1,726,320 research outputs found
5100: Pentagon
'5100: Pentagon' was first shown at Gwangju Biennale 2014.
The choreographed movements for the UK premiere of '5100: Pentagon' were inspired by collected archival images relating to the Gwangju uprising on 18 May 1980, and are set to an adapted version of the 1980s demonstration song, ‘A Song of May’. Each performance is constructed based on a web-tutorial accessed by anonymous groups of participants with no restrictions on age, gender and art experience. This project brings to light an unexplored period in history as an intensive moment, performed repetitively yet differently by voluntary participants in every new iteration.
'5100: Pentagon' is a project by Young In Hong in collaboration with choreographers Ann So-Hee Mannik Kristiansen and Sarah Louise Kristiansen
Validering av APTT i Sysmex CS-5100
Denne oppgaven tar for seg problemstillingen: Validering av aktivert partiell tromboplastintid (APTT) analysert i to Sysmex CS-5100 instrumenter. Oppgaven ble gitt av Avdeling for medisinsk biokjemi ved St. Olavs hospital. Det var ønskelig å undersøke om Sysmex CS-5100 oppfyller satte medisinske krav til analytisk kvalitet, basert på klinisk relevans og informasjon gitt fra produsent, for analysen APTT.
Hensikten med oppgaven var å undersøke om Sysmex CS-5100 oppfyller kravene for analytisk kvalitet, samt å vurdere om Sysmex CS-5100 gir samsvarende resultater og kan erstatte den nåværende metoden i ACL Top 750 for APTT.
For å undersøke den analytiske kvaliteten til APTT i Sysmex CS-5100, ble riktigheten samt den analytiske presisjonen i instrumentet sjekket. Den analytiske presisjonen ble betraktet ved å prøve metodens repeterbarhet og reproduserbarhet. Riktigheten ble vurdert, blant annet, ved å undersøke om interne- og eksterne kvalitetskontroller ga aksepterte verdier i forhold til akseptområde og fasitverdi oppgitt fra produsent. Riktigheten ble også undersøkt ved å sammenligne om de to Sysmex CS-5100 ga identisk resultat ved analysering av samme prøve, samt om Sysmex CS-5100 ga sammenlignbare resultater med nåværende instrument, ACL Top 750. Metodesammenligningen mellom Sysmex CS-5100 og ACL Top 750 la grunnlaget for å avgjøre om det måtte etableres nytt referanseområde for analysen.
Resultatene fra presisjonstestingen viser at Sysmex CS-5100 oppfyller krav satt til reproduserbarheten og repeterbarheten for APTT. Resultatene fra riktighetstesing av Sysmex CS-5100 viser at både de interne- og de eksterne kvalitetskontrollene ligger innenfor gitte akseptgrenser, samt at begge Sysmex CS-5100 instrumentene gir samsvarende analyseresultater i alle nivå. Metodesammenligning mellom Sysmex CS-5100 og ACL Top 750 viste at Sysmex CS-5100, systematisk måler 23,1% lavere verdier, sammenlignet med ACL Top 750, for APTT. Det ble dermed bestemt at det måtte etableres nytt referanseområde for analysen. Det nye referanseområdet samsvarte godt med referanseområde oppgitt av produsent av Sysmex CS-5100, samt med referanseområde for tilsvarende metode ved Haukeland Universitetssykehus.
Resultatene av undersøkelsene viste at den analytiske kvaliteten for APTT-analysen i Sysmex CS-5100, oppfyller kravene satt av medisinsk ansvarlig. Sysmex CS-5100 kan dermed erstatte ACL Top 750, og benyttes til analysering av APTT
Validering av APTT i Sysmex CS-5100
Denne oppgaven tar for seg problemstillingen: Validering av aktivert partiell tromboplastintid (APTT) analysert i to Sysmex CS-5100 instrumenter. Oppgaven ble gitt av Avdeling for medisinsk biokjemi ved St. Olavs hospital. Det var ønskelig å undersøke om Sysmex CS-5100 oppfyller satte medisinske krav til analytisk kvalitet, basert på klinisk relevans og informasjon gitt fra produsent, for analysen APTT.
Hensikten med oppgaven var å undersøke om Sysmex CS-5100 oppfyller kravene for analytisk kvalitet, samt å vurdere om Sysmex CS-5100 gir samsvarende resultater og kan erstatte den nåværende metoden i ACL Top 750 for APTT.
For å undersøke den analytiske kvaliteten til APTT i Sysmex CS-5100, ble riktigheten samt den analytiske presisjonen i instrumentet sjekket. Den analytiske presisjonen ble betraktet ved å prøve metodens repeterbarhet og reproduserbarhet. Riktigheten ble vurdert, blant annet, ved å undersøke om interne- og eksterne kvalitetskontroller ga aksepterte verdier i forhold til akseptområde og fasitverdi oppgitt fra produsent. Riktigheten ble også undersøkt ved å sammenligne om de to Sysmex CS-5100 ga identisk resultat ved analysering av samme prøve, samt om Sysmex CS-5100 ga sammenlignbare resultater med nåværende instrument, ACL Top 750. Metodesammenligningen mellom Sysmex CS-5100 og ACL Top 750 la grunnlaget for å avgjøre om det måtte etableres nytt referanseområde for analysen.
Resultatene fra presisjonstestingen viser at Sysmex CS-5100 oppfyller krav satt til reproduserbarheten og repeterbarheten for APTT. Resultatene fra riktighetstesing av Sysmex CS-5100 viser at både de interne- og de eksterne kvalitetskontrollene ligger innenfor gitte akseptgrenser, samt at begge Sysmex CS-5100 instrumentene gir samsvarende analyseresultater i alle nivå. Metodesammenligning mellom Sysmex CS-5100 og ACL Top 750 viste at Sysmex CS-5100, systematisk måler 23,1% lavere verdier, sammenlignet med ACL Top 750, for APTT. Det ble dermed bestemt at det måtte etableres nytt referanseområde for analysen. Det nye referanseområdet samsvarte godt med referanseområde oppgitt av produsent av Sysmex CS-5100, samt med referanseområde for tilsvarende metode ved Haukeland Universitetssykehus.
Resultatene av undersøkelsene viste at den analytiske kvaliteten for APTT-analysen i Sysmex CS-5100, oppfyller kravene satt av medisinsk ansvarlig. Sysmex CS-5100 kan dermed erstatte ACL Top 750, og benyttes til analysering av APTT.This thesis addresses the issue: Validation of activated partial thromboplastin time (APTT) in two Sysmex CS-5100 instruments. The assignment was set by the department of medical biochemistry at St Olav´s hospital. It was desirable to investigate whether Sysmex CS-5100 meets set medical requirements for analytical quality, based on clinical relevance and information provided by the manufacturer, for the APTT assay. The purpose of the thesis was to investigate whether Sysmex CS-5100 meets the requirement for analytical quality, and to assess whether Sysmex CS-5100 provides corresponding results and can replace the current method in ACL Top 750.
To examine the analytical quality of APTT in Sysmex CS-5100, the accuracy as well as the analytical precision of the instrument were tested. The analytical precision was assessed by testing the repeatability and reproducibility of the method. The correctness was assessed, in part, by examining whether internal- and external quality controls gave accepted values in relation to the areas of acceptance and the values stated by the manufacturer. The accuracy was also examined by comparing whether Sysmex CS-5100 gave results that compare with the current instrument, ACL Top 750. The method comparison between Sysmex CS-5100 and ACL Top 750 laid the foundation for making a decision on whether a new reference area should be established for the analysis.
The results from the precision testing show that Sysmex CS-5100 meets the requirements set for the reproducibility and repeatability of APTT. The result from correctness testing of Sysmex CS-5100 show that both the internal- and the external quality controls are within given acceptance limits, and that both Sysmex CS-5100 instruments give corresponding analysis results at all levels. The method comparison between Sysmex CS-5100 and ACL Top 750 showed that Sysmex CS-5100 systematically measures 23,1% lower values, compared to ACL Top 750, for APTT. It was then decided that a new reference area had to be established for the analysis. The new reference area corresponded well with the reference area stated by the manufacturer of Sysmex CS-5100, as well as with the reference area for a equivalent method at Haukeland University hospital.
The results of the testing showed that the analytical quality for analysis of APTT assay in Sysmex CS-5100, meets the set medical requirements for analytical quality and can replace ACL Top 750, and be used for analysis of APTT
SISTEM MONITORING IMPLEMENTASI SMART LIGHTS DIRUANGAN BERBASIS WIZNET 5100 ( IMPLEMENTATION MONITORING SYSTEM SMART LIGHTS IN A ROOM BASED WIZNET 5100 )
Jaringan telekomunikasi terus berkembang . Bahkan sekarang hamper seluruh orang di Dunia mempunyai akun twitter. Dengan melanjutkan hasil dari Proyek Smart Lights dengan maksud mengurangi penggunaan listrik dan juga bisa sebagai pemantauan didalam suatu rua ngan di rumah atau kantor perlu adanya sistem monitoring alat automasi nyala lampu ini dihubungkan ke arduino dan dari arduino akan mengirimk an data ke Wi znet 5100 dimana Wi znet 5100 ini interface ke sebuah twitter . Sehingga user dapat memantau keadaan rua ngan tanpa mendatangi ruangan tersebut tapi hanya melihat twitter user bisa mengetahui apakah diruangan teerdebut terdapat suatu gerakan atau tidak. Sistem monitoring yang dibuat oleh penulis menggunakan Wi znet 5100 sebagai interface antara arduino dengan twitter dan menggunakan base Wi znet 5100 untuk mengaktifkan seluruh fungsi dari Wi znet 5100 . Untuk menghubungkan antara Wi znet 5100 dengan twitter digunakan router TP LINK seri TL MR - 3020, dimana router tersebut ter dapat slot usb untuk modem gsm yang bias langsung terkoneksi dengan sebuah jaringan internet. Saat semua sudah terhubung maka proses monitoring pun bisa berjalan dengan baik. Setelah dilakukan pengujian, sistem monitoring ini menghasilkan output sebuah no tifikasi yang dikirim lewat akun twitter berdasarkan tanggal, jam, menit, dan detik. Dan system monitoring ini meggunakan inputan 5v agar system dapat berfungsi dengan baik
Long Non-Coding LEF1-AS1 Sponge miR-5100 Regulates Apoptosis and Autophagy in Gastric Cancer Cells via the miR-5100/DEK/AMPK-mTOR Axis
DEK and miR-5100 play critical roles in many steps of cancer initiation and progression and are directly or indirectly regulated by most promoters and repressors. LEF1-AS1 as a long non-coding RNA can regulate tumor development through sponge miRNA. The effect and regulatory mechanism of DEK on autophagy and apoptosis in gastric cancer (GC), and the role between miR-5100 and DEK or miR-5100 and LEF1-AS1 are still unclear. Our study found that DEK was highly expressed in gastric cancer tissues and cell lines, and knockdown of DEK inhibited the autophagy of cells, promoted apoptosis, and suppressed the malignant phenotype of gastric cancer. DEK regulates autophagy and apoptosis through the AMPK/mTOR signaling pathway. In addition, miR-5100 inhibits autophagy and promotes apoptosis in GC cells while LEF1-AS1 had the opposite effect. Studies have shown that miR-5100 acts by targeting the 3′UTR of DEK, and LEF1-AS1 regulates the expression of miR-5100 by sponging with mIR-5100. In conclusion, our results found that LEF1-AS1 and miR-5100 sponge function, and the miR-5100/DEK/AMPK/mTOR axis regulates autophagy and apoptosis in gastric cancer cells
Recommended from our members
H.R. 5100: Major Trade Legislation of the 102d Congress
The 102d Congress considered H.R. 5100, the Trade Expansion Act
of 1992, an omnibus trade bill covering a wide range of issues.
The bill became the legislative vehicle for a variety of pending
trade bills. H.R. 5100 was reported by the House Ways and Means
Committee on June 23, 1992, taken up by the House on July 8,1992,
amended, and passed. However, the bill received no action in the
Senate. H.R. 5100 included provisions pertaining to market access
for various U.S
Chicago, Rock Island & Pacific (RI) 5100
A photograph print showing the Chicago, Rock Island & Pacific (CRIP, RI, or ROCK) 5100, 4-8-4, head-on view, Kansas City, KS
Veto of R-252, H. 5100
This order by Governor Henry McMaster vetoes certain line items in R-252, H. 5100, the FY 2024-25 General Appropriations Act
Chicago, Rock Island & Pacific (RI) 5100
A photograph print showing the Chicago, Rock Island & Pacific (CRIP, RI, or ROCK) 5100, 4-8-4, Kansas City, KS. [see also 2008.008.5534
- …
