1,720,958 research outputs found

    Ti metal electrode as an unconventional amperometric sensor for determination of Au(III) species

    No full text
    The control of the noble metal concentration is crucial in order to increase the efficiency of hydrometallurgic processes in mining and in the recovery of precious materials from electronic waste. The present study is devoted to the development of an effective procedure for the quantification of Au(III) species dissolved in aqueous solutions, similar real complex matrices included. In particular, a novel electrode system based on Ti has been studied. This electrode material is still poorly investigated in the framework of electroanalysis, despite its lack of sensitivity to common interfering species, such as oxygen; hence, the determination of metal species can be carried out without performing deaeration of the solution. In addition, the interfering effect due to the presence of other heavy metal ions, such as Ag, Fe and Pb, has been minimised by a proper choice of the conditions adopted for the amperometric measurements. Ti electrodes exhibit reproducible electrochemical responses, even in the presence of high concentration of organic fouling species typical of biosorption processes

    Development of a redox polymer based on poly(2-hydroxyethyl methacrylate)for disposable amperometric sensors

    Full text link
    Membranes based on poly(2-hydroxyethyl methacrylate), chemically modified with ferrocene functionalities, are proposed as novel coatings for the development of disposable amperometric sensors. They are mass-produced on an inert support through an UV photo-induced polymerization, forming self-standing films that can be transferred on an electrode surface. Thanks to the characteristic of the functionalized methacrylate matrix to rapidly and reversibly swell by incorporation of large amounts of water, the ferrocene moieties are in intimate contact with the electrolytic solution. They can activate effective electrocatalytic processes that can be exploited in the field of amperometric sensing. The performance of the methacrylate coating with respect to the determination of hydroquinone benchmark analyte has been tested both in a static solution and in a flux cell

    Going Beyond Counting First Authors in Author Co-citation Analysis

    Full text link
    The present study examines one of the fundamental aspects of author co-citation analysis (ACA) - the way co-citation counts are defined. Co-citation counting provides the data on which all subsequent statistical analyses and mappings are based, and we compare ACA results based on two different types of co-citation counting - the traditional type that only counts the first one among a cited work's authors on the one hand and a non-traditional type that takes into account the first 5 authors of a cited work on the other hand. Results indicate that the picture produced through this non-traditional author co-citation counting contains more coherent author groups and is therefore considerably clearer. However, this picture represents fewer specialties in the research field being studied than that produced through the traditional first-author co-citation counting when the same number of top-ranked authors is selected and analyzed. Reasons for these effects are discussed

    Variations on the Author

    Full text link
    “Variations on the Author” discusses two of Eduardo Coutinho’s recent films (Um Dia na Vida, from 2010, and Últimas Conversas, posthumously released in 2015) and their contribution to the general question of documentary authorship. The director’s filmography is characterized by a consistent yet self-effacing form of authorial self-inscription: Coutinho often features as an interviewer that rather than express opinions propels discourses; an interviewer that is good at listening. This mode of self-inscription characterizes him as an author who is not expressive but who is nonetheless markedly present on the screen. In Um Dia na Vida, however, Coutinho is completely absent form the image, while Últimas Conversas, on the contrary, includes a confessional prologue that moves the director from the margins to the center of his films. This article examines the ways in which these works stand out in the filmography of a director who offers new insights into the notion of cinematic authorship

    Appropriate Similarity Measures for Author Cocitation Analysis

    Full text link
    We provide a number of new insights into the methodological discussion about author cocitation analysis. We first argue that the use of the Pearson correlation for measuring the similarity between authors’ cocitation profiles is not very satisfactory. We then discuss what kind of similarity measures may be used as an alternative to the Pearson correlation. We consider three similarity measures in particular. One is the well-known cosine. The other two similarity measures have not been used before in the bibliometric literature. Finally, we show by means of an example that our findings have a high practical relevance.information science;Pearson correlation;cosine;similarity measure;author cocitation analysis

    Novel electrode systems for amperometric sensing: the case of titanium

    No full text
    fter working for years on organic materials, e.g., polythiophenes and relevant composites with metal nanoparticles, we shifted our attention to unusual metals, chosen as candidates to effective amperometric sensing on the basis of the atomic structure and crystalline properties. The present contribution aims at proposing an electrode material rarely employed in electroanalysis, namely Ti. We have experimented that the peculiar nature of Ti leads to electrochemical behavior quite different with respect to the conventional electrode materials, including those based on TiO2 (nano) particles. Our work focuses on the determination of strong oxidizing species, namely H2O2 and HClO, and noble metal ions, namely Au(III). Strong oxidizing species are commodity chemicals employed in a number of different industrial processes, in which usually high concentration levels should be monitored. The procedures proposed have been successfully applied also in complex matrices, such as detergent samples. As to Au(III) determination, it also constitutes a crucial tool in order to increase the efficiency of hydrometallurgic processes and of the recovery of precious materials from electronic waste. Ti electrodes allow the determination of dissolved Au species in the presence of other metal ions. In any cases the electrodes exhibit reproducible and repeatable electrochemical responses, even in the presence of high concentration of organic fouling species typical of bio-sorption processes

    Dispelling the Myths Behind First-author Citation Counts

    Full text link
    We conducted a full-scale evaluative citation analysis study of scholars in the XML research field to explore just how different from each other author rankings resulting from different citation counting methods actually are, and to demonstrate the capability of emerging data and tools on the Web in supporting more realistic citation counting methods. Our results contest some common arguments for the continued use of first-author citation counts in the evaluation of scholars, such as high correlations between author rankings by first-author citation counts and other citation counting methods, and high costs of using more realistic citation counting methods that are not well-supported by the ISI databases. It is argued that increasingly available digital full text research papers make it possible for citation analysis studies to go beyond what the ISI databases have directly supported and to employ more sophisticated methods

    Author Index

    No full text
    Nao informado

    Highly sensitive amperometric sensor for morphine detection based on electrochemically exfoliated graphene oxide. Application in screening tests of urine samples

    Full text link
    Graphene oxide modified screen-printed electrodes have been tested as amperometric sensors for morphine determination. The results demonstrate that the arising of electrocatalytic processes ascribable to the graphene coating, combined with the use of a suitable cleaning procedure, allow the sensor to achieve higher sensitivity (2.61 nA ppb−1) and lower limit of detection (2.5 ppb) with respect to those reported in the literature for similar devices. Due to very low detection limit found, the device is suitable to detect the presence of morphine in urine samples after a very simple and rapid pre-treatment of the matrix, allowing the removal of interfering species affecting the voltammetric responses. Tests performed in synthetic urine samples demonstrate that the presence of the electrocatalytic coating is mandatory in resolving the peak due to morphine oxidation in respect to uric acid. The sensor proposed is, thus, suitable to detect this drug even at concentration values below the cut-off levels defined by European and American regulations. These results allow us to propose the sensor for screening tests in portable devices, to be applied in systematic controls of drug abuses, e.g. in drivers and in men at work
    corecore