1,721,117 research outputs found
Multi-center transferability of a breath-hold T2 technique for myocardial iron assessment.
Background: Cardiac iron overload is the leading cause of death in thalassemia major and is usually assessed using myocardial T2* measurements. Recently a cardiovascular magnetic resonance (CMR) breath-hold T2 sequence has been developed as a possible alternative. This cardiac T2 technique has good interstudy reproducibility, but its transferability to different centres has not yet been investigated.
Methods and Results: The breath-hold black blood spin echo T2 sequence was installed and validated on 1.5T Siemens MR scanners at 4 different centres across the world. Using this
sequence, 5–10 thalassemia patients from each centre were scanned twice locally within a week for local interstudy reproducibility (n = 34) and all were rescanned within one month at the standardization centre in London (intersite reproducibility). The local interstudy reproducibility
(coefficient of variance) and mean difference were 4.4% and -0.06 ms. The intersite reproducibility and mean difference between scanners were 5.2% and -0.07 ms.
Conclusion: The breath-hold myocardial T2 technique is transferable between Siemens scanners with good intersite and local interstudy reproducibility. This technique may have value in the diagnosis and management of patients with iron overload conditions such as thalassemia
Right ventricular volumes and function in thalassemia major patients in the absence of myocardial iron overload
Aim: We aimed to define reference ranges for right ventricular (RV) volumes, ejection fraction (EF) in thalassemia major patients (TM) without myocardial iron overload.Methods and results: RV volumes, EF and mass were measured in 80 TM patients who had no myocardial iron overload (myocardial T2* > 20 ms by cardiovascular magnetic resonance). All patients were receiving deferoxamine chelation and none had evidence of pulmonary hypertension or other cardiovascular comorbidity. Forty age and sex matched healthy non-anemic volunteers acted as controls. The mean RV EF was higher in TM patients than controls (males 66.2 +/- 4.1% vs 61.6 +/- 6%, p = 0.0009; females 66.3 +/- 5.1% vs 62.6 +/- 6.4%, p = 0.017), which yielded a raised lower threshold of normality for RV EF in TM patients (males 58.0% vs 50.0% and females 56.4% vs 50.1%). RV end-diastolic volume index was higher in male TM patients (mean 98.1 +/- 17.3 mL vs 88.4 +/- 11.2 mL/m(2), p = 0.027), with a higher upper limit (132 vs 110 mL/m(2)) but this difference was of borderline significance for females (mean 86.5 +/- 13.6 mL vs 80.3 +/- 12.8 mL/m(2), p = 0.09, with upper limit of 113 vs 105 mL/m(2)). The cardiac index was raised in TM patients (males 4.8 +/- 1.0 L/min vs 3.4 +/- 0.7 L/min, p < 0.0001; females 4.5 +/- 0.8 L/min vs 3.2 +/- 0.8 L/min, p < 0.0001). No differences in RV mass index were identified.Conclusion: The normal ranges for functional RV parameters in TM patients with no evidence of myocardial iron overload differ from healthy non-anemic controls. The new reference RV ranges are important for determining the functional effects of myocardial iron overload in TM patients
Value of black blood T2*cardiovascular magnetic resonance.
Purpose
To assess whether black blood T2* cardiovascular magnetic resonance is superior to conventional white blood imaging of cardiac iron in patients with thalassaemia major (TM).
Materials and methods
We performed both conventional white blood and black blood T2* CMR sequences in 100 TM patients to determine intra and inter-observer variability and presence of artefacts. In 23 patients, 2 separate studies of both techniques were performed to assess interstudy reproducibility.
Results
Cardiac T2* values ranged from 4.5 to 43.8 ms. The mean T2* values were not different between black blood and white blood acquisitions (20.5 vs 21.6 ms, p = 0.26). Compared with the conventional white blood diastolic acquisition, the coefficient of variance of the black blood CMR technique was superior for intra-observer reproducibility (1.47% vs 4.23%, p < 0.001), inter-observer reproducibility (2.54% vs 4.50%, p < 0.001) and inter-study reproducibility (4.07% vs 8.42%, p = 0.001). Assessment of artefacts showed a superior score for black blood vs white blood scans (4.57 vs 4.25; p < 0.001).
Conclusions
Black blood T2* CMR has superior reproducibility and reduced imaging artefacts for the assessment of cardiac iron, in comparison with the conventional white blood technique, which make it the preferred technique for clinical practice
Myocardial pre-synaptic sympathetic function correlates with glucose uptake in the failing human heart
PURPOSE:
We have previously shown that the myocardium of patients with heart failure (HF) is insulin resistant. Chronic beta-adrenergic stimulation has been implicated in insulin resistance in cultured cardiomyocytes in vitro, where sustained noradrenaline stimulation inhibited insulin-modulated glucose uptake. As the failing heart is characterized by increased sympathetic drive, we hypothesized that there is a correlation between pre-synaptic sympathetic function and insulin sensitivity in the myocardium of patients with HF.
METHODS:
Eight patients (aged 67 +/- 7 years) with coronary artery disease and left ventricular dysfunction (ejection fraction 44 +/- 10%) underwent function and viability assessment with cardiovascular magnetic resonance. Myocardial glucose utilization (MGU) was measured using positron emission tomography (PET) with (18)F-fluorodeoxyglucose (FDG). Pre-synaptic noradrenaline re-uptake was measured by calculating [(11)C]meta-hydroxy-ephedrine (HED) volume of distribution (V (d)) with PET. Two groups of healthy volunteers served as controls for the FDG (n = 8, aged 52 +/- 4 years, p < 0.01 vs patients) and HED (n = 8, aged 40 +/- 6 years, p < 0.01 vs patients) data.
RESULTS:
MGU in patients was reduced in both normal remote (0.44 +/- 0.14 micromol.min(-1).g(-1)) and dysfunctional (0.49 +/- 0.14 micromol.min(-1).g(-1)) segments compared with controls (0.61 +/- 0.7 micromol.min(-1).g(-1); p < 0.001 vs both). HED V (d) was reduced in dysfunctional segments of patients (38.9 +/- 21.2 ml.g(-1)) compared with normal segments (52.2 +/- 19.6 ml.g(-1)) and compared with controls (62.7 +/- 11.3 ml.g(-1)). In patients, regional MGU was correlated with HED V (d).
CONCLUSION:
The results of this study provide novel evidence of a correlation between cardiac sympathetic function and insulin sensitivity, which may represent one of the mechanisms contributing to insulin resistance in failing human hearts
Pre- and post-synaptic sympathetic function in human hibernating myocardium
PURPOSE:
Impaired pre-synaptic noradrenaline uptake-1 mechanism has been reported in a swine model of hibernating myocardium (HM). To ascertain whether adrenergic neuroeffector abnormalities are present in human HM, we combined functional measurements in vivo using cardiovascular magnetic resonance (CMR) and positron emission tomography (PET) to assess pre- and post-synaptic sympathetic function.
METHODS:
Twelve patients with coronary artery disease and chronic left ventricular (LV) dysfunction underwent CMR at baseline and 6 months after bypass for assessment of regional and global LV function and identification of segments with reversible dysfunction. Before surgery, myocardial noradrenaline uptake-1 ([(11)C]meta-hydroxy-ephedrine; HED) and beta-adrenoceptor (beta-AR) density ([(11)C]CGP-12177) were measured with PET. Patient PET data were compared with those in 18 healthy controls.
RESULTS:
The volume of distribution (V(d)) of HED in HM (47.95+/-28.05 ml/g) and infarcted myocardium (42.69+/-25.76 ml/g) was significantly reduced compared with controls (66.09+/-14.48 ml/g). The V(d) of HED in normal myocardium (49.93+/-20.48 ml/g) of patients was also lower than that in controls and the difference was close to statistical significance (p=0.06). Myocardial beta-AR density was significantly lower in HM (5.49+/-2.35 pmol/g), infarcted (4.82+/-2.61 pmol/g) and normal (5.86+/-1.81 pmol/g) segments of patients compared with healthy controls (8.61+/-1.32 pmol/g).
CONCLUSION:
Noradrenaline uptake-1 mechanism and beta-AR density are reduced in the myocardium of patients with chronic LV dysfunction and evidence of HM. The increased sympathetic activity to the heart in these patients is a generalised rather than regional phenomenon which is likely to contribute to the remodelling process of the whole LV rather than playing a causative role in HM
Troponin release following endurance exercise: is inflammation the cause? a cardiovascular magnetic resonance study
Background: The aetiology and clinical significance of troponin release following endurance exercise is unclear but may be due to transient myocardial inflammation. Cardiovascular magnetic resonance (CMR) affords us the opportunity to evaluate the presence of myocardial inflammation and focal fibrosis and is the ideal imaging modality to study this hypothesis. We sought to correlate the relationship between acute bouts of ultra endurance exercise leading to cardiac biomarkers elevation and the presence of myocardial inflammation and fibrosis using CMR.Methods: 17 recreation athletes (33.5 +/- 6.5 years) were studied before and after a marathon run with troponin, NTproBNP, and CMR. Specific imaging parameters to look for inflammation included T2 weighted images, and T1 weighted spin-echo images before and after an intravenous gadolinium-DTPA to detect myocardial hyperemia secondary to inflammation. Late gadolinium imaging was performed (LGE) to detect any focal regions of replacement fibrosis.Results: Eleven of the 17 participant had elevations of TnI above levels of cut off for myocardial infarction 6 hrs after the marathon (0.075 +/- 0.02, p = 0.007). Left ventricular volumes were reduced post marathon and a small increase in ejection fraction was noted (64 +/- 1% pre, 67 +/- 1.2% post, P = 0.014). Right ventricular volumes, stroke volume, and ejection fraction were unchanged post marathon. No athlete fulfilled criteria for myocardial inflammation based on current criteria. No regions of focal fibrosis were seen in any of the participants.Conclusion: Exercise induced cardiac biomarker release is not associated with any functional changes by CMR or any detectable myocardial inflammation or fibrosis
Going Beyond Counting First Authors in Author Co-citation Analysis
The present study examines one of the fundamental aspects of author co-citation analysis (ACA) - the way co-citation
counts are defined. Co-citation counting provides the data on which all subsequent statistical analyses and mappings
are based, and we compare ACA results based on two different types of co-citation counting - the traditional type that
only counts the first one among a cited work's authors on the one hand and a non-traditional type that takes into
account the first 5 authors of a cited work on the other hand. Results indicate that the picture produced through this non-traditional author co-citation counting contains more coherent author groups and is therefore considerably clearer. However, this picture represents fewer specialties in the research field being studied than that produced through the traditional first-author co-citation counting when the same number of top-ranked authors is selected and analyzed. Reasons for these effects are discussed
Variations on the Author
“Variations on the Author” discusses two of Eduardo Coutinho’s recent films (Um Dia na Vida, from 2010, and Últimas Conversas, posthumously released in 2015) and their contribution to the general question of documentary authorship. The director’s filmography is characterized by a consistent yet self-effacing form of authorial self-inscription: Coutinho often features as an interviewer that rather than express opinions propels discourses; an interviewer that is good at listening. This mode of self-inscription characterizes him as an author who is not expressive but who is nonetheless markedly present on the screen. In Um Dia na Vida, however, Coutinho is completely absent form the image, while Últimas Conversas, on the contrary, includes a confessional prologue that moves the director from the margins to the center of his films. This article examines the ways in which these works stand out in the filmography of a director who offers new insights into the notion of cinematic authorship
Appropriate Similarity Measures for Author Cocitation Analysis
We provide a number of new insights into the methodological discussion about author cocitation analysis. We first argue that the use of the Pearson correlation for measuring the similarity between authors’ cocitation profiles is not very satisfactory. We then discuss what kind of similarity measures may be used as an alternative to the Pearson correlation. We consider three similarity measures in particular. One is the well-known cosine. The other two similarity measures have not been used before in the bibliometric literature. Finally, we show by means of an example that our findings have a high practical relevance.information science;Pearson correlation;cosine;similarity measure;author cocitation analysis
- …
