1,720,967 research outputs found
Plasma of argon cleaning treatment on implant abutments in periodontally healthy patients: Six years postloading results of a randomized controlled trial
The aim of this randomized, match-paired, triple-blinded, controlled clinical trial was to assess the 6-year radiographic changes around customized platform-switched abutments placed according to the one abutment-one time concept, with and without plasma of argon cleaning treatment. A total of 20 periodontally healthy patients received one maxillary implant between the premolars. Immediately before stage 2 surgery and abutment connection, patients were randomly assigned to the control (cleaning protocol by steam) or test group (plasma of argon treatment). Periapical standardized digital radiographs were taken at the time of crown connection (T0) and at 12 (T1), 24 (T2), 48 (T4), 60 (T5), and 72 months (T6) after the final restoration delivery. Primary outcome measures were the success rates of the implants and prostheses and the occurrence of any technical and biologic complications during the follow-up period. Secondary outcome measures were peri-implant marginal bone level changes, bleeding on probing, and plaque score. Two patients (one in test and one in control group) dropped out at the last follow-up. Neither implant nor prosthetic complications were detected in the analyzed patients of both groups during the 6-year follow-up examinations. Radiographic analysis revealed a statistically significant higher mean bone loss in the control group than in the test group at T2 (0.4 ± 0.28 mm; P = .018), T4 (0.52 ± 0.63 mm; P = .037), T5 (0.61 ± 0.70 mm; P = .038), and T6 (0.71 ± 0.66 mm; P = .011), but not at T1 (P = .131). From baseline to the 6-year follow-up, intragroup comparisons showed an absence of statistically significant difference in the test group (P = .08). Conversely, significant differences were found in the control group (P = .01). All implants demonstrated successful periodontal parameters, with no significant differences between groups. The results of this present study indicate that contaminant and bacterial removal from abutments in two-stage implants using plasma of argon could represent a positive strategy to minimize peri-implant bone resorption and longitudinally stabilize esthetic outcomes
Morphometric changes induced by cold argon plasma treatment on osteoblasts grown on different dental implant surfaces
Treatments for enhancing surface energy were studied in an effort to create a more favorable environment for cell adhesion. Cold argon plasma (CAP) is able to improve titanium-cell contact, producing hydrophilic surfaces with higher wettability. The aim of this in vitro study was to estimate the early cell morphology after CAP treatment of different commercially available titanium surfaces. Surface wettability was significantly augmented in all the treated samples. The authors investigated how CAP affected the behavior of osteoblasts by evaluating the cell morphology outcome. Cell surface areas differed in a statistically significant way when plasma-treated samples were compared to the untreated ones. The positive effect of CAP was shown on smooth, moderately rough, and rough implant surfaces
Mechanical outcomes, microleakage, and marginal accuracy at the implant-abutment interface of original versus nonoriginal implant abutments: A systematic review of in vitro studies
Purpose. Instead of original abutments, compatible abutments are often selected for financial reasons. The present study aimed to evaluate mechanical outcomes, microleakage, and marginal accuracy at the implant-abutment interface of original versus nonoriginal implant abutments. Study Selection. Search strategy encompassed literature from 1967 up to March 2017 to identify relevant studies meeting the inclusion criteria. The following electronic databases were consulted: PubMed database of the U.S. National Library of Medicine, Embase (Excerpta Medica dataBASE), and the Grey Literature Database (New York Academy of Medicine Grey Literature Report). Quality assessment of the full-text articles selected was performed. Abutments were classified in original (produced by the same implant manufacturer), nonoriginal certified (produced by a third-party milling center, certified by implant companies), and nonoriginal compatible (produced by a third-party milling center for similar connections). Results. A total of 16 articles fulfilled inclusion criteria and quality assessment and were selected for the qualitative analysis. All of the included studies were in vitro research with high or moderate risk of bias and reported data from 653 implant abutments. Original and nonoriginal certified abutments showed better results in terms of mechanical outcomes, microleakage, and marginal accuracy compared to nonoriginal compatible abutments. Conclusions. Following the clear warnings coming from the present systematic review, clinical suggestions regarding the effect of a nonoriginal abutment can be drawn. However, in vivo, long-term, randomized controlled trials are needed to provide definitive clinical conclusion about the long-term clinical outcomes of original and nonoriginal abutments
Going Beyond Counting First Authors in Author Co-citation Analysis
The present study examines one of the fundamental aspects of author co-citation analysis (ACA) - the way co-citation
counts are defined. Co-citation counting provides the data on which all subsequent statistical analyses and mappings
are based, and we compare ACA results based on two different types of co-citation counting - the traditional type that
only counts the first one among a cited work's authors on the one hand and a non-traditional type that takes into
account the first 5 authors of a cited work on the other hand. Results indicate that the picture produced through this non-traditional author co-citation counting contains more coherent author groups and is therefore considerably clearer. However, this picture represents fewer specialties in the research field being studied than that produced through the traditional first-author co-citation counting when the same number of top-ranked authors is selected and analyzed. Reasons for these effects are discussed
Variations on the Author
“Variations on the Author” discusses two of Eduardo Coutinho’s recent films (Um Dia na Vida, from 2010, and Últimas Conversas, posthumously released in 2015) and their contribution to the general question of documentary authorship. The director’s filmography is characterized by a consistent yet self-effacing form of authorial self-inscription: Coutinho often features as an interviewer that rather than express opinions propels discourses; an interviewer that is good at listening. This mode of self-inscription characterizes him as an author who is not expressive but who is nonetheless markedly present on the screen. In Um Dia na Vida, however, Coutinho is completely absent form the image, while Últimas Conversas, on the contrary, includes a confessional prologue that moves the director from the margins to the center of his films. This article examines the ways in which these works stand out in the filmography of a director who offers new insights into the notion of cinematic authorship
Appropriate Similarity Measures for Author Cocitation Analysis
We provide a number of new insights into the methodological discussion about author cocitation analysis. We first argue that the use of the Pearson correlation for measuring the similarity between authors’ cocitation profiles is not very satisfactory. We then discuss what kind of similarity measures may be used as an alternative to the Pearson correlation. We consider three similarity measures in particular. One is the well-known cosine. The other two similarity measures have not been used before in the bibliometric literature. Finally, we show by means of an example that our findings have a high practical relevance.information science;Pearson correlation;cosine;similarity measure;author cocitation analysis
Dispelling the Myths Behind First-author Citation Counts
We conducted a full-scale evaluative citation analysis study of scholars in the XML research field to explore just how different from each other author rankings resulting from different citation counting methods actually are, and to demonstrate the capability of emerging data and tools on the Web in supporting more realistic citation counting methods. Our results contest some common arguments for the continued
use of first-author citation counts in the evaluation of scholars, such as high correlations between author rankings by first-author citation counts and other citation
counting methods, and high costs of using more realistic citation counting methods that are not well-supported by the ISI databases. It is argued that increasingly available digital full text research papers make it possible for citation analysis studies to go beyond what the ISI databases have directly supported and to employ more
sophisticated methods
koamabayili/VECTRON-author-checklist: VECTRON author checklist
We have done our best to complete the author checklist relating to the use of animals in the hut study. Note that the objective for the hut study was to evaluate the IRS treatment applications for residual efficacy against Anopheles mosquitoes, including the local An. coluzzii mosquito population. Cows were only used to attract mosquitoes into the huts and no tests were carried out directly on the cows. The author checklist is intended for use with studies where experiments are carried out on animals, which is why we have had such difficulty in completing this for the hut study, as many of the questions do not relate to how the cows were used
- …
