Retention clips cirucenferenciais associated with CuAlZn with docking was used in removable partial overdentures
The overdentures can be defined as total or partial removable dentures that cover root or osseo integrated implants rehabilitating the whole dentition. The mechanical retention in the removable partial overdentures (RPOs) is obtained through the use of cast clasps and attachments. This biomechanical principle has a great importance, since is inwardly
associated with long term behavior and clinical performance of prosthesis and consequently, with comfort and satisfaction of the patients. So, the aim of this study was to assess the
retention of metallic framework with simple circumferential claps associated intraradicular retainer with attachment type ERA (Extra coronal Resilient Attachment, Sterngold Implamed,
Attleboro, EUA) in function of the metals based cobalt-chromium alloy (Co-Cr), titanium commercially pure (Ti cp) and nickel-chromium with titanium alloy (Ni-Cr with Ti), of the
retentive undercuts of 0,25mm and 0,75mm and in function of the time of use in each simulated period (initial, 6 months, 1, 2, 3, 4 e 5 years). Through of metallic matrices representing a partially edentulous mandibular right hemi-arch segment constituted by the crown of the first molar, root of the inferior canine and with the absent of the premolars, were
made 60 metallic frameworks being obtained 03 groups of each metal and subgroups representative of the 0,25mm and 0,75mm retentive undercuts of the circumferential clasp
(totalizing 10 samples in each subgroup). Acrylic denture bases were constructed on the denture space and on the canine root that anchored the attachments and these received retentive capsules in the gray color of the system. Previously the mechanic tests, radiographic exams of the Ti cp frameworks were realized with the aim of detecting possible casting defects that could avert the posterior use. Next, the samples were mechanically tested simulating the insertion and removal of the framework using the testing apparatus designed at the Ribeirão Preto School of Dentistry (Testing apparatus, São Paulo University, Ribeirão Preto, Brazil), representing 5 years of simulated used. To simulate the intraoral conditions and realize the tests, a gadget fulfilled with artificial saliva was adapted in the testing apparatus.
The retentive force data were recorded and submitted linear regression analysis and analysis of variance (ANOVA) to gauge a presence or not of significant differences and applied the Tukey complementary test 5% to comparison of the differences between the groups and subgroups. The groups of Ni-Cr with Ti and Co-Cr samples obtained most retentive mean
with significant differences to group of Ti cp samples that obtained least retentive mean in every periods of time analyzed. To groups Ni-Cr with Ti and Co-Cr samples there was not significant difference of retention between the times analyzed free-standing of retentive undercuts (p > 0,05). In the group Ti cp samples there was significant difference of retention between the times analyzed just to subgroup samples with 0,75mm undercuts (p < 0,05). The Ni-Cr with Ti and Co-Cr samples with 0,75mm undercuts presented the most retentive mean and the Co-Cr samples with 0,25mm undercuts presented retention mean intermediate between biomechanical design in every periods of time analyzed. The Ti cp samples with 0,25mm undercuts presented the least retentive mean until second year of the analyze and the
Ti cp samples with 0,75mm undercuts presented the least retentive mean of third until fifth year of the analyse. The circumferential claps casting in Ti cp used in 0,75mm undercuts have potential risk of fractures, mainly after the 2o year of useAs overdentures (sobredentaduras) podem ser definidas como próteses removíveis totais ou parciais, que cobrem raízes ou implantes osseointegrados reabilitando toda a dentição. A
retenção mecânica nas overdentures parciais removíveis (OPRs) é obtida por meio da utilização combinada de grampos fundidos e encaixes. Este princípio biomecânico é de grande importância, visto que está intimamente relacionado com o comportamento e o desempenho clínico em longo prazo das próteses e conseqüentemente, com o conforto e satisfação dos pacientes. Assim, o objetivo deste estudo foi avaliar a retenção de estruturas com grampos circunferenciais simples associadas a retentores intra-radiculares com encaixe
do tipo ERA (Extra coronal Resilient Attachment, Sterngold Implamed, Attleboro, EUA) em função dos metais à base de cobalto-cromo (Co-Cr), titânio comercialmente puro (Ti cp) e
níquel-cromo com titânio (Ni-Cr com Ti), dos contornos retentivos de 0,25mm e 0,75mm e em função do tempo de uso em cada período simulatório (inicial, 6 meses, 1, 2, 3, 4 e 5 anos). A partir de matrizes metálicas representativas de uma hemi-arcada inferior direita parcialmente desdentada com as presenças da coroa do primeiro molar, raiz do canino e com
os pré-molares ausentes, foram confeccionadas 60 estruturas metálicas sendo obtidos 3 grupos de cada metal e subgrupos representativos dos contornos retentivos de 0,25mm e 0,75mm do grampo circunferencial (perfazendo 10 amostras por subgrupo). Foram confeccionadas bases protéticas sobre o espaço protético e raiz do canino que ancoraram os encaixes e estes receberam as cápsulas retentivas de cor cinza do sistema. Previamente aos ensaios mecânicos,
exames radiográficos das estruturas em Ti cp foram realizados para detectar possíveis defeitos de fundição que pudessem inviabilizar o uso posterior. Em seguida, as amostras foram
ensaiadas mecanicamente simulando movimentos de inserção e remoção da estrutura utilizando uma máquina de ensaios projetada na Faculdade de Odontologia de Ribeirão Preto
(Máquina de Ensaios, Universidade de São Paulo, Ribeirão Preto, Brasil), representando o uso simulado de 5 anos. Para simular as condições intrabucais e realizar os ensaios, um
dispositivo preenchido com saliva artificial foi adaptado ao simulador. Os dados de força retentiva foram registrados e submetidos à análise de regressão linear e à análise de variância (ANOVA) para aferir a presença ou não de diferenças estatisticamente significativas e aplicado o teste de Tukey à 5% de probabilidade para comparação das diferenças entre os grupos e subgrupos. As amostras dos grupos em Ni-Cr com Ti e Co-Cr obtiveram as maiores
médias de retenção com diferenças estatisticamente significantes para as amostras do grupo em Ti cp que obtiveram as menores médias de retenção em todos os períodos de tempo analisados. Para os grupos das amostras em Ni-Cr com Ti e Co-Cr não houve diferença de retenção estatisticamente significante entre os tempos analisados independente dos contornos retentivos (p > 0,05). No grupo das amostras em Ti cp houve diferença de retenção
estatisticamente significante entre os tempos analisados apenas para as amostras do subgrupo com contorno retentivo de 0,75mm (p < 0,05). As amostras em Ni-Cr com Ti e em Co-Cr com contorno retentivo de 0,75mm apresentaram as maiores médias de retenção e as amostras em Co-Cr com contorno retentivo de 0,25mm apresentaram retenções médias intermediárias entre os desenhos biomecânicos em todos os períodos de tempo analisados. As amostras em Ti cp
com contorno retentivo de 0,25mm apresentaram as menores médias de retenção até o segundo ano de análise e as amostras em Ti cp com contorno retentivo de 0,75mm
apresentaram as menores médias de retenção do terceiro ao quinto ano de análise. Os grampos circunferenciais fundidos em Ti cp utilizados em contornos retentivos de 0,75mm tem um risco potencial de fraturas, principalmente após o 2o ano de us
Fatigue strength of commercially pure titanium and TI-6Al-4V alloy in different storage media
Orientador: Guilherme Elias Pessanha HenriquesDissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de PiracicabaResumo: A fadiga é responsável por 90% das falhas de infra-estruturas metálicas em serviço. Esse fenômeno está intimamente relacionado às alterações superficiais e ocorre devido à aplicação de esforços cíclicos. As PPRs sofrem fadiga devido às constantes inserções e remoções e durante o próprio ato mastigatório. Devido a propriedades como biocompatibilidade e resistência mecânica, tem-se introduzido o uso do titânio e suas ligas na confecção de coroas e próteses, sendo consideradas susceptíveis de alterações superficiais devido ao uso de soluções fluoretadas. O propósito deste estudo foi avaliar, comparar e analisar a vida em fadiga do titânio comercialmente puro e da liga Ti-6Al-4V em diferentes meios de armazenagem (sem a presença de meios; em saliva artificial; e, em saliva artificial fluoretada). Foram confeccionadas trinta amostras para cada um dos materiais, com geometria semelhante a um halteres e 2,3 mm de diâmetro na porção central, obtidas por fundição odontológica, em máquina de fundição Rematitan (Rematitan - Dentaurum J.P. Winkelstroeter KG- Pforzhein - Alemanha). O ensaio de resistência à fadiga foi conduzido numa máquina de ensaios universal (MTS - Materials Testing System, Test Star II), com carga 30% abaixo e calculada a partir do limite de escoamento a 0,2% de deformação. Após a fratura, o número de ciclos foi registrado e a superfície de fratura analisada sob microscopia eletrônica de varredura (M.E.V.). Os resultados indicaram que a liga Ti-6Al-4V obteve 21,269.50 ciclos, contra 19,157.60 ciclos para o Ti c.p., e na presença das soluções esse número diminuiu drasticamente, sugerindo provável reação dos meios com os metais. Com base nos resultados obtidos, verificamos que: A liga Ti-6Al-4V obteve os maiores valores médios de resistência à fadiga, porém sem diferença estatisticamente significante em relação ao titânio puro, independente da presença dos meios de armazenagem. A presença das soluções de armazenagem diminuiu a resistência à fadiga para ambos materiais, com diferença estatisticamente significante em relação às amostras ensaiadas sem a presença dos meios. A solução de saliva artificial fluoretada pareceu mais agressiva. Entretanto, não houve diferença estatística em relação à solução de saliva artificialAbstract: The fatigue is responsible for 90% of metallic component failures during service. This phenomenon is closely related to superficial alteration and it occurs during cyclic stress application. Removable partial dentures (RPDs) are affected by fatigue due to cyclic mechanism of the masticatory system and the frequent insertion and removal. Because of unique and favorable properties, titanium and its alloys have been used in manufacturing crowns and bridges. However, it has been shown that preventive agents with fluoride probably affect titanium alloy surfaces. The aim of this study was to evaluate compare and analise the fatigue life of commercially pure titanium and Ti-6Al-4V alloy in different media (without media, artificial saliva and fluoride artificial saliva). For each alloy, thrirty dumb-bell rods 2.3 mm in diameter were.cast in Rematitan-System (Rematitan-Dentaurum IP. Winkelstroeter KG-Germany). The fatigue strength test was carried out with an universal testing machine (MTS- Materials Testing System - Test Star II), using a load 30 % lower than the calculated yield strength at a 0.2% offset. After failure, the number of cycles were recorded and the fracture surfaces were examined with a scanning electron microscope (S.E.M.). The mean values indicated that Ti-6Al-4V alloy achieved 21,269.50 cycles against 19,151.60 cycles for the c.p. titanium, and, when the solutions were present, the number of cycles was drastically reduced, probably due to pits caused by superficial reactions, as showed in S.E.M. analyses. It was observed that: Ti-6Al-4V alloy had the highest mean values of fatigue strenght, however, there were no siglificant differences as regards c.p. titanium. free-standing
the presence or absence of media; the solutions reduced fatigue strength for both alloys, with statistically significant differences to specimens tested without the solutions; the fluoride solution was the most harmful agent, but there were no significant differences between fluoride solution and artificial salivaMestradoProtese DentalMestre em Clínica Odontológic
Influencia da soldagem a laser no titanio comercialmente puro e titanio-aluminio-vanadio sobre a fadiga-corrosão em diferentes meios
Orientador : Guilherme Elias Pessanha HenriquesTese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de PiracicabaResumo: Aliado aos esforços cíclicos, determinados agentes à base de flúor podem atuar sobre as infra-estruturas de próteses, causando a fadiga. Assim, o propósito deste estudo foi avaliar, analisar e comparar a vida em fadiga-corrosão de amostras confeccionadas em titânio comercialmente puro e liga Ti-6AI-4V intactas e soldadas a laser, e ensaiadas em diferentes meios de armazenagem. Para cada metal, 60 amostras semelhantes a um halteres, com 2,3mm de diâmetro no segmento central, foram obtidas a partir do sistema de fundição Rematitan. Os ensaios de fadiga-corrosão foram realizados em máquina universal de ensaios (MTS - Test Star II) com carga 30% abaixo do limite de escoamento a 0,2% do deslocamento, e combinando três situações de armazenagem: sem imersão, com saliva artificial e com saliva artificial fluoretada. Após a fratura, o número de ciclos foi registrado e a superfície de fratura analisada em MEV. As amostras fraturadas foram subseqüentemente soldadas a laser, usinadas e ensaiadas novamente nas mesmas condições das amostras intactas. A análise de variância (ANOVA) e o teste de Tukey com 5% de probabilidade, indicaram redução no número de ciclos até a fratura (5674 - saliva artificial e 3948 ciclos - saliva fluoretada) quando as amostras foram ensaiadas na presença das soluções de armazenagem, com diferença estatisticamente significativa em relação às amostras ensaiadas sem os meios (16186 ciclos). O processo de soldagem a laser influenciou negativamente, diminuindo o número de ciclos até a fratura (6146 cicios), mostrando diferença estatisticamente significativa em relação às amostras intactas (11060 ciclos)Abstract: Stress cyclic and some prophylactics agents could affect infrastructure of prosthesis causing fatigue. So, the aim of this study was to evaluate, analyze and compare the corrosion-fatigue lives of specimen obtained in commercially pure titanium and Ti-6AI-4V alloy intacted and laser welded, tested in different storage environments. For each metal, 60 dumbbell rods, 2,3mm in diameter at the central segment, were obtained and casted in Rematitan system. Corrosion-fatigue life was carried out through a universal testing machine (MTS Test Star II) with a load 30% lower than the 0,2% offset yield strength and combining tree different environments: in air at. room temperature, with synthetic saliva and with fluoride synthetic saliva. After failure, the number of cycles were recorded, and the fracture surface was examined with an SEM. The specimen were then laser welded, grounded and tested again in the same conditions of the intact specimen. ANOV A and Tukey's multiple comparison test indicated that the number of cycles decreased in wet environments (5674 - synthetic saliva and 3948 cycles - fluoride saliva), with significant differences between the specimen tested in air at room temperature (16186 cycles). The process of laser welding affected negatively the corrosion-fatigue strength (6146 cycles), reducing the number of cycles showing significant differences between the intact specimen (11060 cycles)DoutoradoProtese DentalDoutor em Clínica Odontológic
Diagnóstico diferencial e sintomatologia da síndrome de EAGLE. Revisão de literatura.
Diagnóstico diferencial e sintomatologia da síndrome de EAGLE. Revisão de literatura
Going Beyond Counting First Authors in Author Co-citation Analysis
The present study examines one of the fundamental aspects of author co-citation analysis (ACA) - the way co-citation
counts are defined. Co-citation counting provides the data on which all subsequent statistical analyses and mappings
are based, and we compare ACA results based on two different types of co-citation counting - the traditional type that
only counts the first one among a cited work's authors on the one hand and a non-traditional type that takes into
account the first 5 authors of a cited work on the other hand. Results indicate that the picture produced through this non-traditional author co-citation counting contains more coherent author groups and is therefore considerably clearer. However, this picture represents fewer specialties in the research field being studied than that produced through the traditional first-author co-citation counting when the same number of top-ranked authors is selected and analyzed. Reasons for these effects are discussed
Variations on the Author
“Variations on the Author” discusses two of Eduardo Coutinho’s recent films (Um Dia na Vida, from 2010, and Últimas Conversas, posthumously released in 2015) and their contribution to the general question of documentary authorship. The director’s filmography is characterized by a consistent yet self-effacing form of authorial self-inscription: Coutinho often features as an interviewer that rather than express opinions propels discourses; an interviewer that is good at listening. This mode of self-inscription characterizes him as an author who is not expressive but who is nonetheless markedly present on the screen. In Um Dia na Vida, however, Coutinho is completely absent form the image, while Últimas Conversas, on the contrary, includes a confessional prologue that moves the director from the margins to the center of his films. This article examines the ways in which these works stand out in the filmography of a director who offers new insights into the notion of cinematic authorship
Appropriate Similarity Measures for Author Cocitation Analysis
We provide a number of new insights into the methodological discussion about author cocitation analysis. We first argue that the use of the Pearson correlation for measuring the similarity between authors’ cocitation profiles is not very satisfactory. We then discuss what kind of similarity measures may be used as an alternative to the Pearson correlation. We consider three similarity measures in particular. One is the well-known cosine. The other two similarity measures have not been used before in the bibliometric literature. Finally, we show by means of an example that our findings have a high practical relevance.information science;Pearson correlation;cosine;similarity measure;author cocitation analysis
Dispelling the Myths Behind First-author Citation Counts
We conducted a full-scale evaluative citation analysis study of scholars in the XML research field to explore just how different from each other author rankings resulting from different citation counting methods actually are, and to demonstrate the capability of emerging data and tools on the Web in supporting more realistic citation counting methods. Our results contest some common arguments for the continued
use of first-author citation counts in the evaluation of scholars, such as high correlations between author rankings by first-author citation counts and other citation
counting methods, and high costs of using more realistic citation counting methods that are not well-supported by the ISI databases. It is argued that increasingly available digital full text research papers make it possible for citation analysis studies to go beyond what the ISI databases have directly supported and to employ more
sophisticated methods
- …