1,720,956 research outputs found
Comparison of breaking tests for the characterization of the interfacial strength of bilayer tablets
The bilayer tableting technology is gaining more acceptance in the drug industry, due to its ability to improve the drug delivery strategies. It is currently assessed by the European Pharmacopoeia, that the mechanical strength of tablets can be evaluated using a diametral breaking tester. This device applies a force diametrically, and records the tablet breaking point. This approach has been used to measure the structural integrity of single layer tablets as well as bilayer (and multi-layer) tablets. The latter ones, however, have a much complex structure. Therefore, testing a bilayer tablet with the currently used breaking test methodology might not be appropriate. The aim of this work was to compare results from several tests that have been proposed to quantify the interfacial strength of bilayer tablets. The obtained results would provide an indication on which tests are appropriate to evaluate the robustness of a bilayer tablet. Bilayer tablets were fabricated using a model formulation: Microcrystalline Cellulose (MCC) for the first layer, and spray dried lactose (SDLac) as second layer. Each set of tablets were tested using the following tests: Diametral Test, Shear Test and Indentation Test. The tablets were examined before and after the breaking test using Scanning Electron Microscopy (SEM). When a bilayer tablet was subjected to shearing or indentation, it showed signs of clear delamination. Differently, using the diametral test system, the tablets showed no clear difference, before and after the testing. However, when examining each layer via SEM, it was clear that a fracture occurred in the layer made of SDLac. Thus, the diametral test is a measure of the strength of one of the two layers and therefore it is not suited to test the mechanical strength of bilayer tablets
Development and validation of a DESI-HRMS/MS method for the fast profiling of esomeprazole and its metabolites in rat plasma: a pharmacokinetic study.
The advances in pharmaceutical development and drug discovery impose the availability of reliable high-throughput screening methods for the rapid evaluation of drug metabolism and pharmacokinetic (PK) in biological samples. Here, a desorption electrospray mass spectrometry (DESI-MS) method has been developed and validated for the PK profiling of esomeprazole and its metabolites (5-hydroxyomeprazole and omeprazole sulfone) in rat plasma. Rats were treated with an esomeprazole solution (2.5 mg/mL) for endovenous administration and the analyte levels were profiled over 2 h after liquid-liquid extraction from plasma. MS and tandem mass spectrometry (MS/MS) experiments were performed by using a DESI-LTQ-Orbitrap XL instrument and an on-spot fixed time analysis on PMMA surfaces. Validation was performed for the esomeprazole. The DESI-MS/MS method exhibited for the esomepazole excellent sensitivity (limit of detection (LOD)=60 ng/mL), linearity (0.2-20 μg/mL concentration range; y=23848(±361)X, n=15; r2=0.987) and precision (RSD0.05). The data achieved demonstrated that the DESI-MS method is suitable for sensitive and fast profiling of a drug and its metabolites at the therapeutic concentration levels. Copyright © 2015 John Wiley & Sons, Ltd
Combinazione di principi attivi in una singola forma farmaceutica per amministrazione orale: studio di formulazione e dei parametri critici di compressione
La tesi si divide in due parti: nella prima parte, condotta presso l`Universita` degli Studi di Parma, ci si e` focalizzati sulla formulazione di una compressa multistrato di Sucralfato e Ibuprofene Lisina. Si sono evidenziati aspetti formulativi e I parametri di compressione ideali al fine di realizzare una compressa. Nella seconda parte, effettuata presso l`universita` di Bordeaux, si sono studiati I parametri fisici di compressione. In particolare, uno studio dei test di rottura di una compressa multistate al fine di individuare il test adatto, quindi si e` messo in evidenza come la struttura dell`interfaccia influsca sulla resistenza meccanica della compressa. In ultimo, un Design of Experiment che include sia gli aspetti formulativi che i parametri di compressione ha portato a definire qual e` la condizione migliore per produrre e stoccare una compressa bistrato di Sucralfato e Ibuprofene lisina.The thesis is divided into two parts: the first part, conducted at University of Parma, is focused on the formulation of a multilayer tablet Sucralfate and Ibuprofen Lysine. The formulation aspects are highlighted as well as the compression parameters in order to manufacture this tablet. In the second part, done at University of Bordeaux, studied the physical compression parameters. In particular, a study of the breaking of a multilayer tablet in order to identify a suitable breaking test. In a second instance, it is highlighted how the structure of the interface influences on the mechanical strength of the tablet. At last, a design of experiments that includes both formulation aspects that the compression parameters has led to define what is the best condition to produce and store a bilayer of Sucralfate and Ibuprofen lysine
Going Beyond Counting First Authors in Author Co-citation Analysis
The present study examines one of the fundamental aspects of author co-citation analysis (ACA) - the way co-citation
counts are defined. Co-citation counting provides the data on which all subsequent statistical analyses and mappings
are based, and we compare ACA results based on two different types of co-citation counting - the traditional type that
only counts the first one among a cited work's authors on the one hand and a non-traditional type that takes into
account the first 5 authors of a cited work on the other hand. Results indicate that the picture produced through this non-traditional author co-citation counting contains more coherent author groups and is therefore considerably clearer. However, this picture represents fewer specialties in the research field being studied than that produced through the traditional first-author co-citation counting when the same number of top-ranked authors is selected and analyzed. Reasons for these effects are discussed
Variations on the Author
“Variations on the Author” discusses two of Eduardo Coutinho’s recent films (Um Dia na Vida, from 2010, and Últimas Conversas, posthumously released in 2015) and their contribution to the general question of documentary authorship. The director’s filmography is characterized by a consistent yet self-effacing form of authorial self-inscription: Coutinho often features as an interviewer that rather than express opinions propels discourses; an interviewer that is good at listening. This mode of self-inscription characterizes him as an author who is not expressive but who is nonetheless markedly present on the screen. In Um Dia na Vida, however, Coutinho is completely absent form the image, while Últimas Conversas, on the contrary, includes a confessional prologue that moves the director from the margins to the center of his films. This article examines the ways in which these works stand out in the filmography of a director who offers new insights into the notion of cinematic authorship
Appropriate Similarity Measures for Author Cocitation Analysis
We provide a number of new insights into the methodological discussion about author cocitation analysis. We first argue that the use of the Pearson correlation for measuring the similarity between authors’ cocitation profiles is not very satisfactory. We then discuss what kind of similarity measures may be used as an alternative to the Pearson correlation. We consider three similarity measures in particular. One is the well-known cosine. The other two similarity measures have not been used before in the bibliometric literature. Finally, we show by means of an example that our findings have a high practical relevance.information science;Pearson correlation;cosine;similarity measure;author cocitation analysis
Dispelling the Myths Behind First-author Citation Counts
We conducted a full-scale evaluative citation analysis study of scholars in the XML research field to explore just how different from each other author rankings resulting from different citation counting methods actually are, and to demonstrate the capability of emerging data and tools on the Web in supporting more realistic citation counting methods. Our results contest some common arguments for the continued
use of first-author citation counts in the evaluation of scholars, such as high correlations between author rankings by first-author citation counts and other citation
counting methods, and high costs of using more realistic citation counting methods that are not well-supported by the ISI databases. It is argued that increasingly available digital full text research papers make it possible for citation analysis studies to go beyond what the ISI databases have directly supported and to employ more
sophisticated methods
koamabayili/VECTRON-author-checklist: VECTRON author checklist
We have done our best to complete the author checklist relating to the use of animals in the hut study. Note that the objective for the hut study was to evaluate the IRS treatment applications for residual efficacy against Anopheles mosquitoes, including the local An. coluzzii mosquito population. Cows were only used to attract mosquitoes into the huts and no tests were carried out directly on the cows. The author checklist is intended for use with studies where experiments are carried out on animals, which is why we have had such difficulty in completing this for the hut study, as many of the questions do not relate to how the cows were used
- …
