104,874 research outputs found

    An ISPA-camera for gamma rays

    No full text
    With the recently developed ISPA (Imaging Silicon Pixel Array)-tube attached either to a planar YAlO3(Ce) (YAP) disc (1mm thick) or to a matrix of optically-separated YAP-crystals (5mm high, 0.6 x 0.6 mm2 cross-section) we achieved high spatial resolution of 57Co-122 keV photons. The vacuum-sealed ISPA-tube is only 4 cm long with 3.5 cm diameter and consists of a photocathode viewed at 3 cm distance by a silicon pixel chip, directly detecting the photoelectrons. The chip-anode consists of 1024 rectangular pixels with 75 µm x 500 µm edges, each bump-bonded to their individual front-end electronics. The total pixel array read-out time is 10 µs. The measured intrinsic spatial resolutions (FWHM) of this ISPA-camera are 700 µm (planar YAP) and 310 µm (YAP-matrix). Apart from its already demonstrated application for particle tracking with scintillating fibres, the ISPA-tube provides also an excellent tool in medicine, biology and chemistry

    Going Beyond Counting First Authors in Author Co-citation Analysis

    No full text
    The present study examines one of the fundamental aspects of author co-citation analysis (ACA) - the way co-citation counts are defined. Co-citation counting provides the data on which all subsequent statistical analyses and mappings are based, and we compare ACA results based on two different types of co-citation counting - the traditional type that only counts the first one among a cited work's authors on the one hand and a non-traditional type that takes into account the first 5 authors of a cited work on the other hand. Results indicate that the picture produced through this non-traditional author co-citation counting contains more coherent author groups and is therefore considerably clearer. However, this picture represents fewer specialties in the research field being studied than that produced through the traditional first-author co-citation counting when the same number of top-ranked authors is selected and analyzed. Reasons for these effects are discussed

    Appropriate Similarity Measures for Author Cocitation Analysis

    No full text
    We provide a number of new insights into the methodological discussion about author cocitation analysis. We first argue that the use of the Pearson correlation for measuring the similarity between authors’ cocitation profiles is not very satisfactory. We then discuss what kind of similarity measures may be used as an alternative to the Pearson correlation. We consider three similarity measures in particular. One is the well-known cosine. The other two similarity measures have not been used before in the bibliometric literature. Finally, we show by means of an example that our findings have a high practical relevance.information science;Pearson correlation;cosine;similarity measure;author cocitation analysis
    corecore