1,720,956 research outputs found

    Going Beyond Counting First Authors in Author Co-citation Analysis

    Get PDF
    The present study examines one of the fundamental aspects of author co-citation analysis (ACA) - the way co-citation counts are defined. Co-citation counting provides the data on which all subsequent statistical analyses and mappings are based, and we compare ACA results based on two different types of co-citation counting - the traditional type that only counts the first one among a cited work's authors on the one hand and a non-traditional type that takes into account the first 5 authors of a cited work on the other hand. Results indicate that the picture produced through this non-traditional author co-citation counting contains more coherent author groups and is therefore considerably clearer. However, this picture represents fewer specialties in the research field being studied than that produced through the traditional first-author co-citation counting when the same number of top-ranked authors is selected and analyzed. Reasons for these effects are discussed

    Variations on the Author

    Get PDF
    “Variations on the Author” discusses two of Eduardo Coutinho’s recent films (Um Dia na Vida, from 2010, and Últimas Conversas, posthumously released in 2015) and their contribution to the general question of documentary authorship. The director’s filmography is characterized by a consistent yet self-effacing form of authorial self-inscription: Coutinho often features as an interviewer that rather than express opinions propels discourses; an interviewer that is good at listening. This mode of self-inscription characterizes him as an author who is not expressive but who is nonetheless markedly present on the screen. In Um Dia na Vida, however, Coutinho is completely absent form the image, while Últimas Conversas, on the contrary, includes a confessional prologue that moves the director from the margins to the center of his films. This article examines the ways in which these works stand out in the filmography of a director who offers new insights into the notion of cinematic authorship

    Appropriate Similarity Measures for Author Cocitation Analysis

    Get PDF
    We provide a number of new insights into the methodological discussion about author cocitation analysis. We first argue that the use of the Pearson correlation for measuring the similarity between authors’ cocitation profiles is not very satisfactory. We then discuss what kind of similarity measures may be used as an alternative to the Pearson correlation. We consider three similarity measures in particular. One is the well-known cosine. The other two similarity measures have not been used before in the bibliometric literature. Finally, we show by means of an example that our findings have a high practical relevance.information science;Pearson correlation;cosine;similarity measure;author cocitation analysis

    Development of superconducting antennas based on SQUID arrays for low-field nuclear magnetic resonance

    No full text
    L'imagerie par résonance magnétique (IRM) est une modalité qui offre de bons contrastes et une bonne résolution spatiale, mais qui souffre d'un important problème de sensibilité. Pour répondre à cette problématique, le paradigme actuel est d'accroitre le champ magnétique des aimants d'IRM. Ceci mène toutefois à une explosion des coûts et à des contraintes accrues vis-à-vis des patients. L'approche que nous présentons est radicalement différente~: il s'agit de travailler à champ faible. Les antennes classiques n'étant pas assez sensibles pour recueillir le signal, l'idée est d'utiliser des SQIF. Ces derniers sont une nouvelle technologie d'antennes supraconductrices ultra-sensibles basées sur les réseaux de SQUID. Le projet vise à optimiser les capteurs SQIF et à les adapter pour la première fois à la RMN afin de mesurer un signal sur un aimant à 0.2~T.Pour ce faire, nous avons développé et étudié les performances de nouvelles architectures d'antennes SQIF afin de définir la géométrie la plus adaptée à la RMN. Nous avons également cherché à mieux comprendre comment le contexte d'utilisation de ces nouvelles antennes pouvait influencer leurs performances. Le jeu d'antennes le plus performant réalisé avait un facteur de transfert de 8.4~kVperT et un seuil de détection de 190~fTperHz. Il fut également observé que la présence d'un champ magnétique pendant le refroidissement de ces capteurs supraconducteurs dégradait leur réponse, phénomène à prendre en compte en RMN.Un Démonstrateur Super-QIF intégrant un SQIF dans l'IRM à 0.2~T fut conçu en tenant compte des contraintes géométriques et de l'environnement magnétique. Après sa fabrication, la température du cryostat était de 50~K, donc suffisante pour le bon fonctionnement des SQIF. Les premiers tests ont montrés que la présence du système ne perturbait pas le signal de RMN.Le démonstrateur est toujours en cours de développement et devrait permettre de mesurer un de RMN dans les mois à venir. À long terme, ces travaux pavent la voie à des applications des SQIF en IRM à champ terrestre.Magnetic resonance imaging (MRI) is a modality that offers good contrasts and good spatial resolution, but suffers from a significant sensitivity problem. To address this issue, the current paradigm is to increase the magnetic field of MRI magnets. However, this leads to an explosion of costs and to increased constraints on patients. The approach we present is radically different: it involves working in a weak field. As conventional antennas are not sensitive enough to collect the signal, the idea is to use SQIF. These are a new ultra sensitive superconducting antenna technology based on SQUID networks. The project aims to optimize SQIF technology and adapt it to measure an NMR signal in a 0.2~T magnet.To do this, we developed and studied the performance of new SQIF antenna architectures in order to define the geometry most suitable for NMR. We also sought to better understand how the context of use of these new antennas could influence their performance. The best performing antennas set had a transfer factor of 8.4~kVperT and a detection threshold of 190~fTperHz. It was also observed that the presence of a magnetic field during the cooling of these superconducting sensors degraded their response, a phenomenon to be accounted for in NMR.The Super-QIF Demonstrator incorporating a SQIF in the 0.2~T MRI was designed considering the geometric constraints and the magnetic environment. After its assembly, the temperature of the cryostat was 50~K, therefore sufficient for the proper operation of SQIF. The first tests showed that the system presence did not disturb the NMR signal.The demonstrator is still under development and is expected to measure an NMR signal in the forthcoming months. In the long term, this work paves the way for applications of SQIF in Earth's field MRI

    Développement d'antennes supraconductrices basées sur les réseaux de SQUID pour la résonance magnétique nucléaire à champ faible

    No full text
    Magnetic resonance imaging (MRI) is a modality that offers good contrasts and good spatial resolution, but suffers from a significant sensitivity problem. To address this issue, the current paradigm is to increase the magnetic field of MRI magnets. However, this leads to an explosion of costs and to increased constraints on patients. The approach we present is radically different: it involves working in a weak field. As conventional antennas are not sensitive enough to collect the signal, the idea is to use SQIF. These are a new ultra sensitive superconducting antenna technology based on SQUID networks. The project aims to optimize SQIF technology and adapt it to measure an NMR signal in a 0.2~T magnet.To do this, we developed and studied the performance of new SQIF antenna architectures in order to define the geometry most suitable for NMR. We also sought to better understand how the context of use of these new antennas could influence their performance. The best performing antennas set had a transfer factor of 8.4~kVperT and a detection threshold of 190~fTperHz. It was also observed that the presence of a magnetic field during the cooling of these superconducting sensors degraded their response, a phenomenon to be accounted for in NMR.The Super-QIF Demonstrator incorporating a SQIF in the 0.2~T MRI was designed considering the geometric constraints and the magnetic environment. After its assembly, the temperature of the cryostat was 50~K, therefore sufficient for the proper operation of SQIF. The first tests showed that the system presence did not disturb the NMR signal.The demonstrator is still under development and is expected to measure an NMR signal in the forthcoming months. In the long term, this work paves the way for applications of SQIF in Earth's field MRI.L'imagerie par résonance magnétique (IRM) est une modalité qui offre de bons contrastes et une bonne résolution spatiale, mais qui souffre d'un important problème de sensibilité. Pour répondre à cette problématique, le paradigme actuel est d'accroitre le champ magnétique des aimants d'IRM. Ceci mène toutefois à une explosion des coûts et à des contraintes accrues vis-à-vis des patients. L'approche que nous présentons est radicalement différente~: il s'agit de travailler à champ faible. Les antennes classiques n'étant pas assez sensibles pour recueillir le signal, l'idée est d'utiliser des SQIF. Ces derniers sont une nouvelle technologie d'antennes supraconductrices ultra-sensibles basées sur les réseaux de SQUID. Le projet vise à optimiser les capteurs SQIF et à les adapter pour la première fois à la RMN afin de mesurer un signal sur un aimant à 0.2~T.Pour ce faire, nous avons développé et étudié les performances de nouvelles architectures d'antennes SQIF afin de définir la géométrie la plus adaptée à la RMN. Nous avons également cherché à mieux comprendre comment le contexte d'utilisation de ces nouvelles antennes pouvait influencer leurs performances. Le jeu d'antennes le plus performant réalisé avait un facteur de transfert de 8.4~kVperT et un seuil de détection de 190~fTperHz. Il fut également observé que la présence d'un champ magnétique pendant le refroidissement de ces capteurs supraconducteurs dégradait leur réponse, phénomène à prendre en compte en RMN.Un Démonstrateur Super-QIF intégrant un SQIF dans l'IRM à 0.2~T fut conçu en tenant compte des contraintes géométriques et de l'environnement magnétique. Après sa fabrication, la température du cryostat était de 50~K, donc suffisante pour le bon fonctionnement des SQIF. Les premiers tests ont montrés que la présence du système ne perturbait pas le signal de RMN.Le démonstrateur est toujours en cours de développement et devrait permettre de mesurer un de RMN dans les mois à venir. À long terme, ces travaux pavent la voie à des applications des SQIF en IRM à champ terrestre

    Développement d'antennes supraconductrices basées sur les réseaux de SQUID pour la résonance magnétique nucléaire à champ faible

    Get PDF
    Magnetic resonance imaging (MRI) is a modality that offers good contrasts and good spatial resolution, but suffers from a significant sensitivity problem. To address this issue, the current paradigm is to increase the magnetic field of MRI magnets. However, this leads to an explosion of costs and to increased constraints on patients. The approach we present is radically different: it involves working in a weak field. As conventional antennas are not sensitive enough to collect the signal, the idea is to use SQIF. These are a new ultra sensitive superconducting antenna technology based on SQUID networks. The project aims to optimize SQIF technology and adapt it to measure an NMR signal in a 0.2~T magnet.To do this, we developed and studied the performance of new SQIF antenna architectures in order to define the geometry most suitable for NMR. We also sought to better understand how the context of use of these new antennas could influence their performance. The best performing antennas set had a transfer factor of 8.4~kVperT and a detection threshold of 190~fTperHz. It was also observed that the presence of a magnetic field during the cooling of these superconducting sensors degraded their response, a phenomenon to be accounted for in NMR.The Super-QIF Demonstrator incorporating a SQIF in the 0.2~T MRI was designed considering the geometric constraints and the magnetic environment. After its assembly, the temperature of the cryostat was 50~K, therefore sufficient for the proper operation of SQIF. The first tests showed that the system presence did not disturb the NMR signal.The demonstrator is still under development and is expected to measure an NMR signal in the forthcoming months. In the long term, this work paves the way for applications of SQIF in Earth's field MRI.L'imagerie par résonance magnétique (IRM) est une modalité qui offre de bons contrastes et une bonne résolution spatiale, mais qui souffre d'un important problème de sensibilité. Pour répondre à cette problématique, le paradigme actuel est d'accroitre le champ magnétique des aimants d'IRM. Ceci mène toutefois à une explosion des coûts et à des contraintes accrues vis-à-vis des patients. L'approche que nous présentons est radicalement différente~: il s'agit de travailler à champ faible. Les antennes classiques n'étant pas assez sensibles pour recueillir le signal, l'idée est d'utiliser des SQIF. Ces derniers sont une nouvelle technologie d'antennes supraconductrices ultra-sensibles basées sur les réseaux de SQUID. Le projet vise à optimiser les capteurs SQIF et à les adapter pour la première fois à la RMN afin de mesurer un signal sur un aimant à 0.2~T.Pour ce faire, nous avons développé et étudié les performances de nouvelles architectures d'antennes SQIF afin de définir la géométrie la plus adaptée à la RMN. Nous avons également cherché à mieux comprendre comment le contexte d'utilisation de ces nouvelles antennes pouvait influencer leurs performances. Le jeu d'antennes le plus performant réalisé avait un facteur de transfert de 8.4~kVperT et un seuil de détection de 190~fTperHz. Il fut également observé que la présence d'un champ magnétique pendant le refroidissement de ces capteurs supraconducteurs dégradait leur réponse, phénomène à prendre en compte en RMN.Un Démonstrateur Super-QIF intégrant un SQIF dans l'IRM à 0.2~T fut conçu en tenant compte des contraintes géométriques et de l'environnement magnétique. Après sa fabrication, la température du cryostat était de 50~K, donc suffisante pour le bon fonctionnement des SQIF. Les premiers tests ont montrés que la présence du système ne perturbait pas le signal de RMN.Le démonstrateur est toujours en cours de développement et devrait permettre de mesurer un de RMN dans les mois à venir. À long terme, ces travaux pavent la voie à des applications des SQIF en IRM à champ terrestre

    Dispelling the Myths Behind First-author Citation Counts

    Get PDF
    We conducted a full-scale evaluative citation analysis study of scholars in the XML research field to explore just how different from each other author rankings resulting from different citation counting methods actually are, and to demonstrate the capability of emerging data and tools on the Web in supporting more realistic citation counting methods. Our results contest some common arguments for the continued use of first-author citation counts in the evaluation of scholars, such as high correlations between author rankings by first-author citation counts and other citation counting methods, and high costs of using more realistic citation counting methods that are not well-supported by the ISI databases. It is argued that increasingly available digital full text research papers make it possible for citation analysis studies to go beyond what the ISI databases have directly supported and to employ more sophisticated methods

    Author Index

    No full text
    Nao informado

    koamabayili/VECTRON-author-checklist: VECTRON author checklist

    No full text
    We have done our best to complete the author checklist relating to the use of animals in the hut study. Note that the objective for the hut study was to evaluate the IRS treatment applications for residual efficacy against Anopheles mosquitoes, including the local An. coluzzii mosquito population. Cows were only used to attract mosquitoes into the huts and no tests were carried out directly on the cows. The author checklist is intended for use with studies where experiments are carried out on animals, which is why we have had such difficulty in completing this for the hut study, as many of the questions do not relate to how the cows were used
    corecore