1,720,966 research outputs found
Glue or onyx: A guide to choice – tips and techniques
Glue and Onyx are two liquid embolic agents. They have different characteristics and applications, so it is essential to know how to choose between them. The main aims of this article are to describe the principles and features of these embolic agents, to highlight the advantages and limitations of both the materials, and to provide optimal indications of each agent during endovascular arterial embolization procedures
The treatment of post-partum bleeding with transcatheter arterial embolization
Background: Our aim was to assess the safety and efficacy of transcatheter embolization in the treatment of post-partum bleedings. Methods: In a single institution, the outcome of 15 patients who underwent transarterial embolization (TAE) for post-partum hemorrhages (PPH) were retrospectively reviewed. Eleven patients presented with hemodynamic instability requiring blood transfusion (73%) and four patients were hemodynamically stable (27%). Arterial embolization was performed with gelatin sponge, particles, and coils. Results: Mean follow-up time was 21.2 months (range 12–48 months). Technical success rate was 100%. The overall clinical success rate was 100%. No major complications that required intensive care treatment were registered during or after the procedures. No patient required emergency surgery and subsequent hysterectomy. During follow-up, four patients became pregnant after transcatheter arterial embolization and delivered full-term, healthy infants. Conclusions: TAE is a safe method that allows for the avoidance of surgery and hysterectomy for uncontrollable PPH; a future normal pregnancy after embolization may be hypothesized
Going Beyond Counting First Authors in Author Co-citation Analysis
The present study examines one of the fundamental aspects of author co-citation analysis (ACA) - the way co-citation
counts are defined. Co-citation counting provides the data on which all subsequent statistical analyses and mappings
are based, and we compare ACA results based on two different types of co-citation counting - the traditional type that
only counts the first one among a cited work's authors on the one hand and a non-traditional type that takes into
account the first 5 authors of a cited work on the other hand. Results indicate that the picture produced through this non-traditional author co-citation counting contains more coherent author groups and is therefore considerably clearer. However, this picture represents fewer specialties in the research field being studied than that produced through the traditional first-author co-citation counting when the same number of top-ranked authors is selected and analyzed. Reasons for these effects are discussed
Variations on the Author
“Variations on the Author” discusses two of Eduardo Coutinho’s recent films (Um Dia na Vida, from 2010, and Últimas Conversas, posthumously released in 2015) and their contribution to the general question of documentary authorship. The director’s filmography is characterized by a consistent yet self-effacing form of authorial self-inscription: Coutinho often features as an interviewer that rather than express opinions propels discourses; an interviewer that is good at listening. This mode of self-inscription characterizes him as an author who is not expressive but who is nonetheless markedly present on the screen. In Um Dia na Vida, however, Coutinho is completely absent form the image, while Últimas Conversas, on the contrary, includes a confessional prologue that moves the director from the margins to the center of his films. This article examines the ways in which these works stand out in the filmography of a director who offers new insights into the notion of cinematic authorship
Appropriate Similarity Measures for Author Cocitation Analysis
We provide a number of new insights into the methodological discussion about author cocitation analysis. We first argue that the use of the Pearson correlation for measuring the similarity between authors’ cocitation profiles is not very satisfactory. We then discuss what kind of similarity measures may be used as an alternative to the Pearson correlation. We consider three similarity measures in particular. One is the well-known cosine. The other two similarity measures have not been used before in the bibliometric literature. Finally, we show by means of an example that our findings have a high practical relevance.information science;Pearson correlation;cosine;similarity measure;author cocitation analysis
Follow-up of percutaneous microwave (MW) ablation of hepatic lesion: predictive value of CT at 24-h compared with CT at 1 month
To retrospectively assess the predictive value of the CT performed at 24 h, compared with the CT performed at 1 month, in the evaluation of the technical success of microwave (MW) ablation of hepatic lesions. In a single center, 50 patients with HCC underwent percutaneous MW ablation between November 2016 and March 2019. Each patient underwent a contrast-enhanced CT exam at 24 h and at 1 month after the procedure. For each patient, was assessed the presence or absence of residual disease, the appearance of a new lesion, complications, and the involvement of the hepatic capsule, both at 24-h and at 1 month. Overall correlation between residual disease, appearance of a new nodule and complications was also assessed. A total of 50 hepatic lesions were treated with US-guided MW ablation. Patients’ mean age was 70.9 years (range 28–87 years). Mean nodule diameter was 17.6 mm (range 7–35 mm). Contingency tables and the χ2 test showed a strong association when looking at capsule involvement (accuracy: 100%), residual disease (accuracy: 90%; p-value 0.003), and the appearance of a new HCC nodule (accuracy: 88%; p-value 0.007); regarding complications, the accuracy was 78% (p-value 0.014). Optimal correlation was reached in 62% of cases, moderate correlation in 26%, minimum correlation in 10% of cases; no cases of zero correlation were recorded. CT at 24 h and 1 month showed comparable efficacy in evaluating residual disease after MW thermal ablation of liver lesions. However, further studies are needed to assess which factors may cause false-negative results at the 24-h CT
Dispelling the Myths Behind First-author Citation Counts
We conducted a full-scale evaluative citation analysis study of scholars in the XML research field to explore just how different from each other author rankings resulting from different citation counting methods actually are, and to demonstrate the capability of emerging data and tools on the Web in supporting more realistic citation counting methods. Our results contest some common arguments for the continued
use of first-author citation counts in the evaluation of scholars, such as high correlations between author rankings by first-author citation counts and other citation
counting methods, and high costs of using more realistic citation counting methods that are not well-supported by the ISI databases. It is argued that increasingly available digital full text research papers make it possible for citation analysis studies to go beyond what the ISI databases have directly supported and to employ more
sophisticated methods
Percutaneous microwave thermosphere ablation of pancreatic tumours
Background: In oncologic field, thermo-ablative procedures have spread more and more. Percutaneous microwave ablation (MWA) showed same benefits and some advantages over radiofrequency ablation (RFA). To date, a disadvantage of both was the not totally predictable size and shape of ablation volume. The aim of this study was to assess feasibility and safety of MWA in nonresectable pancreatic head cancer using a new technology of MW with high power (100 W) and frequency of 2,450 MH. Methods: Five patients with pancreatic head cancer treated with percutaneous MWA under ultrasound guidance were retrospectively reviewed. Mean lesion diameter was 27.8 mm (range, 25-32 mm). Followup was performed by CT after 1, 3, 6 and, when possible, 12 months. The shape of the ablation volume was evaluated with multiplanar reformatting (MPR) using roundness index (RI): a value near 1 represents a more spherical ablation zone shape, and a value distant from 1 implies an oval configuration. Ablation and procedure times were registered, together with hospital stay. The feasibility, safety and quality of life (QoL) were reported. Results: The procedure was feasible in all patients (100%). A spherical shape of ablation zone was achieved in all cases (mean RI =0.97). Mean ablation and procedure time were respectively of 2.48 and 28 minutes. Mean hospital stay was 4 days. No major complications were observed. Minor complications resolved during the hospital stay. An improvement in QoL was observed in all patients despite a tendency to return to preoperative levels in the months following the procedure. Conclusions: Percutaneous MWA is a feasible and safe approach for the palliative treatment of advanced stage tumors of the head of the pancreas, despite its complex anatomic relations. The spherical shape of the ablation volume could be related with an improving of the effectiveness and safety
- …
