1,721,131 research outputs found

    Elasto-inertial focusing and particle migration in high aspect ratio microchannels for high-throughput separation

    Full text link
    The combination of flow elasticity and inertia has emerged as a viable tool for focusing and manipulating particles using microfluidics. Although there is considerable interest in the field of elasto-inertial microfluidics owing to its potential applications, research on particle focusing has been mostly limited to low Reynolds numbers (Re<1), and particle migration toward equilibrium positions has not been extensively examined. In this work, we thoroughly studied particle focusing on the dynamic range of flow rates and particle migration using straight microchannels with a single inlet high aspect ratio. We initially explored several parameters that had an impact on particle focusing, such as the particle size, channel dimensions, concentration of viscoelastic fluid, and flow rate. Our experimental work covered a wide range of dimensionless numbers (0.05 < Reynolds number < 85, 1.5 < Weissenberg number < 3800, 5 < Elasticity number < 470) using 3, 5, 7, and 10 μm particles. Our results showed that the particle size played a dominant role, and by tuning the parameters, particle focusing could be achieved at Reynolds numbers ranging from 0.2 (1 μL/min) to 85 (250 μL/min). Furthermore, we numerically and experimentally studied particle migration and reported differential particle migration for high-resolution separations of 5 μm, 7 μm and 10 μm particles in a sheathless flow at a throughput of 150 μL/min. Our work elucidates the complex particle transport in elasto-inertial flows and has great potential for the development of high-throughput and high-resolution particle separation for biomedical and environmental applications

    Going Beyond Counting First Authors in Author Co-citation Analysis

    Full text link
    The present study examines one of the fundamental aspects of author co-citation analysis (ACA) - the way co-citation counts are defined. Co-citation counting provides the data on which all subsequent statistical analyses and mappings are based, and we compare ACA results based on two different types of co-citation counting - the traditional type that only counts the first one among a cited work's authors on the one hand and a non-traditional type that takes into account the first 5 authors of a cited work on the other hand. Results indicate that the picture produced through this non-traditional author co-citation counting contains more coherent author groups and is therefore considerably clearer. However, this picture represents fewer specialties in the research field being studied than that produced through the traditional first-author co-citation counting when the same number of top-ranked authors is selected and analyzed. Reasons for these effects are discussed

    Microfluidic bead-based methods for DNA analysis

    No full text
    With the completion of the human genome sequencing project, attention is currently shifting toward understanding how genetic variation, such as single nucleotide polymorphism (SNP), leads to disease. To identify, understand, and control biological mechanisms of living organisms, the enormous amounts of accumulated sequence information must be coupled to faster, cheaper, and more powerful technologies for DNA, RNA, and protein analysis. One approach is the miniaturization of analytical methods through the application of microfluidics, which involves the manipulation of fluids in micrometer-sized channels. Advances in microfluidic chip technology are expected to play a major role in the development of cost-effective and rapid DNA analysis methods. This thesis presents microfluidic approaches for different DNA genotyping assays. The overall goal is to combine the potential of the microfluidic lab-on-a-chip concept with biochemistry to develop and improve current methods for SNP genotyping. Three genotyping assays using miniaturized microfluidic approaches are addressed. The first two assays are based on primer extension by DNA polymerase. A microfluidic device consisting of a flow-through filter chamber for handling beads with nanoliter liquid volumes was used in these studies. The first assay involved an allelespecific extension strategy. The microfluidic approach took advantage of the different reaction kinetics of matched and mismatched configurations at the 3’-ends of a primer/template complex. The second assay consisted of adapting pyrosequencing technology, a bioluminometric DNA sequencing assay based on sequencing-bysynthesis, to a microfluidic flow-through platform. Base-by-base sequencing was performed in a microfluidic device to obtain accurate SNP scoring data on nanoliter volumes. This thesis also presents the applications of monolayer of beads immobilized by microcontact printing for chip-based DNA analysis. Single-base incorporation could be detected with pyrosequencing chemistry on these monolayers. The third assay developed is based on a hybridization technology termed Dynamic Allele-Specific Hybridization (DASH). In this approach, monolayered beads containing DNA duplexes were randomly immobilized on the surface of a microheater chip. DNA melting-curve analysis was performed by dynamically heating the chip while simultaneously monitoring the DNA denaturation profile to determine the genotype. Multiplexing based on single-bead analysis was achieved at heating rates more than 20 times faster than conventional DASH provides.QC 20101008</p

    Variations on the Author

    Full text link
    “Variations on the Author” discusses two of Eduardo Coutinho’s recent films (Um Dia na Vida, from 2010, and Últimas Conversas, posthumously released in 2015) and their contribution to the general question of documentary authorship. The director’s filmography is characterized by a consistent yet self-effacing form of authorial self-inscription: Coutinho often features as an interviewer that rather than express opinions propels discourses; an interviewer that is good at listening. This mode of self-inscription characterizes him as an author who is not expressive but who is nonetheless markedly present on the screen. In Um Dia na Vida, however, Coutinho is completely absent form the image, while Últimas Conversas, on the contrary, includes a confessional prologue that moves the director from the margins to the center of his films. This article examines the ways in which these works stand out in the filmography of a director who offers new insights into the notion of cinematic authorship

    Appropriate Similarity Measures for Author Cocitation Analysis

    Full text link
    We provide a number of new insights into the methodological discussion about author cocitation analysis. We first argue that the use of the Pearson correlation for measuring the similarity between authors’ cocitation profiles is not very satisfactory. We then discuss what kind of similarity measures may be used as an alternative to the Pearson correlation. We consider three similarity measures in particular. One is the well-known cosine. The other two similarity measures have not been used before in the bibliometric literature. Finally, we show by means of an example that our findings have a high practical relevance.information science;Pearson correlation;cosine;similarity measure;author cocitation analysis

    Dispelling the Myths Behind First-author Citation Counts

    Full text link
    We conducted a full-scale evaluative citation analysis study of scholars in the XML research field to explore just how different from each other author rankings resulting from different citation counting methods actually are, and to demonstrate the capability of emerging data and tools on the Web in supporting more realistic citation counting methods. Our results contest some common arguments for the continued use of first-author citation counts in the evaluation of scholars, such as high correlations between author rankings by first-author citation counts and other citation counting methods, and high costs of using more realistic citation counting methods that are not well-supported by the ISI databases. It is argued that increasingly available digital full text research papers make it possible for citation analysis studies to go beyond what the ISI databases have directly supported and to employ more sophisticated methods

    Author Index

    No full text
    Nao informado

    MicroCAP

    No full text
    </p

    koamabayili/VECTRON-author-checklist: VECTRON author checklist

    No full text
    We have done our best to complete the author checklist relating to the use of animals in the hut study. Note that the objective for the hut study was to evaluate the IRS treatment applications for residual efficacy against Anopheles mosquitoes, including the local An. coluzzii mosquito population. Cows were only used to attract mosquitoes into the huts and no tests were carried out directly on the cows. The author checklist is intended for use with studies where experiments are carried out on animals, which is why we have had such difficulty in completing this for the hut study, as many of the questions do not relate to how the cows were used
    corecore