1,488 research outputs found

    Carlos Alberto Flesch

    No full text

    Josef Flesch ex librise

    No full text
    http://www.lib.unideb.huDebreceni Egyetem Egyetemi és Nemzeti KönyvtárKözépütt fekvő könyv, rajta J. F.monogram, az F betű szára áthatol a könyvön. A könyvnek van egy könyvjelzője, ezen a készítő monogramja: "HR". A kép alatti felirat: "Dr. Josef Flesch Prague Brehová 3 a". A kép háuljára a készítő neve van pecsételve: "Robert Herrmann Praha".metszetH

    Identificação do instante de entrada em condição de regime permanente em ensaios de desempenho de compressores

    No full text
    Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico, Programa de Pós-Graduação em Metrologia Científica e Industrial, Florianópolis, 2008Para acompanhar a evolução dos sistemas de refrigeração são necessários métodos adequados de avaliação de produto. Dentre os ensaios executados com compressores herméticos para refrigeração, têm com grande importância os ensaios de desempenho. Cuja principal finalidade é estabelecer a capacidade de refrigeração, o consumo de potência ativa do compressor e o coeficiente de performance (COP). Tais ensaios são executados com elevada freqüência dentro de uma indústria de compressores. O tempo demandado e o alto investimento exigido são dois grandes problemas inerentes a esses ensaios. O comportamento das variáveis de ensaio pode ser dividido em dois momentos distintos: transitório - aquele no qual os valores das grandezas variam com grande amplitude; regime permanente - aquele no qual os valores das grandezas se confinam em faixas estabelecidas por normas ou procedimentos específicos. É nesse segundo momento - o regime permanente - que devem ser realizadas as medições de desempenho do compressor. Esta dissertação propõe a redução do tempo demandado por esses ensaios, através do emprego de redes neurais artificiais. Dois caminhos foram explorados com sucesso: identificação do instante em que condições de regime são atingidas; inferência de valores de regime a partir de dados do transitório. O primeiro é uma proposta inédita e o segundo uma continuação do trabalho realizado anteriormente. A proposta de emprego de redes neurais foi decorrente da complexidade da análise dos dados de ensaio e a ausência de regras explícitas tanto identificação do instante de entrada em regime quanto para avaliação das variáveis em regime transitório. São descritos no decorrer do trabalho: escolha das variáveis; treinamento, definição e avaliação dos sistemas neurais desenvolvidos. A redução obtida no tempo médio de ensaio foi significativa sem comprometer a confiabilidade dos resultados, abrindo novos caminhos para o emprego de recursos de inteligência artificial em ensaios de compressores

    Die Protokolle der Kreissynode Elberfeld von 1817 bis 1850

    No full text
    van Norden J. Die Protokolle der Kreissynode Elberfeld von 1817 bis 1850. Vol Band 148. Schriftenreihe des Vereins für Rheinische Kirchengeschichte: S. Flesch/D. Meyer/B. Magen; 2000

    Etüden-Sammlung für Violine. Studies and exercises for violin. Collection d'études pour violon, [by] Carl Flesch.

    No full text
    Sibley only owns v.2. -- Wilhelm Hansen Edition Nr. 2096. --- Notes in German, French and English by the author

    Entropy Generation Minimization Analysis of Solar Salt, Sodium, and Lead–Bismuth Eutectic as High Temperature Heat Transfer Fluids

    No full text
    The amount of entropy generation in heat transfer devices impacts their operation economy and should therefore be minimized during the design phase. Entropy generation also depends on the individual thermophysical properties of the heat transfer fluid (HTF). An entropy generation minimization analysis of three different liquid coolants, namely, solar salt (SS), sodium, and lead-bismuth eutectic (LBE) is thus performed for fully turbulent flow in a circular tube under circumferentially uniform heat flux by considering a heat rate, inlet and outlet temperatures and heat flux densities typical of a concentrated solar tower plant. The Reynolds number is determined at which the proper combination of Nusselt number and friction factor minimizing the entropy generation, and consequently the exergy loss, is obtained as well as the best thermodynamically performing coolant fluid over the operating range of Reynolds numbers. Sodium can operate at 60% lower entropy generation than solar salt while providing a smaller wall-to-bulk temperature difference. Despite its high thermal conductivity, LBE performs similarly to solar salt. However, it can be advantageous compared to solar salt if operated at higher temperatures that cannot be achieved by the latter due its thermal stability limit

    The readability of Australia’s taxation laws and supplemetary materials: an empirical investigation

    No full text
    Australian taxation law has been criticised for many years for its difficulty to read and understand. The Tax Law Improvement Project (TLIP) was established in December 1993 to rewrite in plain language Australia’s income tax legislation. The primary purpose of this study is to test empirically the effectiveness of attempts at simplifying the Income Tax Assessment Act 1936 as amended. The study utilises empirical measures in analysing the level of readability of Australia’s taxation laws. In doing so, it builds on earlier research, which applied similar methods in examining the New Zealand taxation simplification process. It was found that the sections of Income Tax Assessment Act 1997 sampled were slightly more readable than corresponding sections of Income Tax Assessment Act 1936 as amended, which is consistent with Wallschutzky’s (1995) findings. Nevertheless, the results fall well short of acceptable bench-marks, suggesting that the goal of simplification has not been achieved.

    Construction of a Test Facility for Demonstration of a Liquid Lead-bismuth-cooled 10 kW Thermal Receiver in a Solar Furnace Arrangement - SOMMER

    No full text
    Liquid metals have been proposed in the past as high temperature heat transfer media in concentrating solar power (CSP) systems. Until the mid 80s test facilities were operated with liquid sodium-cooled central receivers. After a period of reduced interest in that approach, several new efforts have been reported recently, particularly from the US, South Africa and Australia. In addition, several recent publications have highlighted the attractive properties of liquid metals for CSP applications. A newcontribution to this topic has been launched by Karlsruhe Institute of Technology (KIT) and the Solar Institute of the German Aerospace Center (DLR), combining their experience in CSP and liquid metal technology. The overall goals of this project are planning, design, construction and operation of a small concentrating solar power system in the 10 kW thermal range (named SOMMER) using liquid metal as heat transfer fluid for re-gaining operation experience and validating design methodology and providing a complete design concept for a large pilot CSP plant based on liquid metal technology, up to evaluation of O&M cost and levelized cost of electricity. This paper describes the current status of the work on the design and setup of SOMMER, the research goals of this facility, first results of numerical activities in view of the liquid metal cooled receiver design and the connection to the design activities for the pilot plant

    Desenvolvimento de modelos do comportamento metrólogico estático de instrumentos de medição

    No full text
    Dissertação (Mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico. Programa de Pós-Graduação em Metrologia Científica e IndustrialO presente trabalho teve como objetivo desenvolver um método para modelar o comportamento metrológico estático de instrumentos de medição. Esta atividade faz parte de um conjunto de trabalhos que vêm sendo executados junto ao Laboratório de Metrologia e Automatização da UFSC visando desenvolver um sistema de simulação de instrumentos de medição. A estrutura de um modelo geral proposto é formada pela característica de resposta nominal do instrumento e pelo encadeamento de módulos que contêm os modelos das características metrológicas estáticas geradas a partir de especificações de fabricantes. Para isso foi feito um estudo das principais características de instrumentos de medição, pesquisando-se literatura, normas, dados técnicos de fabricantes e folha de dados de instrumentos. De posse da sistematização desses dados, foi possível implementar o modelo de cada característica de forma modular, visando reduzir o esforço futuro para implementação do modelo de diferentes instrumentos. A partir do modelo geral de um instrumento, é possível criar instrumentos com valores específicos dentro dos limites especificados pelo fabricante. O processo de criação desses instrumentos utiliza a análise estatística dos valores especificados na folha de dados para cada parâmetro. Com o intuito de exemplificar a aplicação do modelo proposto, apresentou-se o modelo de quatro instrumentos: termistor, termorresistor, transdutor de pressão e amplificador de instrumentação. Esses modelos foram implementados utilizando-se a linguagem Labview
    corecore