3 research outputs found

    Skrining Senyawa Fitokimia Daun Kelakai (Stecnochlaena palustris) Asal Kalimantan Tengah Sebagai Alternatif Penyembuhan Luka

    No full text
    Latar Belakang: Tanaman Kelakai (Stecnolaena palustris) tanaman yang banyak ditenukan diseluruh wilayah Kalimantan Tengah. Habitat lahan basah, air tawar, dan semak belukar. Tanaman kelakai dikenal kalangan masyrakat adat kalimantan. Senyawa aktif daun Kelakai yang berperan dalam penyembuhan luka yaitu senyawa Flavonoid, fenol, tanin, Alkaloid sebagai penangkal bebas anti radikal. Tujuan Penelitian: Skrining dilakukan melihat potensi Daun Kelakai sebagai alternatif penyembuhan luka, dan digunakan dalam Pelayanan Kebidanan seperti Luka Perineum dengan jahitan, atau tanpa jahitan. Metode: Metode skrining fitokimia secara kualitatif reaksi warna. Hasil Penelitian: Tanaman Kelakai yang berasal dari Kalimantan Tengah Postive mengandung senyawa Alkaloid, Flavonoid, Saponin, Tanin. Kesimpulan: Senyawa aktif fitokimia yang terdapat di dalamnya membantu proses percepatan penyembuhan luka. Karena kemampuan antioksidan dan antibakteri pada kelakai yang terkandung dalamnya

    The design of digital instrument connected to android based smartphone to measure radiation

    No full text
    BackgroundIndonesian Government Regulation of 2007 on Safety and Health of Ionizing Radiation Utilization states that it is necessary to measure radiation exposure of X-ray machine for radiation protection for officers, patients and the public. At present there are very few devices that can measure the dose of radiation due to the limitation of radiation dose measurement device in health care institutions in Indonesia. Limitation of radiation dose measurement device is a quite alarming problem, so it becomes an obstacle in the implementation of radiation workers protection.Objective(s)The designing of a radiation measurement device using Geiger Muller detector, microcontroller and smartphone to display the result of radiation measurement.MethodsApplied study, true experiment study design, type of design was post test group only. The study consisted of 1 intervention group and 1 control group. The intervention group used a design of radiation measurement device while the control group used a standard radiation measurement device. Stability test was performed.ResultsThe stability test obtained Chi Square Test value (x2) of 2.6899, the measurement result was accepted because it was still in the range of 2.088 to 21,166.ConclusionA digital radiation measurement device that could be connected with android-based smartphone via Bluetooth connectivity was designed
    corecore