External ring fixators: an overview.
External fixation is widely used in the fixation of fractures and limb deformities. The mechanical characteristics of a specific external fixator are major factors in determining the biomechanical environment at a fracture/osteotomy site and, hence, affect the healing process. Although the optimal biomechanical environment for healing of a fracture or an osteotomy is unknown, a specific range of interfragmentary motion exists which promotes healing. It is therefore desirable that the mechanics of an external fixator can be manipulated to enable the surgeon to control the range of interfragmentary motion. The characteristics of an external fixator are defined by a large number of variables. Therefore, to gain control over the degree of interfragmentary motion, an understanding of the effect of each variable and how it interacts with the others to determine the overall characteristics of the device is required. For the past two decades, individual components and whole-frame configurations have been studied in depth. This article provides a summary of previous work concerning the mechanics of external ring fixators and how they affect the biomechanical environment at the fracture/osteotomy site
Going Beyond Counting First Authors in Author Co-citation Analysis
The present study examines one of the fundamental aspects of author co-citation analysis (ACA) - the way co-citation
counts are defined. Co-citation counting provides the data on which all subsequent statistical analyses and mappings
are based, and we compare ACA results based on two different types of co-citation counting - the traditional type that
only counts the first one among a cited work's authors on the one hand and a non-traditional type that takes into
account the first 5 authors of a cited work on the other hand. Results indicate that the picture produced through this non-traditional author co-citation counting contains more coherent author groups and is therefore considerably clearer. However, this picture represents fewer specialties in the research field being studied than that produced through the traditional first-author co-citation counting when the same number of top-ranked authors is selected and analyzed. Reasons for these effects are discussed
Variations on the Author
“Variations on the Author” discusses two of Eduardo Coutinho’s recent films (Um Dia na Vida, from 2010, and Últimas Conversas, posthumously released in 2015) and their contribution to the general question of documentary authorship. The director’s filmography is characterized by a consistent yet self-effacing form of authorial self-inscription: Coutinho often features as an interviewer that rather than express opinions propels discourses; an interviewer that is good at listening. This mode of self-inscription characterizes him as an author who is not expressive but who is nonetheless markedly present on the screen. In Um Dia na Vida, however, Coutinho is completely absent form the image, while Últimas Conversas, on the contrary, includes a confessional prologue that moves the director from the margins to the center of his films. This article examines the ways in which these works stand out in the filmography of a director who offers new insights into the notion of cinematic authorship
Appropriate Similarity Measures for Author Cocitation Analysis
We provide a number of new insights into the methodological discussion about author cocitation analysis. We first argue that the use of the Pearson correlation for measuring the similarity between authors’ cocitation profiles is not very satisfactory. We then discuss what kind of similarity measures may be used as an alternative to the Pearson correlation. We consider three similarity measures in particular. One is the well-known cosine. The other two similarity measures have not been used before in the bibliometric literature. Finally, we show by means of an example that our findings have a high practical relevance.information science;Pearson correlation;cosine;similarity measure;author cocitation analysis
Dispelling the Myths Behind First-author Citation Counts
We conducted a full-scale evaluative citation analysis study of scholars in the XML research field to explore just how different from each other author rankings resulting from different citation counting methods actually are, and to demonstrate the capability of emerging data and tools on the Web in supporting more realistic citation counting methods. Our results contest some common arguments for the continued
use of first-author citation counts in the evaluation of scholars, such as high correlations between author rankings by first-author citation counts and other citation
counting methods, and high costs of using more realistic citation counting methods that are not well-supported by the ISI databases. It is argued that increasingly available digital full text research papers make it possible for citation analysis studies to go beyond what the ISI databases have directly supported and to employ more
sophisticated methods
Yielding of the clamped-wire system in the Ilizarov external fixator.
This study demonstrates that the clamped-wire system used to suspend bones within an Ilizarov external fixator yields when the perpendicular load exceeds 50 N per wire. Cyclic loading was applied to tensioned wires clamped within an Ilizarov ring component, with steadily increasing load amplitude. Wires were tested at four initial tension settings. The amount of energy lost within the clamped-wire system per load cycle was calculated for every test. The results showed that there was a consistent trend to increasing non-recoverable energy loss per load cycle when peak loads exceed 50 N for all initial tension settings. A finite element (FE) model replicating the experimental conditions was performed to investigate the levels of stress within the loaded wires. The FE model analyses showed that high stresses were generated in the wires close to the clamping sites, and that the stress levels could reasonably be expected to exceed the material yield stress when loaded to about 55 N, for all initial tension settings. The results show that material yield, accompanied by some wire slippage through the clamps, is responsible for system yield, in agreement with previous studies. Although the initial wire tension has an appreciable effect on the wire stiffness, it did not affect the elastic load range of the clamped-wire system. To prevent yield of the clamped-wire system in practice, the fixator should be assembled with sufficient wires to ensure that the load transmitted to each wire by the patient does not exceed 50 N
koamabayili/VECTRON-author-checklist: VECTRON author checklist
We have done our best to complete the author checklist relating to the use of animals in the hut study. Note that the objective for the hut study was to evaluate the IRS treatment applications for residual efficacy against Anopheles mosquitoes, including the local An. coluzzii mosquito population. Cows were only used to attract mosquitoes into the huts and no tests were carried out directly on the cows. The author checklist is intended for use with studies where experiments are carried out on animals, which is why we have had such difficulty in completing this for the hut study, as many of the questions do not relate to how the cows were used
The effect of clamping a tensioned wire: implications for the Ilizarov external fixation system.
This study demonstrates that clamping a tensioned wire can cause a reduction in wire tension. Tension (about 1275 N) was applied to a wire that was subsequently clamped, using cannulated bolts, to the steel half-ring of an Ilizarov external fixator. The tension in the wire was monitored before, during and after clamping. The apparatus was disassembled and the deformations in the wire caused by the clamps were measured. This experiment was repeated 15 times. When the wire was clamped to the frame, the wire tension was reduced by 22 +/- 7 per cent (mean +/- standard deviation, SD). The drop in wire tension was linearly correlated (r = 0.96; p < 0.001) with the deformation caused by the bolts. A finite element (FE) model of the wire was also constructed. The model was pre-stressed (tensioned), and the clamping effect replicated. This analysis showed that clamping the wire could be considered to squeeze the wire outwards (like toothpaste from a tube) and so reduce its tension during fixator assembly. To assess the magnitude of this effect in the clinical situation, the FE model analysis was repeated to replicate clamping a 1.8-mm-diameter wire to a 180-mm-diameter steel Ilizarov ring component. The analysis showed that for these conditions the tension reduced by 8-29 per cent. The results of this study highlight a general engineering problem: how can a tensioned wire be secured to a structure without an appreciable loss of tension? If the performance of the structure depends on the wire tension, this performance will change when the wire is secured
- …