1,720,963 research outputs found
Myopia Control Effect Is Influenced by Baseline Relative Peripheral Refraction in Children Wearing Defocus Incorporated Multiple Segments (DIMS) Spectacle Lenses
The aim of this study is to investigate if baseline relative peripheral refraction (RPR) influences the myopia control effects in Chinese myopic children wearing Defocus Incorporated Multiple Segments (DIMS) lenses. Peripheral refraction at 10°, 20°, and 30° nasal (10 N, 20 N, 30 N) and temporal (10 T, 20 T, 30 T) retina were measured at six-month intervals for children who participated in a 2-year randomized controlled trial. The relationship between the baseline peripheral refractions and myopia progression and axial length changes were analysed. A total of 79 children and 81 children in the DIMS and single vision (SV) group were investigated, respectively. In the DIMS group, more baseline myopic RPR spherical equivalent (SE) was associated with more myopic progression (10 N: r = 0.36, p = 0.001; 20 N: r = 0.35, p = 0.001) and greater axial elongation (10 N: r = −0.34, p = 0.001; 20 N: r = −0.29, p = 0.006) after adjusting for co-factors. In the SV group, baseline RPR had association with only myopia progression (10 N: r = 0.37, p = 0.001; 20 N: r = 0.36, p = 0.001; 30 N: r = 0.35, p = 0.002) but not with axial elongation after Bonferroni correction (p > 0.008). No statistically significant relationship was found between temporal retina and myopia progression or axial elongation in both groups. Children with baseline myopic RPR had statistically significant more myopia progression (mean difference around −0.40 D) and more axial elongation (mean difference 0.15 mm) when compared with the children having baseline hyperopic RPR in the DIMS group but not in the SV group. In conclusion, the baseline RPR profile may not influence future myopia progression or axial elongation for the SV lens wearers. However, DIMS lenses slowed down myopia progression and was better in myopia control for the children with baseline hyperopic RPR than the children with myopic RPR. This may partially explain why myopia control effects vary among myopic children. Customised myopic defocus for individuals may optimise myopia control effects, and further research to determine the optimal dosage, with consideration of peripheral retinal profile, is warranted
Changes in relative peripheral refraction in children who switched from single-vision lenses to Defocus Incorporated Multiple Segments lenses
Purpose: To investigate changes in relative peripheral refraction (RPR) associated with myopia progression in children who wore single-vision (SV) lenses for 2 years and switched to Defocus Incorporated Multiple Segments (DIMS) lenses in the third year versus children who wore DIMS lenses for 3 years. Methods: In the first 2 years, children were allocated randomly to wear either DIMS or SV lenses. In the third year, children in the DIMS group continued to wear these lenses, while those in the SV group were switched to DIMS lenses (Control-to-DIMS group). Central and peripheral refraction and axial length were monitored every 6 months. Results: Over 3 years, the DIMS group (n = 65) showed good myopia control and maintained a relatively constant and symmetrical RPR profile without significant changes. In the first 2 years, children who wore SV lenses (n = 55) showed asymmetrical RPR changes, with significant increases in hyperopic RPR at 20° nasal (N) (mean difference: 0.88 ± 1.06 D, p < 0.0001) and 30N (mean difference: 1.07 ± 1.09 D, p < 0.0001). The Control-to-DIMS group showed significant myopia retardation after wearing DIMS lenses in the third year. When compared with the RPR changes in the first 2 years, significant reductions in hyperopic RPR were observed at 20N (mean difference: −1.14 ± 1.93 D, p < 0.0001) and 30N (mean difference: −1.07 ± 1.17 D, p < 0.0001) in the third year. However, no significant difference between the RPR changes found in the nasal retina and temporal retina (p > 0.05) was noted in the third year. Conclusion: Symmetrical changes in RPR were found in children switching from SV to DIMS lenses, and a symmetrical pattern of RPR was noted in children who wore DIMS for 3 years. Myopia control using myopic defocus in the mid-periphery influenced the RPR changes and retarded myopia progression by altering the eye's growth pattern.</p
Long-term myopia control effect and safety in children wearing DIMS spectacle lenses for 6 years
This study evaluated the long-term myopia control effect and safety in children wearing Defocus Incorporated Multiple Segments (DIMS) spectacle lenses. Participants who completed the 2-year RCT were followed for a total of 6 years; their cycloplegic refractions and axial length were measured. Group 1 (n = 36) wore DIMS spectacles for 6 years; Group 2 (n = 14) wore DIMS lens for the first 3.5 years and SV spectacles afterwards; Group 3 (n = 22) wore SV spectacles in the first 2 years and switched to DIMS; Group 4 (n = 18) wore SV spectacles in the first 2 years, switched to DIMS for 1.5 years and then SV spectacles again. Group 1 showed no significant differences in myopia progression (− 0.52 ± 0.66 vs. − 0.40 ± 0.72D) and axial elongation (0.32 ± 0.26 vs. 0.28 ± 0.28 mm, both p > 0.05) between the first and the later 3 years. In the last 2.5 years, DIMS lens groups (Groups 1 and 3) had less myopia progression and axial elongation than the single vision groups (Groups 2 and 4). There was no evidence of rebound after stopping the treatment. Post-wear visual functions in all groups were within norms. The results supported that DIMS lenses provided sustained myopia control without adverse effects over the 6-year study period. Trial registration: clinicaltrials.gov; NCT02206217.</p
Going Beyond Counting First Authors in Author Co-citation Analysis
The present study examines one of the fundamental aspects of author co-citation analysis (ACA) - the way co-citation
counts are defined. Co-citation counting provides the data on which all subsequent statistical analyses and mappings
are based, and we compare ACA results based on two different types of co-citation counting - the traditional type that
only counts the first one among a cited work's authors on the one hand and a non-traditional type that takes into
account the first 5 authors of a cited work on the other hand. Results indicate that the picture produced through this non-traditional author co-citation counting contains more coherent author groups and is therefore considerably clearer. However, this picture represents fewer specialties in the research field being studied than that produced through the traditional first-author co-citation counting when the same number of top-ranked authors is selected and analyzed. Reasons for these effects are discussed
Variations on the Author
“Variations on the Author” discusses two of Eduardo Coutinho’s recent films (Um Dia na Vida, from 2010, and Últimas Conversas, posthumously released in 2015) and their contribution to the general question of documentary authorship. The director’s filmography is characterized by a consistent yet self-effacing form of authorial self-inscription: Coutinho often features as an interviewer that rather than express opinions propels discourses; an interviewer that is good at listening. This mode of self-inscription characterizes him as an author who is not expressive but who is nonetheless markedly present on the screen. In Um Dia na Vida, however, Coutinho is completely absent form the image, while Últimas Conversas, on the contrary, includes a confessional prologue that moves the director from the margins to the center of his films. This article examines the ways in which these works stand out in the filmography of a director who offers new insights into the notion of cinematic authorship
Myopia control effect of defocus incorporated multiple segments (DIMS) spectacle lens in Chinese children: results of a 3-year follow-up study
AimsTo determine myopia progression in children who continued to wear the defocus incorporated multiple segments (DIMS) lenses or switched from single vision (SV) to DIMS lenses for a 1-year period following a 2-year myopia control trial.Methods128 children participated in this study. The children who had worn DIMS lenses continued to wear DIMS lenses (DIMS group), and children who had worn SV lenses switched to wear DIMS lenses (Control-to-DIMS group). Cycloplegic spherical equivalent refraction (SER) and axial length (AL) were measured at 6-month interval. Historical controls were age matched to the DIMS group at 24 months and used for comparing the third-year changes.ResultsOver 3 years, SER and AL changes in the DIMS group (n=65) were -0.52±0.69D and 0.31±0.26 mm; these changes were not statistically significant over time (repeated measures analysis of variance, p>0.05).SER (-0.04±0. 38D) and AL (0.08±0.12 mm) changes in the Control-to-DIMS group (n=55) in the third year were less compared with the first (mean difference=0.45 ± 0.30D, 0.21±0.11 mm, pConclusionsMyopia control effect was sustained in the third year in children who had used the DIMS spectacles in the previous 2 years and was also shown in the children switching from SV to DIMS lenses
Appropriate Similarity Measures for Author Cocitation Analysis
We provide a number of new insights into the methodological discussion about author cocitation analysis. We first argue that the use of the Pearson correlation for measuring the similarity between authors’ cocitation profiles is not very satisfactory. We then discuss what kind of similarity measures may be used as an alternative to the Pearson correlation. We consider three similarity measures in particular. One is the well-known cosine. The other two similarity measures have not been used before in the bibliometric literature. Finally, we show by means of an example that our findings have a high practical relevance.information science;Pearson correlation;cosine;similarity measure;author cocitation analysis
Dispelling the Myths Behind First-author Citation Counts
We conducted a full-scale evaluative citation analysis study of scholars in the XML research field to explore just how different from each other author rankings resulting from different citation counting methods actually are, and to demonstrate the capability of emerging data and tools on the Web in supporting more realistic citation counting methods. Our results contest some common arguments for the continued
use of first-author citation counts in the evaluation of scholars, such as high correlations between author rankings by first-author citation counts and other citation
counting methods, and high costs of using more realistic citation counting methods that are not well-supported by the ISI databases. It is argued that increasingly available digital full text research papers make it possible for citation analysis studies to go beyond what the ISI databases have directly supported and to employ more
sophisticated methods
- …
