1,721,206 research outputs found

    Thrombectomy in Patients Ineligible for iv tPA (THRILL)

    No full text
    Rationale A relevant proportion of patients with acute ischemic stroke are ineligible for intravenous thrombolysis with recombinant tissue plasminogen activator. Mechanical thrombectomy offers a treatment alternative for these patients; however, only few data are available on its safety and efficacy. Aims and/or hypothesis The aim of this study was to compare safety and efficacy of stent retrievers as device class with best medical care alone in acute stroke patients with large intracranial vessel occlusion in the anterior circulation who are not eligible for intravenous thrombolysis with recombinant tissue plasminogen activator up to eight-hours of symptom onset. Design ‘Thrombectomy in patients ineligible for iv tPA’ is a prospective, open-label, blinded end-point, binational (Germany and Austria), two-arm, randomized, controlled, post-market study. Study outcome(s) Primary end-point is the modified Rankin Score shift analysis 90 days (±14) after stroke. Secondary end-points are excellent neurological outcomes (modified Rankin Score ≤ 1), good neurological outcomes (modified Rankin Score ≤ 2 or National Institutes of Health Stroke Scale improvement ≥ 10), difference between predicted infarct volume and actual core infarct volume (computed tomography or magnetic resonance imaging) at 30 (±6) h post-ictus, successful recanalization (thrombolysis in cerebral infarction score 2b or 3), functional health status 90 (±14) days after stroke (European Quality of Life-5 Dimensions) as well as common safety endpoints (adverse event, serious adverse event, symptomatic intracranial haemorrhage at 30 (±6) h, death, or dependency). Discussion Whether mechanical thrombectomy in patients with acute ischemic stroke who are not eligible for intravenous thrombolysis with recombinant tissue plasminogen activator improves clinical outcomes is unclear. ‘Thrombectomy in patients ineligible for iv tPA’ may change clinical practice by providing evidence of an effective and safe treatment for such patients

    MRI Gadolinium-based contrast media: meeting radiological, clinical, and environmental needs

    Full text link
    Gadolinium-based contrast agents (GBCAs) are routinely used in magnetic resonance imaging (MRI). They are essential for choosing the most appropriate medical or surgical strategy for patients with serious pathologies, particularly in oncologic, inflammatory, and cardiovascular diseases. However, GBCAs have been associated with an increased risk of nephrogenic systemic fibrosis in patients with renal failure, as well as the possibility of deposition in the brain, bones, and other organs, even in patients with normal renal function. Research is underway to reduce the quantity of gadolinium injected, without compromising image quality and diagnosis. The next generation of GBCAs will enable a reduction in the gadolinium dose administered. Gadopiclenol is the first of this new generation of GBCAs, with high relaxivity, thus having the potential to reduce the gadolinium dose while maintaining good in vivo stability due to its macrocyclic structure. High-stability and high-relaxivity GBCAs will be one of the solutions for reducing the dose of gadolinium to be administered in clinical practice, while the development of new technologies, including optimization of MRI acquisitions, new contrast mechanisms, and artificial intelligence may help reduce the need for GBCAs. Future solutions may involve a combination of next-generation GBCAs and image-processing techniques to optimize diagnosis and treatment planning while minimizing exposure to gadolinium

    Going Beyond Counting First Authors in Author Co-citation Analysis

    Full text link
    The present study examines one of the fundamental aspects of author co-citation analysis (ACA) - the way co-citation counts are defined. Co-citation counting provides the data on which all subsequent statistical analyses and mappings are based, and we compare ACA results based on two different types of co-citation counting - the traditional type that only counts the first one among a cited work's authors on the one hand and a non-traditional type that takes into account the first 5 authors of a cited work on the other hand. Results indicate that the picture produced through this non-traditional author co-citation counting contains more coherent author groups and is therefore considerably clearer. However, this picture represents fewer specialties in the research field being studied than that produced through the traditional first-author co-citation counting when the same number of top-ranked authors is selected and analyzed. Reasons for these effects are discussed

    Variations on the Author

    Full text link
    “Variations on the Author” discusses two of Eduardo Coutinho’s recent films (Um Dia na Vida, from 2010, and Últimas Conversas, posthumously released in 2015) and their contribution to the general question of documentary authorship. The director’s filmography is characterized by a consistent yet self-effacing form of authorial self-inscription: Coutinho often features as an interviewer that rather than express opinions propels discourses; an interviewer that is good at listening. This mode of self-inscription characterizes him as an author who is not expressive but who is nonetheless markedly present on the screen. In Um Dia na Vida, however, Coutinho is completely absent form the image, while Últimas Conversas, on the contrary, includes a confessional prologue that moves the director from the margins to the center of his films. This article examines the ways in which these works stand out in the filmography of a director who offers new insights into the notion of cinematic authorship

    Appropriate Similarity Measures for Author Cocitation Analysis

    Full text link
    We provide a number of new insights into the methodological discussion about author cocitation analysis. We first argue that the use of the Pearson correlation for measuring the similarity between authors’ cocitation profiles is not very satisfactory. We then discuss what kind of similarity measures may be used as an alternative to the Pearson correlation. We consider three similarity measures in particular. One is the well-known cosine. The other two similarity measures have not been used before in the bibliometric literature. Finally, we show by means of an example that our findings have a high practical relevance.information science;Pearson correlation;cosine;similarity measure;author cocitation analysis

    Dispelling the Myths Behind First-author Citation Counts

    Full text link
    We conducted a full-scale evaluative citation analysis study of scholars in the XML research field to explore just how different from each other author rankings resulting from different citation counting methods actually are, and to demonstrate the capability of emerging data and tools on the Web in supporting more realistic citation counting methods. Our results contest some common arguments for the continued use of first-author citation counts in the evaluation of scholars, such as high correlations between author rankings by first-author citation counts and other citation counting methods, and high costs of using more realistic citation counting methods that are not well-supported by the ISI databases. It is argued that increasingly available digital full text research papers make it possible for citation analysis studies to go beyond what the ISI databases have directly supported and to employ more sophisticated methods

    Author Index

    No full text
    Nao informado

    Gadofluorine M-enhanced magnetic resonance nerve imaging : comparison between acute inflammatory and chronic degenerative demyelination in rats

    No full text
    Nerve imaging by magnetic resonance imaging (MRI) is an emerging tool for the diagnostic work-up of patients with PNS disorders. We have recently shown that the experimental MR contrast agent gadofluorine M (Gf, Bayer Schering Pharma AG, Berlin) accumulates in nerves undergoing Wallerian degeneration and in areas of acute focal demyelination allowing in-vivo assessment of nerve pathology. The exact pathomechanism underlying Gf accumulation in peripheral nerve disorders is unknown so far. In the present study we compared nerve signal alterations on T2-w and Gf-enhanced T1-w MRI in two different models of acute inflammatory and chronic degenerative demyelination: experimental autoimmune neuritis (EAN) induced by immunization with PNS myelin and experimental Charcot-Marie-Tooth (CMT) disease in rats overexpressing the myelin protein PMP22. During the acute stage of inflammation and demyelination, strong Gf enhancement on T1-w MRI was seen in nerve roots and peripheral nerves in EAN, which resolved with completed remyelination. Similarly, Gf accumulation was seen in CMT rats during early stages with active demyelination at 6 weeks while at chronic stages (9 months) Gf enhancement decreased despite numerous demyelinated axons and onion bulb formation. At all disease stages no signal alterations were seen on T2-w MRI. In conclusion, our data show that the novel MR contrast agent Gf, but not Gadolinium (Gd)-DTPA, facilitates detection of ongoing demyelination by MR neurography independent from the underlying pathology. It appears that the extent of Gf enhancement depends on the acuity of demyelination and is probably related to a transient disturbance of the blood-nerve barrier. Clinical development of Gf may help to further improve the sensitivity of nerve lesion assessment by MRI in patients with peripheral neuropathies. (c) 2007 Elsevier Inc. All rights reserved
    corecore