1,721,179 research outputs found

    Going Beyond Counting First Authors in Author Co-citation Analysis

    Get PDF
    The present study examines one of the fundamental aspects of author co-citation analysis (ACA) - the way co-citation counts are defined. Co-citation counting provides the data on which all subsequent statistical analyses and mappings are based, and we compare ACA results based on two different types of co-citation counting - the traditional type that only counts the first one among a cited work's authors on the one hand and a non-traditional type that takes into account the first 5 authors of a cited work on the other hand. Results indicate that the picture produced through this non-traditional author co-citation counting contains more coherent author groups and is therefore considerably clearer. However, this picture represents fewer specialties in the research field being studied than that produced through the traditional first-author co-citation counting when the same number of top-ranked authors is selected and analyzed. Reasons for these effects are discussed

    Photodynamic effect of argon and diode laser on cholesteatoma cell cultures after intravital staining with absorption enhancers

    No full text
    Sedlmaier B, Franke A, Sudhoff H, Jovanovic S, Haisch A. Photodynamic effect of argon and diode laser on cholesteatoma cell cultures after intravital staining with absorption enhancers. Lasers in Medical Science. 2005;19(4):248-256

    Variations on the Author

    Get PDF
    “Variations on the Author” discusses two of Eduardo Coutinho’s recent films (Um Dia na Vida, from 2010, and Últimas Conversas, posthumously released in 2015) and their contribution to the general question of documentary authorship. The director’s filmography is characterized by a consistent yet self-effacing form of authorial self-inscription: Coutinho often features as an interviewer that rather than express opinions propels discourses; an interviewer that is good at listening. This mode of self-inscription characterizes him as an author who is not expressive but who is nonetheless markedly present on the screen. In Um Dia na Vida, however, Coutinho is completely absent form the image, while Últimas Conversas, on the contrary, includes a confessional prologue that moves the director from the margins to the center of his films. This article examines the ways in which these works stand out in the filmography of a director who offers new insights into the notion of cinematic authorship

    Appropriate Similarity Measures for Author Cocitation Analysis

    Get PDF
    We provide a number of new insights into the methodological discussion about author cocitation analysis. We first argue that the use of the Pearson correlation for measuring the similarity between authors’ cocitation profiles is not very satisfactory. We then discuss what kind of similarity measures may be used as an alternative to the Pearson correlation. We consider three similarity measures in particular. One is the well-known cosine. The other two similarity measures have not been used before in the bibliometric literature. Finally, we show by means of an example that our findings have a high practical relevance.information science;Pearson correlation;cosine;similarity measure;author cocitation analysis

    Dispelling the Myths Behind First-author Citation Counts

    Get PDF
    We conducted a full-scale evaluative citation analysis study of scholars in the XML research field to explore just how different from each other author rankings resulting from different citation counting methods actually are, and to demonstrate the capability of emerging data and tools on the Web in supporting more realistic citation counting methods. Our results contest some common arguments for the continued use of first-author citation counts in the evaluation of scholars, such as high correlations between author rankings by first-author citation counts and other citation counting methods, and high costs of using more realistic citation counting methods that are not well-supported by the ISI databases. It is argued that increasingly available digital full text research papers make it possible for citation analysis studies to go beyond what the ISI databases have directly supported and to employ more sophisticated methods

    Author Index

    No full text
    Nao informado

    Platform switching versus regular platform implants: 3-year post-loading results from a randomised controlled trial

    No full text
    Purpose: To test the hypothesis that platform switching and regular platform implants would have different outcomes in single-tooth replacement against the alternative hypothesis of no difference. Material and methods: This study was designed as a randomised controlled split-mouth trial. Eighteen patients with bilaterally missing single premolars or molars to be restored with implantsupported single crowns, were consecutively enrolled. Implant sites were randomly assigned to be treated according to the platform switching concept (PS group), or with matching implant-abutment diameters (RP group). A total of 36 Nobel Replace Tapered Groovy implants were installed. All the implants were inserted in healed bone, with an insertion torque between 35 and 45 Ncm, according to a one-stage protocol. Both implant types were loaded with a screw-retained temporary crown 3 months after implant insertion. Definitive screw-retained single crowns were delivered 2 months later. Outcome measures were implant and prosthetic survival rates, biological and prosthetic complications, radiographic marginal bone level (MBL) changes, pocket probing depth (PPD) and bleeding on probing (BOP). Clinical data was collected at implant placement (baseline), and at 3, 9 and 36 months after loading. Results: No patients dropped out and no implant failed. No prosthetic complications were recorded. One patient experienced mucosal inflammation with positive BOP (RP group) after 3 months, three patients had bilateral peri-implant mucosal inflammation with positive BOP at 6, 24 and 30 months after loading, respectively. There were no statistically significant differences between groups for complications (3/18 versus 4/18; P = 1.0; Odds Ratio = 1.333; 95% CI: 0.3467 to 5.1272). Nine months after loading, the mean MBL was 0.93 ± 0.26 mm in the RP group and 0.84 ± 0.23 mm in the PS group, with no statistically significant differences between groups (mean difference = 0.09 mm, 95% CI: -0.22 to 0.04, P = 0.18). Three years after loading, mean MBL was 1.09 ± 0.31 mm in the RP group and 1.06 ± 0.24 mm in the PS group, with no statistically significant differences between groups (mean difference = 0.02 mm, 95% CI: -0.06 to 0.10, P = 0.70). Marginal bone level changes between 3 years and baseline were 0.72 ± 0.28 mm in the RP group and 0.71 ± 0.27 mm in the PS group, with no statistically significant differences between the groups (mean difference = -0.00 mm, 95% CI: -0.07 to 0.07, P = 0.89). Mean PPD was 2.70 ± 0.52 mm in the RP group and 2.46 ± 0.69 mm in the PS group at 36 months after loading, with no statistically significant differences between the groups (mean difference = 0.23 mm, 95% CI: -0.05 to 0.35, P = 0.43). Mean BOP was 0.83 ± 0.96 mm in the RP group and 0.89 ± 0.99 mm in the PS group at 36 months after loading, with no statistically significant differences between the groups (mean difference = 0.07 mm, 95% CI: -0.03 to 0.17, P = 0.77). Conclusions: The clinical and radiographic outcomes of implants restored according to the platformswitching concept versus implants restored with the matching implant-abutment diameters are comparable, 3 years after loading

    CITIZEN SCIENCE for WATER QUALITY MONITORING APPLYING FOSS

    Get PDF
    Citizen science is an efficient tool for data collection for scientific projects. In the framework of SIMILE Interreg Italy-Switzerland project, the citizen's contribution to monitor the quality of lakes water has been envisaged. In the initial phase of this research, state of art of citizen science and water quality monitoring was investigated. The analysis of past and current projects, governed by different organizations and communities, pointed out a variety of tasks that can be accomplished by citizens. In these studies, authors stressed suitability of smartphones for the fulfilment of various assignments given to citizens. Due to that, in this research, different smartphone applications for water quality monitoring were tested and analyzed. Despite the fact that many applications for water quality monitoring are freely available, none of them is open source. Hence, this paper is proposing the design of a new application, for the purposes of SIMILE project, that will be free and open source, addressing not just users but also developers giving them a possibility for customization and improvement
    corecore