1,720,959 research outputs found

    Low-cost voltammetric sensor based on reduced graphene oxide anchored on platinum nanoparticles for robust determination of Favipiravir in real samples

    No full text
    © 2022 Elsevier B.V.This research describes a simple, sensitive, and disposable modified glassy carbon electrode constructed using platinum nanoparticles anchored on reduced graphene oxide nanocomposite as a conductive modifier (Pt@rGO/GCE) to detect an anti-coronavirus drug, Favipiravir (FAV). The as-synthesized nanocomposite was characterized by Fourier transform infrared spectroscopy (FTIR), X-ray diffraction (XRD), field emission scanning electron microscopy (FE-SEM), energy-dispersive X-ray spectroscopy (EDX), and atomic force microscopy (AFM). Under optimized conditions, the square wave voltammetry (SWV) method was used to determine trace amounts of FAV in real samples. The proposed electrode demonstrated a wide linear concentration range of 3.16 to 100.0 μM with a low detection limit (LOD) of 2.46 μM. Moreover, the developed electrode showed outstanding selectivity in the presence of several interferences with high repeatability and reproducibility. Finally, the developed electrode was applied to detect FAV in human plasma and pharmaceutical samples

    Fabric phase sorptive extraction combined with high performance liquid chromatography for the determination of favipiravir in human plasma and breast milk

    No full text
    A fast procedure obtained by the combination of fabric phase extraction (FPSE) with high performance liquid chromatography (HPLC) has been developed and validated for the quantification of favipiravir (FVP) in human plasma and breast milk. A sol-gel polycaprolactone-block-polydimethylsiloxane-block-polycaprolactone (sol-gel PCAP-PDMS-PCAP) coated on 100% cellose cotton fabric was selected as the most efficient membrane for FPSE in human plasma and breast milk samples. HPLC-UV analysis were performed using a RP C18 column under isocratic conditions. Under these optimezed settings, the overall chromatographic analysis time was limited to only 5 min without encountering any observable matrix interferences. Following the method validation pro-cedure, the herein assay shows a linear calibration curve over the range of 0.2-50 mu g/mL and 0.5-25 mu g/mL for plasma and breast milk, respectively. The method sensitivities in terms of limit of detection (LOD) and limit of quantification (LOQ), validated in both the matrices, have been found to be 0.06 and 0.2 mu g/mL for plasma and 0.15 and 0.5 mu g/mL for milk, respectively. Intraday and interday precision and trueness, accordingly to the International Guidelines, were validated and were below 3.61% for both the matrices. The herein method was further tested on real samples in order to highlight the applicability and the advantage for therapeutic drug monitoring (TDM) applications. To the best of our knowledge, this is the first validated FPSE-HPLC-UV method in human plasma and breast milk for TDM purposes applied on real samples. The validated method provides fast, simple, cost reduced, and sensitive assay for the direct quantification of favipiravir in real biological matrices, also appliyng a well-known rugged and cheap instrument configuration

    Going Beyond Counting First Authors in Author Co-citation Analysis

    Get PDF
    The present study examines one of the fundamental aspects of author co-citation analysis (ACA) - the way co-citation counts are defined. Co-citation counting provides the data on which all subsequent statistical analyses and mappings are based, and we compare ACA results based on two different types of co-citation counting - the traditional type that only counts the first one among a cited work's authors on the one hand and a non-traditional type that takes into account the first 5 authors of a cited work on the other hand. Results indicate that the picture produced through this non-traditional author co-citation counting contains more coherent author groups and is therefore considerably clearer. However, this picture represents fewer specialties in the research field being studied than that produced through the traditional first-author co-citation counting when the same number of top-ranked authors is selected and analyzed. Reasons for these effects are discussed

    Variations on the Author

    Get PDF
    “Variations on the Author” discusses two of Eduardo Coutinho’s recent films (Um Dia na Vida, from 2010, and Últimas Conversas, posthumously released in 2015) and their contribution to the general question of documentary authorship. The director’s filmography is characterized by a consistent yet self-effacing form of authorial self-inscription: Coutinho often features as an interviewer that rather than express opinions propels discourses; an interviewer that is good at listening. This mode of self-inscription characterizes him as an author who is not expressive but who is nonetheless markedly present on the screen. In Um Dia na Vida, however, Coutinho is completely absent form the image, while Últimas Conversas, on the contrary, includes a confessional prologue that moves the director from the margins to the center of his films. This article examines the ways in which these works stand out in the filmography of a director who offers new insights into the notion of cinematic authorship

    Appropriate Similarity Measures for Author Cocitation Analysis

    Get PDF
    We provide a number of new insights into the methodological discussion about author cocitation analysis. We first argue that the use of the Pearson correlation for measuring the similarity between authors’ cocitation profiles is not very satisfactory. We then discuss what kind of similarity measures may be used as an alternative to the Pearson correlation. We consider three similarity measures in particular. One is the well-known cosine. The other two similarity measures have not been used before in the bibliometric literature. Finally, we show by means of an example that our findings have a high practical relevance.information science;Pearson correlation;cosine;similarity measure;author cocitation analysis

    Dispelling the Myths Behind First-author Citation Counts

    Get PDF
    We conducted a full-scale evaluative citation analysis study of scholars in the XML research field to explore just how different from each other author rankings resulting from different citation counting methods actually are, and to demonstrate the capability of emerging data and tools on the Web in supporting more realistic citation counting methods. Our results contest some common arguments for the continued use of first-author citation counts in the evaluation of scholars, such as high correlations between author rankings by first-author citation counts and other citation counting methods, and high costs of using more realistic citation counting methods that are not well-supported by the ISI databases. It is argued that increasingly available digital full text research papers make it possible for citation analysis studies to go beyond what the ISI databases have directly supported and to employ more sophisticated methods

    Author Index

    No full text
    Nao informado

    koamabayili/VECTRON-author-checklist: VECTRON author checklist

    No full text
    We have done our best to complete the author checklist relating to the use of animals in the hut study. Note that the objective for the hut study was to evaluate the IRS treatment applications for residual efficacy against Anopheles mosquitoes, including the local An. coluzzii mosquito population. Cows were only used to attract mosquitoes into the huts and no tests were carried out directly on the cows. The author checklist is intended for use with studies where experiments are carried out on animals, which is why we have had such difficulty in completing this for the hut study, as many of the questions do not relate to how the cows were used
    corecore