Informes de la Construcción (E-Journal)
Not a member yet
    5825 research outputs found

    Evaluación de la fuerza de anclajes de andamios de fachada

    Get PDF
    The resistance of the anchors to the facade of collective protection (CP) or building aids (MAE) is an essential point of the stability of these elements, which in many cases is unknown. There have been numerous studies on resistance and behavior of the braces to concrete structures. But hardly any studies analyzing the strength of masonry anchors, much less masonry with decades of service in real situations: buildings that have to intervene and must anchor CP and MAE to its factories. In this study we have evaluated the pullout resistance of cancer plastic plugs inserted into staying in masonry building already built. The results were compared with those of other investigators and allowed to assess the requirements of the standard UNE-EN 12810-1 regarding the disposition and removal of scaffolding anchors to the facade.La resistencia de los anclajes a fachada de las protecciones colectivas (PC) o de los medios auxiliares de edificación (MAE) constituye un punto esencial de la estabilidad de esos elementos, que en muchos casos se desconoce. Se han realizado numerosos estudios acerca de la resistencia y del comportamiento de los anclajes metálicos a estructuras de hormigón. Sin embargo apenas existen trabajos que analicen la resistencia de anclajes a fábricas de albañilería y mucho menos a fábricas de albañilería con decenios de antigüedad en situaciones reales: edificios en los que hay que intervenir y es preciso anclar PC y MAE a sus fábricas. En este trabajo se ha evaluado la resistencia a arrancamiento de cáncamos insertados en tacos de plástico alojados en fábricas de albañilería de edificación ya construidas. Los resultados obtenidos se han comparado con los de otros investigadores y han permitido valorar las prescripciones de la norma UNE-EN 12810-1 relativas a la disposición y separación de anclajes de los andamios a fachada

    Armado Óptimo de Secciones de Hormigón Posteso

    Get PDF
    The amount of passive reinforcement to be provided in the ultimate limit state is computed by means of RSD (Reinforcement Sizing Diagrams) taking into account the presence of active reinforcement, for a particular range of pairs active steel area – active steel eccentricity (Ap – dp) that meet the requirements imposed by the serviceability limit state. The solution that provides the minimum total cost of both active and passive steel is selected.Para un rango de valores de área de armadura activa y de excentricidad que cumplen los requisitos de tensión impuestos por el estado límite de servicio, se evalúa la armadura pasiva necesaria en estado límite último mediante la técnica RSD (Reinforcement Sizing Diagrams) teniendo en cuenta la presencia de la armadura activa. Se selecciona la solución que conduce a un valor mínimo del coste total de armado pasivo y activo

    Índices

    Get PDF

    Impacto energético y emisiones de CO2 del edificio con soluciones alternativas de fachada

    Get PDF
    This work uses a simplified life cycle analysis (LCA) methodology to explore the impact reduction potential in the design phase in terms of primary energy and greenhouse gas emissions for a given building using several façade solutions. This is achieved through a review of several design criteria (wall characteristics, insulation level, reposition rate and component durability) and their combinations, and analizing how they relate to the selected impacts for the production and use stages in the building life cycle. Results show that both emissions and energy embedded into the building materials or the building process are of great relevance and impact of emissions is comparable to those due to the use stage. This work concludes that, for a given building, a significant impact reduction on the selected impact indicators can be achieved by a careful selection of building solutions and durability strategies (through maintenance or refurbishment) in the design phase.El artículo emplea una simplificación de la metodología del análisis de ciclo de vida (ACV) para explorar en fase de proyecto el potencial de reducción de impactos, en términos de energía primaria y emisiones de gases de efecto invernadero, para diferentes soluciones de fachada y estrategias de durabilidad. Se evalúan a nivel de edificio varias alternativas de diseño de una fachada tipo (configuración del muro, aislamiento, frecuencia de reposición y durabilidad) y se analiza su repercusión en los impactos seleccionados para las etapas de producción y uso del edificio. Se concluye la importancia de la energía y emisiones incorporadas a los materiales y procesos de construcción en los impactos totales, siendo las emisiones en esas fases comparables a las de la fase de uso. Se concluye la posibilidad de reducir significativamente los impactos mediante una selección cuidadosa de los criterios de diseño y estrategias apropiadas de durabilidad, mantenimiento y rehabilitación

    La costilla laminar del Instituto de Ciencias de la Construcción Eduardo Torroja (IETcc-CSIC). Levantamiento mediante láser-escáner y evaluación estructural

    Get PDF
    The outer chapel built in the Alarife’s courtyard of the Eduardo Torroja Institute was designed as a riblike sheet in 1969 as a symbol of the possibilities that reinforced concrete technology offered at that time. The result was a sheet of reinforced concrete 10 m long and 6.5 m high with thicknesses ranging between 6 and 40 cm and defined from a guideline whose form Lemniscate of Bernoulli. This article studies the behavior that this structure has had 45 years after its construction. A novel tool such as laserscanner has been used for volumetric survey of the three-dimensional structure to perform the calculation using FEM modeling. An evaluation of the damages observed in the sheet, a study of the strains and an analysis of its resistant behavior and structural safety have been made. From the research conducted it can be concluded that the construction can be kept in service performing repairs and maintenance.La capilla exterior construida en el patio de los Alarifes del Instituto de Ciencias de la Construcción Eduardo Torroja fue concebida en forma de «costilla laminar» en 1969 como símbolo de las posibilidades que la tecnología del hormigón armado ofrecía en aquella época. El resultado fue una lámina de hormigón armado de 10 m de longitud y 6,5 m de altura con espesores que varían entre 6 y 40 cm y definida a partir de una directriz en forma de Lemniscata de Bernoulli. Este artículo estudia el comportamiento que ha tenido esta estructura 45 años después de su construcción. Se ha utilizado una herramienta novedosa como el láser-escáner para el levantamiento volumétrico de la estructura y la modelización tridimensional para realizar el cálculo mediante MEF. Se ha hecho una evaluación de los desperfectos observados en la lámina, un estudio de las deformaciones sufridas y un análisis de su comportamiento resistente y seguridad estructural. A partir de la investigación realizada puede concluirse que la construcción puede mantenerse en servicio realizando las reparaciones y el mantenimiento adecuados

    Método de Aproximación Catenaria en el diseño de estructuras antifuniculares

    Get PDF
    This paper describes a new methodology for solving a typical problem in the design of antifunicular structures: how a equilibrium configuration can be obtained with initial geometrical constraints. In the seventies the Force Density Method -FDM- was introduced for the research of an equilibrium position. This method is nowadays being used successfully for both tension structures and antifunicular structures. However, in the second ones, the problem of balance turns non-lineal and must be solved in an iterative manner through successive tests. By means of the so-called Catenary Aproximation Method -CAM, conceived as an assistance tool in the application of the FDM to antifuniculars structures, it is possible to obtain in a simple way a equilibrium configuration with some geometric characteristics previously established.Este artículo describe una nueva metodología para resolver un problema típico del diseño de estructuras antifuniculares: cómo obtener una configuración de equilibrio partiendo de condicionantes geométricos iniciales. En los años 70 se introdujo el Método de Densidad de Fuerzas –MDF– para la búsqueda de la configuración de equilibrio, método que hoy en día sigue utilizándose con éxito tanto en estructuras tensadas como en estructuras antifuniculares. Sin embargo, en las segundas, el problema de equilibrio se vuelve no-lineal y debe resolverse de una manera iterativa, mediante pruebas sucesivas. A través del que hemos denominado Método de Aproximación Catenaria –MAC–, concebido como herramienta de ayuda en la aplicación del MDF a estructuras antifuniculares, es posible obtener de manera sencilla una forma de equilibrio con unas características geométricas previamente establecidas

    Eduardo Torroja y la International Association for Shell and Spatial Structures (IASS)

    Get PDF
    Eduardo Torroja’s legacy doesn’t limit to his innovative designs, or to his contributions to concrete structures and their codes development. Throw his life, he founded, or contributed to found, several associations, national and international, which as IASS (1959) are working nowadays leading the progress of civil and architectural construction.El legado de Eduardo Torroja no se limita a sus innovadores proyectos, o a sus aportaciones al cálculo y desarrollo del hormigón armado y pretensado. A lo largo de su vida, fundó, o contribuyó a fundar, diversas asociaciones, nacionales e internacionales que, como la IASS (1959), continúan vivas liderando el progreso de la construcción civil y arquitectónica

    Modelo de predicción de la vida útil de la edificación patrimonial a partir de la lógica difusa

    Get PDF
    We seek a procedure to identify and assess the factors that affect the vulnerability and risks affecting the building and validate a model to calculate service life. We would thus have a prediction method that would be very useful in the process of maintenance and conservation of the built heritage. The problem is that in analyzing the various methods currently used to predict events in the field of heritage conservation, we find that such methods are at the threshold of uncertainty. For this reason, we have chosen to work with the theory of fuzzy sets (fuzzy set), as most appropriate tool. When generated prediction model based mathematics, what we have called FBSL (Fuzzy building service life) and provide satisfactory results, when predicting the building service life.Buscamos un procedimiento que permita determinar y valorar los factores que inciden sobre la vulnerabilidad y riesgos que afectan al edificio y validar un modelo para poder calcular su vida útil. Tendríamos así un método de predicción que resultaría de mucha utilidad en los procesos de mantenimiento y conservación del patrimonio edificado. El problema es que al analizar las diversas metodologías que actualmente se utilizan para la predicción de hechos en el campo de la conservación del patrimonio, nos encontramos con que tales métodos se hallan en el umbral de la incertidumbre. Por esta causa, hemos optado por trabajar con la teoría de conjuntos difusos (Fuzzy set), como herramienta más adecuada. Al modelo de predicción generado con base matemática, lo hemos denominado FBSL (Fuzzy building service life) y ofrece unos resultados satisfactorios, a la hora predecir la vida útil del edificio

    Evaluación de la tasa de infiltraciones de aire en edificios del centro histórico de Oporto

    Get PDF
    This work is part of a major investigation the authors are undertaking aiming to evaluate the energy performance of different retrofitting strategies for housing buildings, in order to establish preferential criteria of intervention according to its climate zone location, morphology, constructive features and patrimonial values. In the historic centre of Oporto, one of the major actions resides on a significant reduction in the heating loads of these distinctive buildings by decreasing the windows infiltration rate. To be able to accurate this potential for energy savings, in situ measurements of the infiltration rate of this houses at present were required, previous to a possible intervention. This article presents the data obtained using a fan pressurization method in two non-refurbished characteristic buildings of the Oporto’s Historic Centre, and analyses the results obtained for both a typical sash window and a casement window. Some relations between these infiltration rates and the buildings morphological and typological characteristics are considered.Este trabajo forma parte de una investigación mayor que los autores están llevando a cabo y que tiene como objetivo evaluar la eficiencia energética de diferentes estrategias de rehabilitación de edificios de viviendas, con el fin de establecer criterios preferenciales de intervención de acuerdo a la zona climáticas donde se ubica, a la morfología de los edificios, a sus características constructivas y a sus valores patrimoniales. En el centro histórico de Oporto, una de las principales acciones consistiría en la reducción significativa de la demanda de calefacción en los edificios de viviendas que lo caracterizan, mediante la disminución de la tasa de infiltración de las ventanas. Para poder precisar este potencial de ahorro de energía, se requieren mediciones in situ de las tasas de infiltración de las citadas viviendas en su estado actual, previamente a una posible intervención. En este artículo se presenta los resultados obtenidos en los ensayos de presurización llevados a cabo en dos edificios característicos del Centro Histórico de Oporto que no han sido objeto aún de rehabilitación, y se analizan los valores alcanzados para ventanas típicas de guillotina y abatibles. Además, se estudian las relaciones entre los valores de estas tasas y las características morfológicas y tipológicas de los edificios

    Evaluación de barandillas de seguridad de obras apoyadas en puntales

    Get PDF
    To protect themselves against fall hazards in a slab-column frame, workers use the row of shoring jacks installed at 1 m from the edge as supports for on-site built guardrails. Inspectors of the Quebec Workers Compensation Board (Commission de la santé et de la sécurité du travail (CSST)) have expressed concern about the safety and compliance of these on-site built guardrails with the Quebec Safety Code for the Construction Industry (S-2.1, r.4). Some workers have also inquired if the shoring jack can be used as an anchor for a travel restraint system. The present study describes how an evaluation method and a test protocol have been used to verify if guardrails built on-site, with shoring jacks as supports, are safe and comply with the requirements of S-2.1, r.4 and if the shoring jack can be used as an anchor point for a travel restraint system. The results of the study show 1) guardrails built on site with shoring jacks as supports, are safe and comply with S-2.1, r.4 and 2) shoring jacks used as supports for guardrails must not be used as an anchor for a travel restraint system.Para la protección contra el peligro de caída en altura durante la ejecución de la estructura de un edificio, los trabajadores utilizan puntales acodalados a dos forjados y situados a 1 metro del borde de forjado como apoyo de las barandillas de seguridad. Inspectores de la Quebec Workers Compensation Board (Commision de la santé et de la sécurité du travail (CSST)) han expresado su preocupación por la seguridad y el cumplimiento de estos sistemas de protección en la construcción conforme al Código de Seguridad de Quebec para la industria de la construcción (S-2.1, R.6). Así mismo algunos trabajadores han mostrado su inquietud sobre la utilización de los puntales como sistemas para limitar el desplazamiento. El presente estudio describe un método de evaluación y un procedimiento de ensayo que se han utilizado para verificar si las barandillas de seguridad apoyadas en puntales acodalados son seguras y cumplen con los requisitos de S-2.1, R.6; y si el puntal acodalado puede ser utilizado como punto de anclaje del sistema para limitar los desplazamientos. Los resultados del estudio muestran 1) las barandillas de seguridad apoyadas en puntales acodalados son seguras y cumplen con S-2.1, R.6 y 2) los puntales acodalados utilizados como apoyo de las barandillas de seguridad no deben ser usados como apoyos para sistemas con desplazamientos limitados

    4,188

    full texts

    5,825

    metadata records
    Updated in last 30 days.
    Informes de la Construcción (E-Journal)
    Access Repository Dashboard
    Do you manage Open Research Online? Become a CORE Member to access insider analytics, issue reports and manage access to outputs from your repository in the CORE Repository Dashboard! 👇