1,721,034 research outputs found

    Apport de l'assistance par ordinateur lors de la pose d'endoprothèse aortique

    Full text link
    The development of endovascular aortic procedures is growing. These mini-invasive techniques allow a reduction of surgical trauma, usually important in conventional open surgery. The technical limitations of endovascular repair are pushed to special aortic localizations which were in the past decade indication for open repair. Success and efficiency of such procedures are based on the development and the implementation of decision-making tools. This work aims to improve endovascular procedures thanks to a better utilization of pre and intraoperative imaging. This approach is in the line with the framework of computer-assisted surgery whose concepts are applied to vascular surgery. The optimization of endograft deployment is considered in three steps. The first part is dedicated to preoperative imaging analysis and shows the limits of the current sizing tools. The accuracy of a new measurement criterion is assessed (outer curvature length). The second part deals with intraoperative imaging and shows the contribution of augmented reality in endovascular aortic repair. In the last part, image guided surgery on soft tissues is addressed, especially the arterial deformations occurring during endovascular procedures which disprove rigid registration in fusion imaging. The use of finite element simulation to deal with this issue is presented. We report an original approach based on a predictive model of deformations using finite element simulation with geometrical and anatomo-mechanical patient specific parameters extracted from the preoperative CT-scan.Les techniques endovasculaires, particulièrement pour l’aorte, sont en plein essor en chirurgie vasculaire. Ces techniques mini-invasives permettent de diminuer l’agression chirurgicale habituellement importante lors de la chirurgie conventionnelle. Les limites techniques sont repoussées à certaines localisations de l’aorte qui étaient il y a encore peu de temps inaccessibles aux endoprothèses. Le succès et l’efficience de ces interventions reposent en partie sur l'élaboration et la mise en œuvre de nouveaux outils d'aide à la décision. Ce travail entend contribuer à l’amélioration des procédures interventionnelles aortiques grâce à une meilleure exploitation de l’imagerie pré et peropératoire. Cette démarche s’inscrit dans le cadre plus général des Gestes Médico-Chirurgicaux Assistés par Ordinateur, dont les concepts sont revisités pour les transposer au domaine de la chirurgie endovasculaire. Trois axes sont développés afin de sécuriser et optimiser la pose d'endoprothèse. Le premier est focalisé sur l’analyse préopératoire du scanner (sizing) et montre les limites des outils de mesure actuels et évalue la précision d’un nouveau critère de mesure des longueurs de l’aorte (courbure externe). Le deuxième axe se positionne sur le versant peropératoire et montre la contribution de la réalité augmentée dans la pose d’une endoprothèse aortique. Le troisième axe s’intéresse au problème plus général des interventions sur les tissus mous et particulièrement aux déformations artérielles qui surviennent au cours des procédures interventionnelles qui mettent en défaut le recalage rigide lors de la fusion d’images. Nous présentons une approche originale basée sur un modèle numérique de prédiction des déformations qui utilise la simulation par éléments finis en y intégrant des paramètres géométriques et anatomo-mécaniques spécifique-patient extraits du scanner préopératoire

    Computer aided surgery in endovascular aortic procedures

    No full text
    Les techniques endovasculaires, particulièrement pour l’aorte, sont en plein essor en chirurgie vasculaire. Ces techniques mini-invasives permettent de diminuer l’agression chirurgicale habituellement importante lors de la chirurgie conventionnelle. Les limites techniques sont repoussées à certaines localisations de l’aorte qui étaient il y a encore peu de temps inaccessibles aux endoprothèses. Le succès et l’efficience de ces interventions reposent en partie sur l'élaboration et la mise en œuvre de nouveaux outils d'aide à la décision. Ce travail entend contribuer à l’amélioration des procédures interventionnelles aortiques grâce à une meilleure exploitation de l’imagerie pré et peropératoire. Cette démarche s’inscrit dans le cadre plus général des Gestes Médico-Chirurgicaux Assistés par Ordinateur, dont les concepts sont revisités pour les transposer au domaine de la chirurgie endovasculaire. Trois axes sont développés afin de sécuriser et optimiser la pose d'endoprothèse. Le premier est focalisé sur l’analyse préopératoire du scanner (sizing) et montre les limites des outils de mesure actuels et évalue la précision d’un nouveau critère de mesure des longueurs de l’aorte (courbure externe). Le deuxième axe se positionne sur le versant peropératoire et montre la contribution de la réalité augmentée dans la pose d’une endoprothèse aortique. Le troisième axe s’intéresse au problème plus général des interventions sur les tissus mous et particulièrement aux déformations artérielles qui surviennent au cours des procédures interventionnelles qui mettent en défaut le recalage rigide lors de la fusion d’images. Nous présentons une approche originale basée sur un modèle numérique de prédiction des déformations qui utilise la simulation par éléments finis en y intégrant des paramètres géométriques et anatomo-mécaniques spécifique-patient extraits du scanner préopératoire.The development of endovascular aortic procedures is growing. These mini-invasive techniques allow a reduction of surgical trauma, usually important in conventional open surgery. The technical limitations of endovascular repair are pushed to special aortic localizations which were in the past decade indication for open repair. Success and efficiency of such procedures are based on the development and the implementation of decision-making tools. This work aims to improve endovascular procedures thanks to a better utilization of pre and intraoperative imaging. This approach is in the line with the framework of computer-assisted surgery whose concepts are applied to vascular surgery. The optimization of endograft deployment is considered in three steps. The first part is dedicated to preoperative imaging analysis and shows the limits of the current sizing tools. The accuracy of a new measurement criterion is assessed (outer curvature length). The second part deals with intraoperative imaging and shows the contribution of augmented reality in endovascular aortic repair. In the last part, image guided surgery on soft tissues is addressed, especially the arterial deformations occurring during endovascular procedures which disprove rigid registration in fusion imaging. The use of finite element simulation to deal with this issue is presented. We report an original approach based on a predictive model of deformations using finite element simulation with geometrical and anatomo-mechanical patient specific parameters extracted from the preoperative CT-scan

    Going Beyond Counting First Authors in Author Co-citation Analysis

    Full text link
    The present study examines one of the fundamental aspects of author co-citation analysis (ACA) - the way co-citation counts are defined. Co-citation counting provides the data on which all subsequent statistical analyses and mappings are based, and we compare ACA results based on two different types of co-citation counting - the traditional type that only counts the first one among a cited work's authors on the one hand and a non-traditional type that takes into account the first 5 authors of a cited work on the other hand. Results indicate that the picture produced through this non-traditional author co-citation counting contains more coherent author groups and is therefore considerably clearer. However, this picture represents fewer specialties in the research field being studied than that produced through the traditional first-author co-citation counting when the same number of top-ranked authors is selected and analyzed. Reasons for these effects are discussed

    Variations on the Author

    Full text link
    “Variations on the Author” discusses two of Eduardo Coutinho’s recent films (Um Dia na Vida, from 2010, and Últimas Conversas, posthumously released in 2015) and their contribution to the general question of documentary authorship. The director’s filmography is characterized by a consistent yet self-effacing form of authorial self-inscription: Coutinho often features as an interviewer that rather than express opinions propels discourses; an interviewer that is good at listening. This mode of self-inscription characterizes him as an author who is not expressive but who is nonetheless markedly present on the screen. In Um Dia na Vida, however, Coutinho is completely absent form the image, while Últimas Conversas, on the contrary, includes a confessional prologue that moves the director from the margins to the center of his films. This article examines the ways in which these works stand out in the filmography of a director who offers new insights into the notion of cinematic authorship

    Appropriate Similarity Measures for Author Cocitation Analysis

    Full text link
    We provide a number of new insights into the methodological discussion about author cocitation analysis. We first argue that the use of the Pearson correlation for measuring the similarity between authors’ cocitation profiles is not very satisfactory. We then discuss what kind of similarity measures may be used as an alternative to the Pearson correlation. We consider three similarity measures in particular. One is the well-known cosine. The other two similarity measures have not been used before in the bibliometric literature. Finally, we show by means of an example that our findings have a high practical relevance.information science;Pearson correlation;cosine;similarity measure;author cocitation analysis

    Dispelling the Myths Behind First-author Citation Counts

    Full text link
    We conducted a full-scale evaluative citation analysis study of scholars in the XML research field to explore just how different from each other author rankings resulting from different citation counting methods actually are, and to demonstrate the capability of emerging data and tools on the Web in supporting more realistic citation counting methods. Our results contest some common arguments for the continued use of first-author citation counts in the evaluation of scholars, such as high correlations between author rankings by first-author citation counts and other citation counting methods, and high costs of using more realistic citation counting methods that are not well-supported by the ISI databases. It is argued that increasingly available digital full text research papers make it possible for citation analysis studies to go beyond what the ISI databases have directly supported and to employ more sophisticated methods

    Author Index

    No full text
    Nao informado

    koamabayili/VECTRON-author-checklist: VECTRON author checklist

    No full text
    We have done our best to complete the author checklist relating to the use of animals in the hut study. Note that the objective for the hut study was to evaluate the IRS treatment applications for residual efficacy against Anopheles mosquitoes, including the local An. coluzzii mosquito population. Cows were only used to attract mosquitoes into the huts and no tests were carried out directly on the cows. The author checklist is intended for use with studies where experiments are carried out on animals, which is why we have had such difficulty in completing this for the hut study, as many of the questions do not relate to how the cows were used

    Facteurs prédictifs préopératoires de régression du sac anévrysmal après traitement endovasculaire des anévrysmes de l'aorte abdominale

    No full text
    But: la régression du sac anévrysmale après traitement endovasculaire (EVAR) est un marqueur fiable de succès à long terme. Le but de cette étude était d'identifier les facteurs prédictifs de régression du sac selon les normes internationales de description anatomique des AAA. Méthodes: sur 199 patients opérés d'un AAA par voie endovasculaire entre 2000 et 2009, 164 est un suivi scannographique et échographique complet ont été inclus dans cette étude rétrospective. Pour être inclus, tous les angioscanners devaient être analysables avec un logiciel permettant d'effectuer des mesures tridimensionnelles (Endosize® , Rennes, France). Chaque paramètre anatomique a été catégorisé selon 4 grades de sévérité conformément aux reporting standard de la société internationale de chirurgie vasculaire. A partir de ces grades, un score de gravité anatomique a été calculé au niveau du collet, de l'AAA et des artères iliaques. Les facteurs cliniques et démographiques ont également été étudiés. Les patients présentant une régression>=5mm de leur AAA au cours du suivi appartenaient au groupe A, les autres au groupe B. Résultats: les taux de régression était de 40,2% (groupe A, n=66). L'âge moyen dans le groupe A était de 71.4+- 8.9 ans et de 76.3+-8.3 ans dans le groupe B (P=5 mm were assigned to group A, and the others were assigned to group B. Results: aneurysmal regression occured in 66 (40.2%) patients (group A). The mean age was 71.4+-8.9 years in group A, and 76.3+-8.3 in group B. Univariate analyses showed sllmaller severity scores at the aortic neck (p=0.05) and the iliac arteries (p=0.002) in group A. In group A, calcifications and thrombus were less significant at the aortic neck (p=0.003 and p=0.02) and at the iliac arteries (p=0.001 et p=0.02), and inferior mesenteric artery patency was less frequent (68.2% vs 82.7%, p=0.04). Two multivariate analyses were carried out, of which one considered the scores, and the other was based on the variables included in the scores. In the first, the patients of group A were younger (p=0.002) and aortic neck calcifications were less significant (p=0.007). In the second, the patients of group Awere younger (p<0.001) and the aortic neck scores were smaller (p=0.04). There was no difference between the two groups, in terms of the implanted endoprosthesis, nor in the follow-up (46.4+-24 months in group A, and 47.2+-22 months in group B, p=0.35). Conclusion: in this study, the young age of the patients and their aortic neck quality, in particular the absence of neck calcification, appear to have been the main factors affecting aneurysm shrinkage, such that they represent a target population for the improvement of EVAR resultsRENNES1-BU Santé (352382103) / SudocSudocFranceF
    corecore