102,181 research outputs found
Human serum albumin adsorption onto a-SiC : H and a-C : H thin films deposited by plasma enhanced chemical vapor deposition
In the present paper, we report the study of the adsorption behavior of a model protein such as human serum albumin (HSA) onto surfaces of a-SiC:H and a-C:H thin films deposited by using the plasma-enhanced chemical vapor deposition (PECVD) technique. The surface composition and surface energy of the various substrates as well as the evaluation of the adsorbed amount of protein has been carried out by means of X-ray photoelectron spectroscopy (XPS) and contact angle measurements. It has been found that HSA tends to preferentially adsorb on Si-rich surfaces, as far as the relative amount of adsorbed HSA decreases with increasing Si-C concentration. Preliminary elements of mechanistic models are proposed for the correlation between chemical factors and the observed protein adsorption behavior. (C) 2002 Elsevier Science B.V. All rights reserved
Bibliographie Hilarion G. Petzold 1958 – 2009 mit Anhang als Einführung
Dieses Archiv enthält die Gesamtbibliographie der Werke des Autors nebst einiger Texte „Über H. G. Petzold“ im Schlussteil der Bibliographie sowie einen Anhang mit einer Einführung in die Architektur des Werkes in seinem wissenslogischen Aufbau als Ausarbeitung seines „Tree of Science Modells“ (2007).This archive contains the complete bibliography of the author and some texts about H. G. Petzold, moreover an epilogue with an introduction to the architecture of the works in its epistemological structure and composition and as an elaborations of Petzold’s „Tree of Science Modell (2007).https://www.fpi-publikation.de/polyloge/01-2009-petzold-h-g-gesamtbibliographie-h-g-petzold-1958-2009-updating-november2009/peerReviewedpublishedVersio
Dispelling the Myths Behind First-author Citation Counts
We conducted a full-scale evaluative citation analysis study of scholars in the XML research field to explore just how different from each other author rankings resulting from different citation counting methods actually are, and to demonstrate the capability of emerging data and tools on the Web in supporting more realistic citation counting methods. Our results contest some common arguments for the continued
use of first-author citation counts in the evaluation of scholars, such as high correlations between author rankings by first-author citation counts and other citation
counting methods, and high costs of using more realistic citation counting methods that are not well-supported by the ISI databases. It is argued that increasingly available digital full text research papers make it possible for citation analysis studies to go beyond what the ISI databases have directly supported and to employ more
sophisticated methods
Relevance of artefacts in 99mTc-MAA SPECT scans on pre-therapy patient-specific 90Y TARE internal dosimetry: A GATE Monte Carlo study
Objective. The direct Monte Carlo (MC) simulation of radiation transport exploiting morphological and functional tomographic imaging as input data is considered the gold standard for internal dosimetry in nuclear medicine, and it is increasingly used in studies regarding trans-arterial radio-embolization (TARE). However, artefacts affecting the functional scans, such as reconstruction artefacts and motion blurring, decrease the accuracy in defining the radionuclide distribution in the simulations and consequently lead to errors in absorbed dose estimations. In this study, the relevance of such artefacts in patient-specific three-dimensional MC dosimetry was investigated in three cases of 90Y TARE. Approach. The pre-therapy 99mTc MacroAggregate Albumin (Tc-MAA) SPECTs and CTs of patients were used as input for simulations performed with the GEANT4-based toolkit GATE. Several pre-simulation SPECT-masking techniques were implemented, with the aim of zeroing the decay probability in air, in lungs, or in the whole volume outside the liver. Main results. Increments in absorbed dose up to about +40% with respect to the native-SPECT simulations were found in liver-related volumes of interest (VOIs), depending on the masking procedure adopted. Regarding lungs-related VOIs, decrements in absorbed doses in right lung as high as -90% were retrieved. Significance. These results highlight the relevant influence of SPECT artefacts, if not properly treated, on dosimetric outcomes for 90Y TARE cases. Well-designed SPECT-masking techniques appear to be a promising way to correct for such misestimations
Recommended from our members
3346: Samuel G. Freedman, author, 2013
Photograph of author Samuel G. Freedman, at NT Daily Slash meeting in the Mayborn School of Journalism at UNT
Human Serum Albumin Adsorption Onto a-SiC:H And a-C:H Thin Films Deposited By Plasma Enhanced Chemical Vapour Deposition
- …
