1,721,021 research outputs found
LaBr<inf>3</inf>:Ce small FOV gamma camera with excellent energy resolution for multi-isotope imaging
Integrated ultrasound and gamma imaging probe for medical diagnosis
In the last few years, integrated multi-modality systems have been developed, aimed at improving the accuracy of medical diagnosis correlating information from different imaging techniques. In this contest, a novel dual modality probe is proposed, based on an ultrasound detector integrated with a small field of view single photon emission gamma camera. The probe, dedicated to visualize small organs or tissues located at short depths, performs dual modality images and permits to correlate morphological and functional information. The small field of view gamma camera consists of a continuous NaI:Tl scintillation crystal coupled with two multi-anode photomultiplier tubes. Both detectors were characterized in terms of position linearity and spatial resolution performances in order to guarantee the spatial correspondence between the ultrasound and the gamma images. Finally, dual-modality images of custom phantoms are obtained highlighting the good co-registration between ultrasound and gamma images, in terms of geometry and image processing, as a consequence of calibration procedures
Us Integrated Probe with a Micro Gamma Camera for Dual Modality Imaging in Medi- cal Diagnostics.
In the last few years, great attention has been pointed to multi-modality systems because of the growing request to gather as much information as possible from different types of diagnostic devices. In this contest, a novel dual-modality probe is presented, based on an ultrasound (US) detector integrated with a small field of view single photon emission gamma camera in order to obtain images reproducing perfectly the anatomical detail (US) where the functional one (gamma) is well defined and exactly positioned
Going Beyond Counting First Authors in Author Co-citation Analysis
The present study examines one of the fundamental aspects of author co-citation analysis (ACA) - the way co-citation
counts are defined. Co-citation counting provides the data on which all subsequent statistical analyses and mappings
are based, and we compare ACA results based on two different types of co-citation counting - the traditional type that
only counts the first one among a cited work's authors on the one hand and a non-traditional type that takes into
account the first 5 authors of a cited work on the other hand. Results indicate that the picture produced through this non-traditional author co-citation counting contains more coherent author groups and is therefore considerably clearer. However, this picture represents fewer specialties in the research field being studied than that produced through the traditional first-author co-citation counting when the same number of top-ranked authors is selected and analyzed. Reasons for these effects are discussed
Excellent pulse height uniformity response of a new LaBr3:Ce scintillation crystal for gamma ray imaging
Nuclear Medicine SPECT imaging is taking on new challenges, regarding the improvement of quality and contrast of images. In order to reach this goal, energy resolution and Compton rejection capability have to be enhanced. For detectors based on scintillation crystal, the choice of a scintillator with high light yield is suitable; recently one of the major candidates is Lanthanum Tri-Bromide (LaBr3:Ce), with its high 63,000 ph/MeV light yield. Unfortunately, LaBr3:Ce suffers size limitations due to the actual growth techniques (maximum 3 in. diameter) and has also elevated cost. For these reasons, great interest is shown on small field of view detectors based on LaBr3:Ce, thought for imaging of specific physiological process or organ. To improve energy resolution, continuous crystals are more appropriate instead than pixelated ones. Since in a continuous crystal a decrease in position linearity, due to the light reflections, is typically obtained at the edges, an absorbent treatment of surfaces is generally utilized for SPECT applications. On the other hand, light absorption causes a relevant degradation of local energy resolution and pulse height uniformity response, affecting local image contrast. In this work an analysis on a new continuous LaBr3:Ce scintillation crystal with size proper to a small field of view gamma imager but with reflective treatment of surfaces is presented. This leads up to outstanding overall and local energy resolution results and excellent pulse height uniformity response on the whole field of view. Furthermore, preliminary imaging results are satisfactory, compared to the ones from a scintillation crystal with absorbent edge
Variations on the Author
“Variations on the Author” discusses two of Eduardo Coutinho’s recent films (Um Dia na Vida, from 2010, and Últimas Conversas, posthumously released in 2015) and their contribution to the general question of documentary authorship. The director’s filmography is characterized by a consistent yet self-effacing form of authorial self-inscription: Coutinho often features as an interviewer that rather than express opinions propels discourses; an interviewer that is good at listening. This mode of self-inscription characterizes him as an author who is not expressive but who is nonetheless markedly present on the screen. In Um Dia na Vida, however, Coutinho is completely absent form the image, while Últimas Conversas, on the contrary, includes a confessional prologue that moves the director from the margins to the center of his films. This article examines the ways in which these works stand out in the filmography of a director who offers new insights into the notion of cinematic authorship
Appropriate Similarity Measures for Author Cocitation Analysis
We provide a number of new insights into the methodological discussion about author cocitation analysis. We first argue that the use of the Pearson correlation for measuring the similarity between authors’ cocitation profiles is not very satisfactory. We then discuss what kind of similarity measures may be used as an alternative to the Pearson correlation. We consider three similarity measures in particular. One is the well-known cosine. The other two similarity measures have not been used before in the bibliometric literature. Finally, we show by means of an example that our findings have a high practical relevance.information science;Pearson correlation;cosine;similarity measure;author cocitation analysis
Investigation of radiation detection properties of CRY-018 and CRY-019 scintillators for medical imaging
During the last years the research for new scintillation crystals has been crucial for the improvement of imaging performance in nuclear medicine applications. Crytur company has recently released two new scintillators named CRY-018 and CRY-019 which are non hygroscopic, have short decay time and low refraction index. They represent the ideal candidates to substitute NaI:Tl and BGO crystals in future PET ad SPECT applications. The purpose of this work is to characterize this unknown crystals, look for possible applications in imaging for nuclear medicine. The results of this work were compared with the results obtained with a LaBr3:ce scintillation crystal. This particular crystal is used as a comparison benchmark because of its strong linear pulse height uniformity response and high energy resolution. Measurements have been performed with a high count rate which is typical for medical applications. Irradiation of the crystals have been performed in three different geometries and in a photon energy range suitable with SPECT and PET applications. The experimental results identify the CRY-018 as an Yttrium and Silicon mixture and the CRY-019 with as Lutetium and Silicon one. Moreover a light yield of about 45% of LaBr3 one, was obtained for both the CRY-018 and CRY-019. This is one of the higher light yield between most of the scintillation crystals usually used in nuclear medicine. Both crystals are characterized by a non-proportionality in the pulse height linearity response. Energy resolutions of 7.4% for CRY-018 and 8.4% for CRY-019 at 661 keV, have been measured. The intrinsic component of the energy resolution has been esteemed for all three scintillators. An intrinsic detection efficiency of about 45% at 122 keV for CRY-018 and 14% at 661 keV for CRY-019 has been measured. Compared with LaBr3:Ce efficiency, which is highly deteriorated by the coating required by the hygroscopicity, CRY-018 and CRY-019 are really interesting considering that these two samples are only 6 mm thick. Crytur's crystals seem to be suitable for nuclear medicine applications. © 2016 IOP Publishing Ltd and Sissa Medialab srl
- …
