1,739 research outputs found
RIC-HSCT for MF/SS
Advanced-stage mycosis fungoides and Sezary syndrome (MF/SS) have a poor prognosis. Allogeneic hematopoietic stem cell transplantation (HSCT), particularly using a reduced-intensity conditioning (RIC) regimen, is a promising treatment for advanced-stage MF/SS. We performed RIC-HSCT in nine patients with advanced MF/SS. With a median follow-up period of 954days after HSCT, the estimated 3-year overall survival was 85.7% (95% confidence interval, 33.4-97.9%) with no non-relapse mortality. Five patients relapsed after RIC-HSCT; however, in four patients whose relapse was detected only from the skin, persistent complete response was achieved in one patient, and the disease was manageable in other three patients by the tapering of immunosuppressants and donor lymphocyte infusion, suggesting that graft-versus-lymphoma effect and "down-staging" effect from advanced stage to early stage by HSCT improve the prognosis of advanced-stage MF/SS. These results suggest that RIC-HSCT is an effective treatment for advanced MF/SS
Preparation of mono-sized epoxy/MF microcapsulesin the appearance of polyvinyl alcohol as co-emulsifier
For epoxy microcapsules embedded in concrete as mechanic-triggered self-healing adhesive, globular shape with uniform size is the basic requirement to ensure the solid shell broken and the liquid core released at a designed stress. In this paper, monodispersed melamine\u96formaldehyde (MF) resin-walled epoxy E-51 microcapsules were successfully fabricated in an in situ polycondensation process, in which a certain amount of polyvinyl alcohol (PVA) solution was added as coemulsifier to control the microcapsules\u92 shape and size. Detail investigation shows, with the cooperation of PVA, the microcapsule morphologies and size distribution were ease to be adjusted by the parameters such as emulsifying agents, agitation rate, pH value and acidification time
ACT Family Violence Intervention Program review
This paper reports on a review of the Australian Capital Territory’s Family Violence Intervention Program, which provides an interagency response to family violence matters.
The scope of the review was to analyse the program’s activities and outcomes using 2007–08 data provided by participating agencies, supported by in-depth interviews with key stakeholders including victims whose matters had been finalised in court. After the completion of this report, additional data from 2008–09 and 2009–10 was made available by some Family Violence Intervention Program (FVIP) participating agencies. Although not within the scope of this evaluation, these data pointed to some preliminary improvements in the FVIP
Hepatitis C virus p7 protein is crucial for assembly and release of infectious virions
Hepatitis C virus (HCV) infection is associated with chronic liver disease and currently affects about 3% of the world population. Although much has been learned about the function of individual viral proteins, the role of the HCV p7 protein in virus replication is not known. Recent data, however, suggest that it forms ion channels that may be targeted by antiviral compounds. Moreover, this protein was shown to be essential for infectivity in chimpanzee. Employing the novel HCV infection system and using a genetic approach to investigate the function of p7 in the viral replication cycle, we find that this protein is essential for efficient assembly and release of infectious virions across divergent virus strains. We show that p7 promotes virus particle production in a genotype-specific manner most likely due to interactions with other viral factors. Virus entry, on the other hand, is largely independent of p7, as the specific infectivity of released virions with a defect in p7 was not affected. Together, these observations indicate that p7 is primarily involved in the late phase of the HCV replication cycle. Finally, we note that p7 variants from different isolates deviate substantially in their capacity to promote virus production, suggesting that p7 is an important virulence factor that may modulate fitness and in turn virus persistence and pathogenesis
NF membrane fouling by aluminum and iron coagulant residuals after coagulation-MF pretreatment
The effects of coagulant residuals on fouling of a nanofiltration (NF) membrane were investigated. Experiments were carried out with a laboratory-scale microfiltration (MF)-NF setup and a pilot MF-NF plant. In the laboratory-scale experiments, NF feed water was pretreated with poly-aluminum chloride (PACl) or alum followed by MF. NF membrane permeability declined when the feed water contained residual aluminum at 18 μg/L or more, but not when it was lower than 9 μg/L. When pretreated with ferric chloride, no substantial decline of NF membrane permeability was observed: residual iron did not affect the permeability. When SiO2 was added to the water before the pretreatment with PACl, the NF membrane permeability declined at about double the speed. Thermodynamic calculations and elemental analysis of foulants recovered from the membranes indicated that the majority of inorganic foulants were compounds composed of aluminum, silicate, and possibly potassium. In the pilot plant, NF feed was pretreated by PACl. Transmembrane pressure for NF doubled over 4.5 months of operation. Although the aluminum concentration in the NF feed was not high (30 μg/L), analysis of membrane foulants revealed excessive accumulation of aluminum and silicate, also suggesting that aluminum residuals caused the membrane fouling by alumino-silicates or aluminum hydroxide
The Incidence and Clinical Relevance of Graft Hypertrophy After Matrix-Based Autologous Chondrocyte Implantation
Background: Graft hypertrophy is the most common complication of periosteal autologous chondrocyte implantation (p-ACI).
Purpose: The aim of this prospective study was to analyze the development, the incidence rate, and the persistence of graft hypertrophy after matrix-based autologous chondrocyte implantation (mb-ACI) in the knee joint within a 2-year postoperative course.
Study Design: Case series; Level of evidence, 4.
Methods: Between 2004 and 2007, a total of 41 patients with 44 isolated cartilage defects of the knee were treated with the mb-ACI technique. The mean age of the patients was 35.8 years (standard deviation [SD], 11.3 years), and the mean body mass index was 25.9 (SD, 4.2; range, 19-35.3). The cartilage defects were arthroscopically classified as Outerbridge grades III and IV. The mean area of the cartilage defect measured 6.14 cm2 (SD, 2.3 cm2). Postoperative clinical and magnetic resonance imaging (MRI) examinations were conducted at 3, 6, 12, and 24 months to analyze the incidence and course of the graft.
Results: Graft hypertrophy developed in 25% of the patients treated with mb-ACI within a postoperative course of 1 year; 16% of the patients developed hypertrophy grade 2, and 9% developed hypertrophy grade 1. Graft hypertrophy occurred primarily in the first 12 months and regressed in most cases within 2 years. The International Knee Documentation Committee (IKDC) and visual analog scale (VAS) scores improved during the postoperative follow-up time of 2 years. There was no difference between the clinical results regarding the IKDC and VAS pain scores and the presence of graft hypertrophy.
Conclusion: The mb-ACI technique does not lead to graft hypertrophy requiring treatment as opposed to classic p-ACI. The frequency of occurrence of graft hypertrophy after p-ACI and mb-ACI is comparable. Graft hypertrophy can be considered as a temporary excessive growth of regenerative cartilage tissue rather than a true graft hypertrophy. It is therefore usually not a persistent or systematic complication in the treatment of circumscribed cartilage defects with mb-ACI
Correction Factor on Dynamic Force in a Marsh Funnel Test for Tunneling
This paper presents an improvement on a previous model for predicting the Marsh funnel (MF) test that is used in slurry shield tunneling for evaluating the rheological properties of bentonite slurries. The improvement focuses on the prediction of the dynamic part for fluids with small MF times. The velocity profile of the Herschel-Bulkley fluid in a laminar pipe flow condition is first investigated and a correction factor is introduced in the improved model. Comparisons of results from experiments and calculations with the previous model confirm the improved performance over the existing model. The rheological parameters obtained from the improved model show good resemblance to those obtained from a laboratory viscometer. The work also provides a reference to similar applications such as fluid transportation through pipelines where dynamic pressure dominates and therefore should be correctly predicted considering its velocity profile in a laminar condition.Green Open Access added to TU Delft Institutional Repository 'You share, we take care!' - Taverne project https://www.openaccess.nl/en/you-share-we-take-care Otherwise as indicated in the copyright section: the publisher is the copyright holder of this work and the author uses the Dutch legislation to make this work public.Offshore and Dredging Engineerin
Thermal analysis of a miniature magnetic fluid seal installed in an implantable rotary pump
The capacity of a magnetic fluid (MF) seal is decreased by increased MF temperature. A cooling system for MF is limited in a miniature MF seal installed in an implantable rotary pump. MF temperature in an MF seal installed in an implantable rotary pump was studied. The temperature of MF in a rotary pump was measured in vitro. Also, steady-state thermal analyses were conducted for an implantable rotary pump model. The results showed that (1) the decrease in magnetization of an MF due to increased temperature is negligible when the heat transfer coefficient of the seal housing is greater than 500 W/(m2·K) and (2) the increased temperature is mainly due to heat flux from the motor, and the magnitude of temperature increase due to viscous friction in the MF is low. In conclusion, an MF seal can be used in an implantable rotary pump from the standpoint of heat characteristics
Adaptation of hepatitis C virus to mouse CD81 permits infection of mouse cells in the absence of human entry factors
Hepatitis C virus (HCV) naturally infects only humans and chimpanzees. The determinants responsible for this narrow species tropism are not well defined. Virus cell entry involves human scavenger receptor class B type I (SR-BI), CD81, claudin-1 and occludin. Among these, at least CD81 and occludin are utilized in a highly species-specific fashion, thus contributing to the narrow host range of HCV. We adapted HCV to mouse CD81 and identified three envelope glycoprotein mutations which together enhance infection of cells with mouse or other rodent receptors approximately 100-fold. These mutations enhanced interaction with human CD81 and increased exposure of the binding site for CD81 on the surface of virus particles. These changes were accompanied by augmented susceptibility of adapted HCV to neutralization by E2-specific antibodies indicative of major conformational changes of virus-resident E1/E2-complexes. Neutralization with CD81, SR-BI- and claudin-1-specific antibodies and knock down of occludin expression by siRNAs indicate that the adapted virus remains dependent on these host factors but apparently utilizes CD81, SR-BI and occludin with increased efficiency. Importantly, adapted E1/E2 complexes mediate HCV cell entry into mouse cells in the absence of human entry factors. These results further our knowledge of HCV receptor interactions and indicate that three glycoprotein mutations are sufficient to overcome the species-specific restriction of HCV cell entry into mouse cells. Moreover, these findings should contribute to the development of an immunocompetent small animal model fully permissive to HCV
Magnetic fluid seals working in liquid environments: Factors limiting their life and solution methods
A magnetic fluid (MF) seal enables mechanical contact-free rotation of a shaft and hence has excellent durability. The performance of an MF seal, however, decreases in liquids. Factors limiting seal life are MF flowing away and mixing of MF with liquids. We developed an MF seal that had a "shield'' mechanism. Two types of shield were placed in MF seals installed in rotary pumps. Long-term durability tests were conducted. The MF seal with a shield having a small cavity space showed a longer life (207+ days), while the MF seal with a shield having a large cavity space failed after 28, 32 and 31 days. When a rotary pump is connected to an afterload, water flows into the cavity space of the shield through a concentric annulus and compresses air in the cavity. The water flow stops once the air pressure equilibrates the afterload pressure. Water remained in the entrance annulus and did not make contact with the MF in the case of the shield having a small cavity space, while water entered the cavity space and made contact with the MF in the case of the shield having a large cavity space. Less water in contact with the MF prolonged the seal life. In conclusion, the use of an optimally designed shield prolongs an MF seal life by preventing the MF from flowing away and mixing with liquids
- …
