124 research outputs found

    Assessing and minimizing the effects of noise and motion in clinical DTI at 3 T

    No full text
    Compared with conventional MRI, diffusion tensor imaging (DTI) is more prone to thermal noise and motion. Optimized sampling schemes have been proposed that reduce the propagation of noise. At 3 T, however, motion may play a more dominant role than noise. Although the effects of noise at 3 T are less compared with 1.5 T because of the higher signal-to-noise ratio, motion is independent of field strength and will persist. To improve the reliability of clinical DTI at 3 T, it is important to know to what extent noise and motion contribute to the uncertainties of the DTI indices. In this study, the effects of noise- and motion-related signal uncertainties are disentangled using in vivo measurements and computer simulations. For six clinically standard available sampling schemes, the reproducibility was assessed in vivo, with and without motion correction applied. Additionally, motion and noise simulations were performed to determine the relative contributions of motion and noise to the uncertainties of the mean diffusivity (MD) and fractional anisotropy (FA). It is shown that the contributions of noise and motion are of the same order of magnitude at 3 T. Similar to the propagation of noise, the propagation of motion-related signal perturbations is also influenced by the choice of sampling scheme. Sampling schemes with only six diffusion directions demonstrated a lower reproducibility compared with schemes with 15 and 32 directions and feature a positive bias for the FA in relatively isotropic tissue. Motion correction helps improving the precision and accuracy of DTI indices

    Applicability and reproducibility of 2D multi-slice GRASE myelin water fraction with varying acquisition acceleration

    Get PDF
    Non-invasive quantification of the in vivo myelin content may provide valuable information regarding healthy maturation of the brain, as well as insights into demyelination of several neurological disorders. However, these scans are often long thereby limiting acquisition of large brain parts in clinically feasible acquisition times. Therefore, fast acquisition of whole brain myelin content is important. To avoid errors related to slice-selective pulses, most of the previous whole brain studies on myelin content relied on a 3D acquisition. However, multi-slice (2D) acquisition methods are often faster, and less susceptible to motion artifacts. Therefore, multi-slice approaches can be beneficial in a clinical setting. We investigated the applicability and reproducibility of whole brain multi-slice GRASE myelin-water imaging with post-acquisition slice-profile correction in healthy volunteers (aged 25-32y). The applicability was evaluated using the agreement between the multi-slice GRASE and the reference method for myelin-water imaging, single-slice multi spin-echo (MSE) acquisition. Additionally, we assessed the effect of varying acquisition acceleration using parallel imaging on the reproducibility values. First, the multi-slice myelin-water maps showed good agreement with the single-slice reference method, with a bias of at most 1.2% in absolute MWF values. Second, we found an average within-subject coefficient of variation (CoV) of 5.9% and an average intra-class correlation coefficient (ICC) of 0.90 for myelin-water estimation using a multi-slice GRASE sequence without parallel acceleration (scan time 14:06 min), while acquisition with a parallel acceleration factor of 2 resulted in a slightly worse average within-subject CoV of 6.4% and an average ICC of 0.83 at half the scan time. Hence, a multi-slice GRASE acquisition with parallel acceleration factor 2 and a scan time of 7:30 min still provides an excellent reproducibility

    rt-me-fMRI: a task and resting state dataset for real-time, multi-echo fMRI methods development and validation

    Get PDF
    Latest published: 04 Feb 2021A multi-echo fMRI dataset (N=28 healthy participants) with four task-based and two resting state runs was collected, curated and made available to the community. Its main purpose is to advance the development of methods for real-time multi-echo functional magnetic resonance imaging (rt-me-fMRI) analysis with applications in neurofeedback, real-time quality control, and adaptive paradigms, although the variety of experimental task paradigms supports a multitude of use cases. Tasks include finger tapping, emotional face and shape matching, imagined finger tapping and imagined emotion processing. This work provides a detailed description of the full dataset; methods to collect, prepare, standardize and preprocess it; quality control measures; and data validation measures. A web-based application is provided as a supplementary tool with which to interactively explore, visualize and understand the data and its derivative measures: https://rt-me-fmri.herokuapp.com/. The dataset itself can be accessed via a data use agreement on DataverseNL at https://dataverse.nl/dataverse/rt-me-fmri. Supporting information and code for reproducibility can be accessed at https://github.com/jsheunis/rt-me-fMR

    A new analysis approach for T2 relaxometry myelin water quantification: Orthogonal Matching Pursuit

    Get PDF
    Purpose: In vivo myelin quantification can provide valuable noninvasive information on neuronal maturation and development, as well as insights into neurological disorders. Multiexponential analysis of multiecho T2 relaxation is a powerful and widely applied method for the quantification of the myelin water fraction (MWF). In recent literature, the MWF is most commonly estimated using a regularized nonnegative least squares algorithm. Methods: The orthogonal matching pursuit algorithm is proposed as an alternative method for the estimation of the MWF. The orthogonal matching pursuit is a greedy sparse reconstruction algorithm with a low computation complexity. For validation, both methods are compared to a ground truth using numerical simulations and a phantom model using comparable computation times. The numerical simulations were used to measure the theoretical errors, as well as the effects of varying the SNR, strength of the regularization, and resolution of the basis set. Additionally, a phantom model was used to estimate the performance of the 2 methods while including errors occurring due to the MR measurement. Lastly, 4 healthy subjects were scanned to evaluate the in vivo performance. Results: The results in simulations and phantoms demonstrate that the MWFs determined with the orthogonal matching pursuit are 1.7 times more accurate as compared to the nonnegative least squares, with a comparable precision. The remaining bias of the MWF is shown to be related to the regularization of the nonnegative least squares algorithm and the Rician noise present in magnitude MR images. Conclusion: The orthogonal matching pursuit algorithm provides a more accurate alternative for T2 relaxometry myelin water quantification

    Functional MRI in major depressive disorder:A review of findings, limitations, and future prospects

    Get PDF
    Objective diagnosis and prognosis in major depressive disorder (MDD) remains a challenge due to the absence of biomarkers based on physiological parameters or medical tests. Numerous studies have been conducted to identify functional magnetic resonance imaging-based biomarkers of depression that either objectively differentiate patients with depression from healthy subjects, predict personalized treatment outcome, or characterize biological subtypes of depression. While there are some findings of consistent functional biomarkers, there is still lack of robust data acquisition and analysis methodology. According to current findings, primarily, the anterior cingulate cortex, prefrontal cortex, and default mode network play a crucial role in MDD. Yet, there are also less consistent results and the involvement of other regions or networks remains ambiguous. We further discuss image acquisition, processing, and analysis limitations that might underlie these inconsistencies. Finally, the current review aims to address and discuss possible remedies and future opportunities that could improve the search for consistent functional imaging biomarkers of depression. Novel acquisition techniques, such as multiband and multiecho imaging, and neural network-based cleaning approaches can enhance the signal quality in limbic and frontal regions. More comprehensive analyses, such as directed or dynamic functional features or the identification of biological depression subtypes, can improve objective diagnosis or treatment outcome prediction and mitigate the heterogeneity of MDD. Overall, these improvements in functional MRI imaging techniques, processing, and analysis could advance the search for biomarkers and ultimately aid patients with MDD and their treatment course.</p

    Vessel architecture imaging reveals microvascular rarefaction and capillary-to-arteriole shift in cerebral small vessel disease

    No full text
    In cerebral small vessel disease, clinical imaging markers such as white matter hyperintensities are often considered late-stage indicators, with limited understanding of (early) underlying microvascular alterations. This prospective, cross-sectional study utilized vessel architecture imaging to assess microvascular alterations in vivo in 40 patients with cerebral small vessel disease and 21 controls at 3T MRI. Quantitative measures for vessel density, radius, and vessel type composition were derived. Overall, patients had lower vessel density and larger microvessel radius than controls, while blood perfusion levels remained similar between groups. Moreover, a shift from capillaries to arterioles was observed in cortical gray matter and normal-appearing white matter in patients. White matter hyperintensities demonstrated lower vessel density and larger radii than normal-appearing white matter, with no difference in vessel type composition. Our findings support the role of microvascular rarefaction in the pathophysiology of cerebral small vessel disease. The remaining vascular network with relatively more larger or more dilated (arteriolar) blood vessels and less dense microvessels may reflect uneven flow patterns, leading to less efficient delivery of oxygen, nutrients, and removal of metabolic waste products. Vessel architecture imaging can provide an early biomarker in future trials on microvascular growth therapy. Clinical Trial Registration Information: Measuring the blood vessel density in patients with heart failure or reduced cognitive function of vascular origin: CRUCIAL. https://doi.org/10.1186/ISRCTN22301128. 848109.</p
    corecore