External ring fixators: an overview.
External fixation is widely used in the fixation of fractures and limb deformities. The mechanical characteristics of a specific external fixator are major factors in determining the biomechanical environment at a fracture/osteotomy site and, hence, affect the healing process. Although the optimal biomechanical environment for healing of a fracture or an osteotomy is unknown, a specific range of interfragmentary motion exists which promotes healing. It is therefore desirable that the mechanics of an external fixator can be manipulated to enable the surgeon to control the range of interfragmentary motion. The characteristics of an external fixator are defined by a large number of variables. Therefore, to gain control over the degree of interfragmentary motion, an understanding of the effect of each variable and how it interacts with the others to determine the overall characteristics of the device is required. For the past two decades, individual components and whole-frame configurations have been studied in depth. This article provides a summary of previous work concerning the mechanics of external ring fixators and how they affect the biomechanical environment at the fracture/osteotomy site
The effect of clamping a tensioned wire: implications for the Ilizarov external fixation system.
This study demonstrates that clamping a tensioned wire can cause a reduction in wire tension. Tension (about 1275 N) was applied to a wire that was subsequently clamped, using cannulated bolts, to the steel half-ring of an Ilizarov external fixator. The tension in the wire was monitored before, during and after clamping. The apparatus was disassembled and the deformations in the wire caused by the clamps were measured. This experiment was repeated 15 times. When the wire was clamped to the frame, the wire tension was reduced by 22 +/- 7 per cent (mean +/- standard deviation, SD). The drop in wire tension was linearly correlated (r = 0.96; p < 0.001) with the deformation caused by the bolts. A finite element (FE) model of the wire was also constructed. The model was pre-stressed (tensioned), and the clamping effect replicated. This analysis showed that clamping the wire could be considered to squeeze the wire outwards (like toothpaste from a tube) and so reduce its tension during fixator assembly. To assess the magnitude of this effect in the clinical situation, the FE model analysis was repeated to replicate clamping a 1.8-mm-diameter wire to a 180-mm-diameter steel Ilizarov ring component. The analysis showed that for these conditions the tension reduced by 8-29 per cent. The results of this study highlight a general engineering problem: how can a tensioned wire be secured to a structure without an appreciable loss of tension? If the performance of the structure depends on the wire tension, this performance will change when the wire is secured
Finite element modelling of the Ilizarov external fixation system.
This study describes a computational method for predicting the mechanical response of any configuration of the Ilizarov external fixation system. Mechanical testing of each of the individual components (ring, threaded rod, and wire) of the Ilizarov system was used to determine the stiffness of each component. Finite element (FE) analysis was then used to model each of the individual components. Each model was tuned to match the mechanical testing. A modular FE modelling system, using a master input file, was then developed where the tuned FE models of the individual components could be generated, positioned, and interconnected to replicate a range of fixator configurations. The results showed that the stiffness predications from the FE modelling of the fixator configurations were consistently 10 per cent higher than the stiffness values obtained from the mechanical testing. The FE modelling system can be used to predict the characteristic response of the fixator configurations and clearly shows the relative changes in that response for variations in the number of components used
Wire tension in the Ilizarov system: accuracy of the wire-tensioning device.
The Ilizarov fixator consists of tensioned wires that attach bone segments to a modular frame. The aim of this study was to establish the accuracy and precision of the wire-tensioning device supplied with the Ilizarov external fixation system. The device was used to tension a wire in direct opposition to a calibrated load cell. Five subjects tested three devices, at each of their four tension settings, in two separate sessions. Subjects could not see the true tension during the test. There were significant differences between the results for different subjects (p < 0.01) and instruments (p < 0.01) but not for different tension settings or between the two sessions. Overall mean measured tensions were 4.9 per cent (standard deviation, 4.4 per cent) below intended values. Tensions obtained at the maximum edge (completely occluded) on the scale markings were significantly (p < 0.001) closer to the nominal values (mean discrepancy, 3.6 per cent) than those at the minimum edge (mean discrepancy, 17.6 per cent). Several factors influence wire tension. Tensioning devices are not identical and the results obtained with them depend on the user. If the scale markings are completely occluded, the discrepancy between intended and actual tensions of around 5 per cent is likely to be adequate for clinical practice since surgeons do not select the most suitable tension following quantitative data assessment, but rather it is a judgement based on surgical experience and consideration for the patient weight and expected level of activity
Going Beyond Counting First Authors in Author Co-citation Analysis
The present study examines one of the fundamental aspects of author co-citation analysis (ACA) - the way co-citation
counts are defined. Co-citation counting provides the data on which all subsequent statistical analyses and mappings
are based, and we compare ACA results based on two different types of co-citation counting - the traditional type that
only counts the first one among a cited work's authors on the one hand and a non-traditional type that takes into
account the first 5 authors of a cited work on the other hand. Results indicate that the picture produced through this non-traditional author co-citation counting contains more coherent author groups and is therefore considerably clearer. However, this picture represents fewer specialties in the research field being studied than that produced through the traditional first-author co-citation counting when the same number of top-ranked authors is selected and analyzed. Reasons for these effects are discussed
Variations on the Author
“Variations on the Author” discusses two of Eduardo Coutinho’s recent films (Um Dia na Vida, from 2010, and Últimas Conversas, posthumously released in 2015) and their contribution to the general question of documentary authorship. The director’s filmography is characterized by a consistent yet self-effacing form of authorial self-inscription: Coutinho often features as an interviewer that rather than express opinions propels discourses; an interviewer that is good at listening. This mode of self-inscription characterizes him as an author who is not expressive but who is nonetheless markedly present on the screen. In Um Dia na Vida, however, Coutinho is completely absent form the image, while Últimas Conversas, on the contrary, includes a confessional prologue that moves the director from the margins to the center of his films. This article examines the ways in which these works stand out in the filmography of a director who offers new insights into the notion of cinematic authorship
Appropriate Similarity Measures for Author Cocitation Analysis
We provide a number of new insights into the methodological discussion about author cocitation analysis. We first argue that the use of the Pearson correlation for measuring the similarity between authors’ cocitation profiles is not very satisfactory. We then discuss what kind of similarity measures may be used as an alternative to the Pearson correlation. We consider three similarity measures in particular. One is the well-known cosine. The other two similarity measures have not been used before in the bibliometric literature. Finally, we show by means of an example that our findings have a high practical relevance.information science;Pearson correlation;cosine;similarity measure;author cocitation analysis
Dispelling the Myths Behind First-author Citation Counts
We conducted a full-scale evaluative citation analysis study of scholars in the XML research field to explore just how different from each other author rankings resulting from different citation counting methods actually are, and to demonstrate the capability of emerging data and tools on the Web in supporting more realistic citation counting methods. Our results contest some common arguments for the continued
use of first-author citation counts in the evaluation of scholars, such as high correlations between author rankings by first-author citation counts and other citation
counting methods, and high costs of using more realistic citation counting methods that are not well-supported by the ISI databases. It is argued that increasingly available digital full text research papers make it possible for citation analysis studies to go beyond what the ISI databases have directly supported and to employ more
sophisticated methods
- …