69 research outputs found
Experimental device for obtaining calibration factor for the total count technique
Nuclear technologies have widely used on industry plants in order to help to solve troubles processes/design or just obtain information of them. The Total Count technique for flow measurement has as main advantages: being an absolute technique, because it is independent of additional devices readings unless the directly used for recording the radioactive cloud, requiring only a single detector to provide the final result; the independence of the internal volume of the transport duct, can be applied in the presence or absence of obstructions; no restriction as to the nature of the product or material to be conveyed; it is a noninvasive technique which allows real-time diagnostics. To use Total Count Technique, knowledge of a geometric calibration factor is required. Called Factor F, it is obtained in the laboratory using an experimental apparatus to faithfully reproduce the geometry of the detection system and the pipeline that being analyzed and using the same radiotracer, therefore, its value is constant for each specific measuring system under survey. This experimental apparatus for obtaining the factor F consisting by a pipe of 2 "PVC, which simulates a transmission line, where they were deposited 500 ml oil and the use of a specific pipette for use viscous fluids were added sequentially aliquots (50.00 ± 0.01) μl radiotracer (radionuclide photopeak energy of 198 Au 411.8 keV) and analyzing data obtained by three distinct detection systems composed of detectors NaI scintillators 1" x 1" and a data acquisition system
Calculation of dose due to total body irradiation treatment using anthropomorphic phantom in voxel
A irradiação de corpo de todo pode ser usada como tratamento pré condicionante para pacientes que serão submetidos ao transplante de medula óssea, com a finalidade de imunossupressão, ablação de medula e destruição de células malignas. É necessário determinar as doses referentes a essa deposição de energia, avaliando os órgãos e tecidos mais afetados. Além disso, comparar estes valores com os tipos de câncer mais incidentes de acordo com a estimativa do INCA para 2018. Também, percebe-se que existem fatores que influenciam a distribuição de doses, como a geometria de incidência e a distância entre a fonte e o paciente, que serão discutidos ao final. Para simular esse cenário, um modelo antropomórfico voxilizado masculino da ICRP 110, REX, foi submetido à irradiação de uma fonte pontual de Cobalto-60, não colimada e não blindada, para as duas geometrias de irradiação anteroposterior e pósteroanterior. O desenvolvimento se deu através do código computacional, MCNPx, que permite o cálculo da interação da radiação, no caso do trabalho são fótons, com a matéria. Os resultados obtidos contam com a dose equivalente nos órgãos e tecidos dispostos ao longo do corpo e com as doses efetivas, para os seis casos simulados. Por fim, conclui-se que a dose na superfície do paciente varia com o quadrado da distância, e que existe um padrão na distribuição de dose para cada geometria de incidência
Specific activity analysis of 40K, 226Ra, 228Ra and 232TH and determination of the risk of cancer due to the of infant formula
O conhecimento da radioatividade natural no homem e no seu ambiente é importante, uma vez que os radionuclídeos naturais são as principais fontes de exposição à radiação humana. É um fenômeno natural em que elementos radioativos e isótopos, que se encontram na natureza, são capazes de emitir radiações, como partículas alfa e beta, e radiação gama. Os nuclídeos radioativos presentes no ambiente natural entram no corpo humano principalmente através da ingestão de alimentos e água.
O presente trabalho apresenta valores de concentrações específicas dos radionuclídeos 226Ra, 228Ra e 40K em amostras de fórmulas infantis coletadas no município do Rio de Janeiro. A partir destes valores foi estimada a dose efetiva comprometida devida a ingestão das fórmulas infantis coletadas. O 40K teve atividade específica média de 202,24 ± 9,00Bq/Kg. Os outros radionuclídeos tiveram atividades específicas abaixo do limite de detecção pelo método utilizado. A dose efetiva anual devido ao 40K é de 260,90μSv, para crianças de 0 a 6 meses e de 136,46μSv para crianças de 6 a 24 meses.
Se tratando do risco de câncer esse presente trabalho calculou para essas amostras um valor médio de 1,99 E-4/ano, ou seja, a probabilidade de aumento do risco de câncer a dieta diária é de apenas 0,0199%
Estudo da viabilidade da técnica de radioscopia industrial em inspeção de soldas de recipientes transportáveis de gás liquefeito de petróleo
In the process of manufacturing transportable liquefied petroleum gas containers, according to the normative requirements, it is recommended to inspect the structural welds. Inspection using conventional radiography is, operationally, a limiting factor due to the time involved in the processing steps and the way records are stored. In this work the objective will be to compare the images obtained through the two techniques using a container of type P13 as object of study. The equipment used can operate in both modes allowing both tests to be performed. The criterion adopted in the inspections to evaluate the equivalence of the generated images is the number of the wire visible in the IQI (spatial resolution). It was possible to evidence the similarity of the images obtained through the radiographic film and the radioscopic image, with gain of speed in the inspection and sharpness. By introducing a later step of image processing an improvement in image quality was verified. It can be concluded that the technique is feasible, as it meets the requirements required by standard, obtaining greater performance in some aspects depending on the conditions of inspection and access to the area of interest.No processo de fabricação de recipientes transportáveis de gás liquefeito de petróleo, de acordo com os requisitos normativos, é recomendado inspeção das soldas estruturais. A inspeção utilizando a radiografia convencional é, operacionalmente, um fator limitante devido ao tempo de envolvimento nas etapas de processamento e o modo de arquivamento dos registros. Neste trabalho o objetivo será comparar as imagens obtidas através das duas técnicas utilizando um recipiente do tipo P13 como objeto de estudo. O equipamento utilizado é capaz de operar nos dois modos permitindo a realização de ambos ensaios. O critério adotado nas inspeções para avaliar a equivalência das imagens geradas é o número do fio visível no IQI (resolução espacial). Foi possível evidenciar a similaridade das imagens obtidas através do filme radiográfico e da imagem radioscópica, com ganho de velocidade na inspeção e nitidez. Ao introduzir uma etapa posterior de processamento de imagens foi verificado uma melhora na qualidade da imagem. Pode concluir-se que, a técnica é viável, pois atende aos requisitos exigidos por norma, obtendo performance maior em alguns aspectos dependendo das condições de inspeção e acesso a área de interesse
Study of the simulated CO60 source in MNCP applied to brachytherapy
A braquiterapia é um forma de tratamento de diversos tipos de tumores cancerígenos,
a qual insere dentro ou junto a área em questão uma fonte radioativa.
No mundo, as fontes são materiais radioativos variados, como Césio, Cobalto, Irídio,
Iodo, Paládio e Rutênio. Todavia, no Brasil, faz-se uso em especial do Irídio,
cuja meia vida é de apenas 74 dias. O presente trabalho propõe a simulação utilizando
Método de Monte Carlo, através do código de transporte de partículas, o
MCNP, para uma fonte de Cobalto-60, a qual possui maior meia vida comparado ao
Ir192, buscando validar o seu uso. Devido ao fato da não utilização deste material
no Brasil, foi necessário comparar os dados obtidos neste projeto com a literatura
internacional, em especial, americana. Os resultados obtidos mostrara-se estar de
acordo com o protocolo internacional do TG 43 e estudos internacionais
A prática do coronelismo em São João da Ponte (MG), no período de 1946-1996
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências Jurídicas.Este trabalho objetiva analisar o coronelismo como prática política atual e, para tanto, estabeleceu-se um recorte específico. Estuda-se a prática do coronelismo em São João da Ponte e se examina uma de suas características secundárias: o mandonismo de Dona Lulu , no período de 1946 a 1996. A maioria dos autores abordou tal fenômeno nas décadas de 50 a 80, indicando o declínio do coronelismo. A relevância desse estudo é comprovar que o coronelismo é uma prática atual. Pretende-se, também, estimular o conhecimento da prática política naquele município e levar a uma reflexão do fenômeno. Simão da Costa Campos, Olímpio da Costa Campos e Dona Lulu foram os representantes do coronelismo naquele município. A legitimidade do poder desses coronéis baseou-se em dois tipos de dominações weberianas: o poder dos dois primeiros fundamentou-se na tradição, já o poder de Dona Lulu, no carisma. A prática política no município passou por um viés maquiavélico. Como fatores preponderantes para a sobrevivência do coronelismo em São João da Ponte, apontam-se a debilidade financeira do município e a pobreza da população
Synthesis of iodine 123-labeled polymeric microspheres for the use of SPECT images in the embolization procedure
Vascular embolization is a clinical procedure widely used in the treatment of hypervascularized tumors. In this technique, dispersed polymer microspheres are injected through a catheter and reach the main blood vessel of the tumor, promoting an immediate obstruction. Consequently, the tumor region tends to atrophy or even die due to restricted nutrient supply. The vascular embolization procedure can be monitored by the Angiography technique; however, the images provided by this technique are not able to show the exact location of the blockade or the location of the particles. In this case, obtaining SPECT images may be an alternative, since this technique produces images of higher resolution, which would allow more precise tracking of the distribution of these particles in the body. The iodine 123 is a radioisotope widely used to obtain SPECT images and presents high in vivo stability when the radioiodine insertion occurs in aromatic rings. Therefore, the strategy used in this work was to obtain polymeric microspheres from the suspension polymerization of 4 vinylphenol with vinyl acetate for subsequent radioiodination of the same. This phenolic compound presents polymerization unsaturation and aromatic ring activated for radioiodination, which was performed using the iodo beads oxidizing agent. Prior to radioiodination, different percentages of 4 vinylphenol (0.10, 0.25 and 0.50 % w/w) were studied in order to select the composition that presented the most compatible characteristics for the use as an embolization agent. Mass polymerization, suspension polymerization, kinetic assays and the characterization of the synthesized polymeric materials were performed. The results showed that the desired copolymer was successfully obtained in the form of microspheres. Among the contents of 4 vinylphenol studied, microparticles synthesized with 0.10 % w/w of this comonomer exhibited the best properties to be used as an embolization agent and underwent radioiodination. Labeling results indicated a significant insertion of radioiodine in both PVAc and P(VAc co 4VPh) backbone.A embolização vascular é um procedimento clínico bastante utilizado no tratamento de tumores hipervascularizados. Nessa técnica, microesferas poliméricas dispersas são injetadas através de um cateter e alcançam o principal vaso sanguíneo do tumor, promovendo uma obstrução imediata. Consequentemente, a região tumoral tende a atrofiar ou até mesmo morrer, devido ao restrito fornecimento de nutrientes. O procedimento de embolização vascular pode ser monitorado pela técnica de Angiografia; no entanto, as imagens fornecidas por essa técnica não são capazes de mostrar o local exato do bloqueio nem a localização das partículas. Nesse caso, a obtenção de imagens SPECT pode constituir uma alternativa, pois essa técnica produz imagens de resolução superior, que permitiriam acompanhar, com maior precisão, a distribuição dessas partículas no organismo. O radioisótopo iodo 123 é largamente utilizado para a obtenção de imagens SPECT e apresenta alta estabilidade in vivo, quando a inserção do iodo ocorre em anéis aromáticos. Portanto, a estratégia utilizada neste trabalho consistiu em obter microesferas poliméricas a partir da polimerização em suspensão do 4 vinilfenol com o acetato de vinila para posterior radioiodação das mesmas. Este composto fenólico possui insaturação para polimerização e anel aromático ativado para radioiodação, que foi realizada utilizando-se o agente oxidante iodo beads. Previamente à radioiodação, diferentes porcentagens de 4 vinilfenol (0,10; 0,25 e 0,50 % m/m) foram estudadas de forma a selecionar a composição que apresentasse as características mais compatíveis ao uso como agente de embolização. Ensaios de polimerização em massa, polimerização em suspensão, ensaios de cinética e a caracterização dos materiais poliméricos sintetizados foram realizados. Os resultados mostraram que o copolímero desejado foi obtido com sucesso na forma de microesferas. Dentre os percentuais de 4 vinilfenol estudados, as micropartículas sintetizadas com 0,10 % m/m deste comonômero apresentaram as melhores características para serem usadas como agente de embolização e, portanto, foram submetidas à radioiodação. Os resultados da marcação indicaram uma inserção significativa de radioiodo nas matrizes poliméricas de PVAc e P(VAc co 4VF)
Desenvolvimento de um sistema de microtomografia de raios X de baixo custo para amostras de pequenas dimensões e baixas densidades
In this thesis, the development of a relatively inexpensive microtomographic system for the analysis of samples of small dimensions and low densities is presented. A flat panel detector originally developed for dental applications was used. The characterization process that allowed its implementation in a microtomographic system is detailed in the work. A study of the linear and volumetric magnifications of the system was carried out, allowing qualitative analysis to be obtained quantitative information of the sample investigated. The electromechanical control of object rotation and radiation exposure control was developed using the Arduino platform. A set of computational tools allowed the management of data acquisition and control of the entire system. As a final result, a functional system capable of implementing the whole microtomographic process is presented, from the acquisition of the two-dimensional projections to the three-dimensional visualization of the external and internal structures obtained in the microtomographic reconstruction process. Finally, results are obtained with samples such as a PVC tube, a small frog, a gecko and a human tooth where it was possible to visualize in detail its main characteristics and internal compositions.Apresenta-se, nesta tese, o desenvolvimento de um sistema microtomográfico de baixo custo relativo voltado para a análise de amostras de pequenas dimensões e baixas densidades. Foi utilizado um detector flat panel originalmente desenvolvido para aplicações odontológicas. O processo de caracterização que permitiu sua implementação em um sistema microtomográfico é detalhado no trabalho. Foi realizado um estudo das magnificações linear e volumétrica do sistema, possibilitando que além das análises qualitativas pudessem ser obtidas informações quantitativas da amostra investigada. O controle eletromecânico de rotação do objeto e de controle da exposição á radiação foi desenvolvido com a utilização da plataforma Arduino. Um conjunto de ferramentas computacionais permitiu o gerenciamento da aquisição dos dados e do controle de todo o sistema. Como resultado final, ´e apresentado um sistema funcional capaz de implementar todo o processo microfotográfico desde a aquisição das projeções bidimensionais até a visualização tridimensional das estruturas externas e internas obtidas no processo de reconstrução microfotográfica. Por fim, são apresentados resultados obtidos com amostras como um tubo de PVC, um pequeno sapo, uma lagartixa e um dente humano onde foi possível visualizar, com detalhes, as suas principais características e composições internas
Desenvolvimento de um sistema radiocromatográfico para avaliação do controle de qualidade radioquímico .
Neste trabalho foi desenvolvido um sistema radiocromatográfico com a finalidade de avaliar a pureza radioquímica, sendo um dos parâmetros determinantes de aprovação da qualidade do rádiofármaco iodeto de sódio (Na123 I Ultra Puro) produzido pelo Instituto de Engenharia Nuclear. O iodeto de sódio é um radiofármaco largamente usado nos exames para diagnosticar disfunção da tireóide. O sistema em questão,é composto por um motor de passo com a finalidade de movimentar uma mesa presa a um fuso. Sobre a mesa é colocado um papel específico para utilização em cromatografia contendo uma determinada concentração radioativa. A mesa, então, é movimentada sob um detector de radiação, e os dados de contagem provenientes do detector são transferidos para um software, que permite que estes dados sejam posteriormente analisados. Este sistema apresenta uma estrutura mecânica relativamente simples, um programa de computador de fácil utilização e componentes eletrônicos que podem ser encontrados sem dificuldades no mercado nacional, acarretando, com isso, um menor custo ao sistema sem perder a confiabilidade dos resultados obtidos
Caracterização de uma matriz detectora cintiladora para aquisição de imagem 2D da região folicular da Glândula Tireóide por emissão radioativa usando simulação Monte Carlo
The image acquisition methods applied to nuclear medicine and radiobiology are a valuable research study for determination of thyroid anatomy to seek disorders associated to follicular cells. The Monte Carlo (MC) simulation has also been used in problems related to radiation detection in order to map medical images since the improvement of data processing compatible with personnel computers (PC). This work presents an innovative study to find out the adequate scintillation inorganic detector array that could be coupled to a specific light photo sensor, a charge coupled device (CCD) through a fiber optic plate in order to map the follicles of thyroid gland. The goal is to choose the type of detector that fits the application suggested here with spatial resolution of 10 m and good detector efficiency. The methodology results are useful to
map a follicle image using gamma radiation emission. A source - detector simulation is performed by using a MCNP4B (Monte Carlo for Neutron Photon transport) general code considering different source energies, detector materials and geometries including pixel sizes and reflector types. The results demonstrate that by using MCNP4B code is possible to searching for useful parameters related to the systems used in nuclear medicine, specifically in radiobiology applied to endocrine physiology studies to acquiring thyroid follicles images.Os métodos de aquisição de imagem utilizados em medicina nuclear e na radiobiologia são valiosos na determinação da anatomia da glândula tireóide na busca de anormalidades associadas ao comportamento das células foliculares. A simulação baseada no método Monte Carlo (MC) também tem sido muito utilizada na solução de problemas relacionados à detecção da radiação visando o mapeamento de imagens médicas desde a evolução da capacidade de processamento dos computadores pessoais (PC). Este trabalho apresenta um estudo inovador para encontrar o tipo adequado de matriz cintiladora, que uma vez acoplada a um dispositivo CCD (Charge Coupled Device) através de uma placa de fibra ótica, pode ser aplicado no mapeamento de imagens de folículos da glândula tireóide. A metodologia utiliza a técnica de imageamento por emissão gama e a simulação MC, visando o desenvolvimento de um sistema capaz de obter uma imagem com resolução espacial de 10 m e boa eficiência do detector. A simulação do conjunto fonte-detector foi realizada por meio do programa MCNP4B (Monte Carlo para nêutron próton transporte) para diferentes energias, materiais detectores e geometrias, incluindo tamanho de “pixel” e tipos de materiais refletores. Os resultados alcançados mostram que utilizando o MCNP4B é possível estudar e avaliar parâmetros úteis relacionados aos sistemas utilizados em medicina nuclear, especificamente em radiobiologia aplicada a estudos da fisiologia endócrina no mapeamento de imagens de folículos tireoideanos
- …
