1,720,958 research outputs found

    Going Beyond Counting First Authors in Author Co-citation Analysis

    Get PDF
    The present study examines one of the fundamental aspects of author co-citation analysis (ACA) - the way co-citation counts are defined. Co-citation counting provides the data on which all subsequent statistical analyses and mappings are based, and we compare ACA results based on two different types of co-citation counting - the traditional type that only counts the first one among a cited work's authors on the one hand and a non-traditional type that takes into account the first 5 authors of a cited work on the other hand. Results indicate that the picture produced through this non-traditional author co-citation counting contains more coherent author groups and is therefore considerably clearer. However, this picture represents fewer specialties in the research field being studied than that produced through the traditional first-author co-citation counting when the same number of top-ranked authors is selected and analyzed. Reasons for these effects are discussed

    Variations on the Author

    Get PDF
    “Variations on the Author” discusses two of Eduardo Coutinho’s recent films (Um Dia na Vida, from 2010, and Últimas Conversas, posthumously released in 2015) and their contribution to the general question of documentary authorship. The director’s filmography is characterized by a consistent yet self-effacing form of authorial self-inscription: Coutinho often features as an interviewer that rather than express opinions propels discourses; an interviewer that is good at listening. This mode of self-inscription characterizes him as an author who is not expressive but who is nonetheless markedly present on the screen. In Um Dia na Vida, however, Coutinho is completely absent form the image, while Últimas Conversas, on the contrary, includes a confessional prologue that moves the director from the margins to the center of his films. This article examines the ways in which these works stand out in the filmography of a director who offers new insights into the notion of cinematic authorship

    Appropriate Similarity Measures for Author Cocitation Analysis

    Get PDF
    We provide a number of new insights into the methodological discussion about author cocitation analysis. We first argue that the use of the Pearson correlation for measuring the similarity between authors’ cocitation profiles is not very satisfactory. We then discuss what kind of similarity measures may be used as an alternative to the Pearson correlation. We consider three similarity measures in particular. One is the well-known cosine. The other two similarity measures have not been used before in the bibliometric literature. Finally, we show by means of an example that our findings have a high practical relevance.information science;Pearson correlation;cosine;similarity measure;author cocitation analysis

    Dispelling the Myths Behind First-author Citation Counts

    Get PDF
    We conducted a full-scale evaluative citation analysis study of scholars in the XML research field to explore just how different from each other author rankings resulting from different citation counting methods actually are, and to demonstrate the capability of emerging data and tools on the Web in supporting more realistic citation counting methods. Our results contest some common arguments for the continued use of first-author citation counts in the evaluation of scholars, such as high correlations between author rankings by first-author citation counts and other citation counting methods, and high costs of using more realistic citation counting methods that are not well-supported by the ISI databases. It is argued that increasingly available digital full text research papers make it possible for citation analysis studies to go beyond what the ISI databases have directly supported and to employ more sophisticated methods

    An MMC-Based Temperature Control System for a Long-Term Data Collection

    No full text
    We developed a two-stage temperature control system for a long-term stable measurement of AMoRE neutrinoless double beta decay experiment using a dilution refrigerator. The first-stage control was made with a standard PID system using an AC bridge with a ruthenium oxide thermometer as the main thermometer of the mixing chamber plate. The second-stage control was obtained with a magnetic microcalorimeter (MMC) that is configured as a sensitive thermometer for a detector tower, the main experiment. Under single-stage temperature control on the temperature of the mixing chamber plate only with the RuO2 thermometer, the MMC recorded temperature stability of the detector plate of 9 mu K rms over 100 min. Under two-stage temperature control, with the first-stage of the mixing chamber plate at 11 mK via the RuO2 thermometer and the second-stage of the detector plate at 12 mK via the MMC, the MMC recorded a temperature stability of 0.5 mu K rms over 100 min. Moreover, the heat channels of the AMoRE experiment obtained considerable improvement in energy resolutions when switching from single-stage (RuO2) to two-stage (RuO2 + MMC) control.11Nsciescopu

    Author Index

    No full text
    Nao informado

    Low temperature property study of MMCs used for neutrinoless double beta decay

    No full text
    © 2021 IEEE. Personal use is permitted, but republication/redistribution requires IEEE permission. We present a comparison of the two types of metallic magnetic calorimeters (MMCs) developed for a large-scale neutrinoless double beta decay (0νββ) search experiment. As high resolution micro-calorimeters,MMCsemploy micro-fabricated superconducting circuits to measure the changes in magnetization of a paramagnetic sensor material. We constructed two alpha spectrometers with two MMC sensors made of Au:Er and Ag:Er (i.e., gold and silver alloys with small concentrations of Er). A piece of gold foil with a heat capacity comparable to that of 350 g CaMoO4 crystal near 10 mK was used as the absorber for each alpha spectrometer. These detector setups allowed us to investigate the temperature dependence of magnetization for the different sensor materials over a wide temperature range with various amounts of field current. The magnetizationmeasurements for both the Au:Er and Ag:Er sensors were in good agreement with calculations for field currents of up to 100 mA. Moreover, the measured and estimated pulse heights of alpha events agreed with each other, and were compared between the different sensor materials.We discuss howthe excess heat capacity fromthe nuclear spins in Au:Er influences the pulse size and shape in calorimetric detection. Moreover, we describe the benefit of using Ag:Er sensors in thermal calorimeters with large crystal absorbers in a 0νββ search experiment.11Nsciescopu

    A Lab-Scale Experiment for keV Sterile Neutrino Search

    No full text
    We developed a simple small-scale experiment to measure the beta decay spectrum of H-3. The aim of this research is to investigate the presence of sterile neutrinos in the keV region. Tritium nuclei were embedded in a 1x1x1 cm(3) LiF crystal from the Li-6(n,alpha)H-3 reaction. The energy of the beta electrons absorbed in the LiF crystal was measured with a magnetic microcalorimeter at 40 mK. We report a new method of sample preparation, experiments, and analysis of H-3 beta measurements. The spectrum of a 10-hour measurement agrees well with the expected spectrum of H-3 beta decay. The analysis results indicate that this method can be used to search for keV-scale sterile neutrinos.11Nsciescopu

    A Thermal Model of Low-Temperature Light Detectors for Neutrinoless Double Beta Decay Experiments

    No full text
    We report a detector model study for light detectors having Ge and Si wafers as absorbers with a metallic magnetic calorimeter (MMC) readout. The model explains the heat flow processes between the thermal components in the detector system, including athermal and thermal phonon transfers and electronic heat diffusion. The temperature dependence of the thermal conductance values was in good agreement with their expectations. The analysis also resulted in finding the characteristic time constants of the athermal phonons for direct absorption in the phonon collector film and for the downconversion to thermal phonons of the absorber wafers. It is a complete detector model to be applied for various detector variations such as the type and dimensions of the wafer absorber. © 2023, The Author(s).11Nsciescopu
    corecore