1,720,963 research outputs found

    Finite element simulation of the behavior of the periodontal ligament: A validated nonlinear contact model

    No full text
    Due to its significance in tooth movement, the stress/deformation field of periodontium and the alveolar bone remodeling process, periodontal ligament (PDL) cannot be excluded from the studies investigating dental biomechanics regarding its excessive deformability. Therefore, many analytical and numerical researches are carried out to simulate its response and to create a constitutive model via experiments intending to discover the material properties of PDL. The aim of this study is to formulate a user specified contact model that can be used in conjunction with finite element (FE) software and reflects PDL's influence on neighboring structures based on the currently available information, without requiring an actual volumetric finite element mesh of ligament. The results show good agreement with available experimental tooth mobility data. Smooth stress fields are obtained on the tooth root and alveolar bone, which is a significant aspect in bone-remodeling studies. The advantage of simulating PDL as a contact model at the interface of tooth root and the alveolar process instead of a solid-meshed FE model with poor geometric morphology and/or very dense mesh is expected to save pre/post-processing workforce, to increase the accuracy and to contribute to the smoothness of interface stress distributions

    Biomechanical comparison of oblique and step-cut osteotomies used in total hip arthroplasty with femoral shortening

    No full text
    Background Various types of shortening osteotomies and prosthesis are used for femoral reconstruction in total hip arthroplasty of the high hip dislocation. This biomechanical study investigates whether step-cut osteotomies result in better stability than oblique osteotomies and cylindrical femoral stems enhance stability of the osteotomy more than conical stems, and which osteotomy and prosthesis type maintain the stability better after cyclical loading. Methods Oblique and step-cut shortening osteotomies were compared under axial and rotational forces, using synthetic femur models and conical or cylindrical femoral prostheses. The models underwent cyclic loading for 10,000 cycles at 3 Hz (100–1000 N axial bending or 0.5–10 Nm torque). After the completion of cyclic loading, the models were loaded until failure. Stiffness values before and after cyclical loading, and failure loads were the outcome parameters. Relative displacements at the osteotomy sites were also measured using 3-Dimensions Digital Imaging Correlation System. Results The mean failure load was significantly higher in conical prosthesis groups under axial forces. In torsion tests, the mean stiffness of conical prosthesis groups after cyclical loading was higher in oblique osteotomies. The other parameters were similar between the groups. Conclusions According to the results of the study, although some individual statistically significant parameters were obtained, step-cut osteotomies, which are technically challenging procedures, were not found biomechanically superior to oblique osteotomies, with neither conical nor cylindrical prostheses

    Evaluation of strain distribution on an edentulous mandible generated by cobalt-chromium metal alloy fixed complete dentures fabricated with different techniques: An in vitro study

    No full text
    Bozdag, Ergun/0000-0001-7412-1129; SUNBULOGLU, Emin/0000-0001-9930-4618; taşın, simge/0000-0002-0483-2520; , Isil/0000-0002-3862-5781Statement of problem. Fixed complete dentures (FCDs) have been used in the treatment of completely edentulous patients for over 40 years. However, few reports have investigated misfit values and strain distribution in the context of FCDs fabricated with new technologies. Purpose. The purpose of this in vitro study was to evaluate misfit values and strain distribution in FCDs and their relation to the fabrication technique of the cobalt-chromium (Co-Cr) metal framework. Material and methods. Four implants were placed in the interforaminal region of a mandibular cast at the bone level. The Co-Cr metal alloy frameworks were fabricated using the following techniques: computer-aided design and computer-aided manufacturing (CAD-CAM), milling from hard blocks, CAD-CAM milling from soft blocks, and direct metal laser sintering (DMLS). The superstructures of equal sizes with acrylic resin bases and acrylic resin denture teeth were fabricated on the Co-Cr metal alloy framework, and a digital microscope was then used to measure the misfit between the abutments and the implants. The stress formed after the application of torque was measured with a strain-gauge stress analysis technique. Data were statistically analyzed using 1-way ANOVA and the Tukey Honestly Significant Difference test (alpha=.05). The correlation between the misfit and the strain values was evaluated with the Pearson Correlation test (alpha=.001). Results. The lowest mean misfit values (99 +/- 17 mu m) were observed in the hard block group (P<.05) and the highest in the DMLS group (139 +/- 29 mu m). A statistically significant positive relationship was found between the misfit and the stress distribution after torque application (P<.05). Moreover, the lowest misfit group, hard blocks, had the lowest mean strain values (81.1 +/- 54 MPa) after torque application. Conclusions. Within the limitations of this in vitro study, the fabrication technique used for Co-Cr metal alloy frameworks appears to influence the passive fit significantly (P<.05). The hard-block technique was found to be the most precise fabrication technique for Co-Cr metal alloy frameworks. A significant relationship was observed between the amount/distribution of misfit and the strain on the FCD (P<.05).Bezmialem Vakif University, Istanbul, Turkey [9.2015/9]This study was supported by grant no. 9.2015/9 from the Bezmialem Vakif University, Istanbul, Turkey, Research Foundation

    Going Beyond Counting First Authors in Author Co-citation Analysis

    Get PDF
    The present study examines one of the fundamental aspects of author co-citation analysis (ACA) - the way co-citation counts are defined. Co-citation counting provides the data on which all subsequent statistical analyses and mappings are based, and we compare ACA results based on two different types of co-citation counting - the traditional type that only counts the first one among a cited work's authors on the one hand and a non-traditional type that takes into account the first 5 authors of a cited work on the other hand. Results indicate that the picture produced through this non-traditional author co-citation counting contains more coherent author groups and is therefore considerably clearer. However, this picture represents fewer specialties in the research field being studied than that produced through the traditional first-author co-citation counting when the same number of top-ranked authors is selected and analyzed. Reasons for these effects are discussed

    Finite element method estimation of temperature distribution of automotive tire using one-way-coupled method

    No full text
    Numerical simulation of automotive tires is still a challenging problem due to their complex geometry and structures, as well as the non-uniform loading and operating conditions. Hysteretic loss and rolling resistance are the most crucial features of tire design for engineers. A decoupled numerical model was proposed to predict hysteretic loss and temperature distribution in a tire, however temperature dependent material properties being utilized only during the heat generation analysis stage. Cyclic change of strain energy values was extracted from 3-D deformation analysis, which was further used in a thermal analysis as input to predict temperature distribution and thermal heat generation due to hysteretic loss. This method was compared with the decoupled model where temperature dependence was ignored in both deformation and thermal analysis stages. Deformation analysis results were compared with experimental data available. The proposed method of numerical modeling was quite accurate and results were found to be close to the actual tire behavior. It was shown that one-way-coupled method provides rolling resistance and peak temperature values that are in agreement with experimental values as well

    Variations on the Author

    Get PDF
    “Variations on the Author” discusses two of Eduardo Coutinho’s recent films (Um Dia na Vida, from 2010, and Últimas Conversas, posthumously released in 2015) and their contribution to the general question of documentary authorship. The director’s filmography is characterized by a consistent yet self-effacing form of authorial self-inscription: Coutinho often features as an interviewer that rather than express opinions propels discourses; an interviewer that is good at listening. This mode of self-inscription characterizes him as an author who is not expressive but who is nonetheless markedly present on the screen. In Um Dia na Vida, however, Coutinho is completely absent form the image, while Últimas Conversas, on the contrary, includes a confessional prologue that moves the director from the margins to the center of his films. This article examines the ways in which these works stand out in the filmography of a director who offers new insights into the notion of cinematic authorship

    Appropriate Similarity Measures for Author Cocitation Analysis

    Get PDF
    We provide a number of new insights into the methodological discussion about author cocitation analysis. We first argue that the use of the Pearson correlation for measuring the similarity between authors’ cocitation profiles is not very satisfactory. We then discuss what kind of similarity measures may be used as an alternative to the Pearson correlation. We consider three similarity measures in particular. One is the well-known cosine. The other two similarity measures have not been used before in the bibliometric literature. Finally, we show by means of an example that our findings have a high practical relevance.information science;Pearson correlation;cosine;similarity measure;author cocitation analysis

    Dispelling the Myths Behind First-author Citation Counts

    Get PDF
    We conducted a full-scale evaluative citation analysis study of scholars in the XML research field to explore just how different from each other author rankings resulting from different citation counting methods actually are, and to demonstrate the capability of emerging data and tools on the Web in supporting more realistic citation counting methods. Our results contest some common arguments for the continued use of first-author citation counts in the evaluation of scholars, such as high correlations between author rankings by first-author citation counts and other citation counting methods, and high costs of using more realistic citation counting methods that are not well-supported by the ISI databases. It is argued that increasingly available digital full text research papers make it possible for citation analysis studies to go beyond what the ISI databases have directly supported and to employ more sophisticated methods

    Author Index

    No full text
    Nao informado
    corecore