acute hemorrhages in the emergency settings for now.Amaç: Hasta başı ölçüm yapabilen cihazların kullanımı kolay ve hızlıdır ancak tam potansiyelleri halen ortaya çıkmamıştır. TensorTip MTX non-invaziv olarak hemoglobin de dahil olmak üzere pek çok vital parametreyi ölçebilen bir cihazdır. Bu çalışmanın amacı TensorTip MTX adlı cihazın ölçtüğü hemoglobin değerlerini rutin laboratuvar analizleri ile karşılaştırarak, bu cihazın acil serviste gastrointestinal kanama ve akut travmatik kanama gibi durumlarda kullanılabilirliğini değerlendirmektir. Yöntem: Etik kurul onayı alındıktan sonraki ay içinde çalışmaya dahil edilen 147 hasta üzerinde ölçüm yapılmıştır. Acil servise başvuruları sorasındaki süreçte venöz kandan hemoglobin değerleri ölçülmüştür. TensorTip MTX cihazı ile doğru ölçüm yapabilmek için, 45 saniye boyunca hastaların yüzük parmağından ölçüm yapılmıştır. Toplanan her veri araştırmacı tarafından kaydedilmiştir. Kan örneklerinden ve TensorTip MTX ile ölçülen hemoglobin seviyeleri sınıf içi korelasyon katsayısı (ICC) ve Pearson korelasyon katsayısı ile karşılaştırılmıştır. Bulgular: Toplamda 147 hastanın %61,2’si (n=90) erkek, %38,8’i (n=57) kadın ve yaş aralığı 18 ile 89 arasındaydı. Ortalama yaş 55,72±20,30; %23,1’i (n=34) 35 yaş altındaydı, %76,9’u (n=113) 35 yaşın üstündeydi. Referans değer ile TensorTip hemoglobin ölçümleri arasındaki %42,4 düzeyinde istatistiksel olarak anlamlı uyum saptandı (p=0,001; p<0,01) [ICC: 0,424; %95 güven aralığı (CI): 0,281-0,548]. Referans ile TensorTip hematokrit ölçümleri arasındaki %46,9 düzeyinde istatistiksel olarak anlamlı uyum gözlendi (p=0,001; p<0,01) (ICC: 0,429; %95 CI: 0,333-0,586). Sonuç: Çalışmamız gösterdi ki referans ölçümler ile TensorTip MTX cihazı arasındaki korelasyon orta düzeydedir (hemoglobin için ICC: 0,424, hematokrit için ICC: 0,429). Eldeki verilerle şu an için kan transfüzyonu yapılmasına karar vermekte ve akut kanamalı hastaların acil servis yönetiminde bu cihazların kullanımının uygunluğunu değerlendirmek için daha fazla çalışmaya ihtiyaç duyulmaktadır

    0

    full texts

    1,249

    metadata records
    Updated in last 30 days.
    İstanbul Sağlık ve Teknoloji Üniversitesi Kurumsal Akademik Arşivi
    Access Repository Dashboard
    Do you manage Open Research Online? Become a CORE Member to access insider analytics, issue reports and manage access to outputs from your repository in the CORE Repository Dashboard! 👇