Jurnal Dampak
Not a member yet
    193 research outputs found

    Analisis Karbon Monoksida (CO) Menggunakan Metode Gaussian Plume di Persimpangan Margorejo Ahmad Yani Surabaya

    Get PDF
    Carbon monoxide is a pollutant that can interfere with human life and the environment. One of the sources of carbon monoxide pollutants comes from motor vehicle emissions. Heavy traffic can result in poor air quality. The city of Surabaya is the largest metropolitan city after Jakarta. One of the heavy traffic in the city of Surabaya is the Margorejo Ahmad Yani intersection, this intersection is the link between Surabaya and Sidoarjo. The purpose of this study is to determine the results of carbon monoxide in the field, predict the Gaussian Plume model, and calculate the results of field data validation and model data. Determination of the location of the sampling point is based on SNI 19-7119.6.9, 2005 section 6, so that a total of 6 sampling points can represent the intersection. The average yield of carbon monoxide in the field on Saturday, Sunday, and Monday in a row is 14,336 μg/m3, 13,615 μg/m3, 16,881 μg/m3. The distribution distance of the Gaussian model simulation on Saturday Morning; Afternoon; The afternoon in a row is 54 m; 64; 76 m, Sunday Morning; Afternoon; The afternoon in a row is 34 m; 53 m; 54 m, Monday Morning; Afternoon; The afternoon in a row is 62 m; 65 meters; 62 m. The results of field data validation and model data with the MAPE formula are 15.17%. Keywords: motor vehicles, carbon monoxide, gaussian  ABSTRAK Karbon monoksida merupakan polutan yang dapat mengganggu kehidupan manusia dan lingkungan. Salah satu sumber pencemar karbon monoksida berasal dari emisi kendaraan bermotor. Lalu lintas yang padat dapat mengakibatkan kualitas udara yang buruk. Kota Surabaya merupakan kota metropolitan terbesar setelah Jakarta. Salah satu lalu lintas yang padat di Kota Surabaya adalah simpang Margorejo Ahmad Yani, simpang ini merupakan penghubung antara Surabaya dengan Sidoarjo. Tujuan dari penelitian ini adalah untuk mengetahui hasil karbon monoksida di lapangan, memprediksi model Gaussian Plume, dan menghitung hasil validasi data lapangan dan data model. Penentuan lokasi titik pengambilan sampel didasarkan pada SNI 19-7119.6.9 tahun 2005 pasal 6, sehingga sebanyak 6 titik pengambilan sampel mewakili titik potong tersebut. Hasil rata-rata karbon monoksida di lapangan pada hari Sabtu, Minggu, dan Senin berturut-turut adalah 14.336 μg/m3, 13.615 μg/m3, 16.881 μg/m3. Jarak distribusi simulasi model Gaussian pada Sabtu Pagi; Sore; Sore berturut-turut adalah 54 m; 64; 76 m, Minggu Pagi; Sore; Sore berturut-turut adalah 34 m; 53 m; 54 m, Senin Pagi; Sore; Sore berturut-turut adalah 62 m; 65 meter; 62 m. Hasil validasi data lapangan dan data model dengan rumus MAPE sebesar 15,17%. Kata kunci: kendaraan bermotor, karbon monoksida, gaussian     Â

    Analisis Hubungan Sumber Pencemaran Udara Dalam Rumah Terhadap Penyakit ISPA Pada Balita

    Get PDF
    ARI is a disease with the highest mortality rate in the world, including in Indonesia. In Indonesia, ARI is still a public health problem due to high morbidity and mortality rates. As much as 15.4% of ARI cases attacked the under-five age group. In Jambi Province, ISPA is in the first rank of the ten main diseases from 2012-2019. This study aims to determine the relationship between sources of indoor air pollution and other risk factors that influence the occurrence of ARI in children under five. The method used in this research is cross-sectional. Test statistical analysis using the chi-square. Data collection was carried out by interviewing in the form of questionnaires and measuring using tools. The results showed that out of 108 children under five years old, 52 children had ISPA and 56 children had no ISPA. Based on the results of statistical tests, it shows that the variable smoking behavior, mosquito repellent, temperature, lighting, humidity, and parents' income have a relationship with the incidence of ARI in children under five years old, while the variables exclusive breastfeeding and immunization status statistically do not show a relationship with the incidence of ARI in children under five years old. Keywords: toddlers, acute respiratory infections (ARI), air pollution ABSTRAKISPA merupakan penyakit dengan angka kematian tertinggi di dunia, termasuk Indonesia. Di Indonesia, ISPA masih menjadi masalah kesehatan masyarakat karena tingginya angka kesakitan dan kematian. Sebanyak 15,4% kasus ISPA menyerang kelompok usia balita. Di Provinsi Jambi, ISPA menempati urutan pertama dari sepuluh penyakit utama dari tahun 2012-2019. Penelitian ini bertujuan untuk mengetahui hubungan antara sumber pencemaran udara dalam ruangan dengan faktor risiko lain yang mempengaruhi terjadinya ISPA pada balita. Metode yang digunakan dalam penelitian ini adalah cross sectional. Uji analisis statistik menggunakan chi-square. Pengumpulan data dilakukan dengan wawancara dalam bentuk angket dan pengukuran menggunakan alat bantu. Hasil penelitian menunjukkan bahwa dari 108 anak balita, 52 anak memiliki ISPA dan 56 anak tidak memiliki ISPA. Berdasarkan hasil uji statistik menunjukkan bahwa variabel perilaku merokok, pengusir nyamuk, suhu, pencahayaan, kelembaban, dan pendapatan orang tua memiliki hubungan dengan kejadian ISPA pada balita, sedangkan variabel pemberian ASI eksklusif dan status imunisasi secara statistik tidak menunjukkan hubungan dengan kejadian ISPA pada balita. Kata kunci: balita, infeksi saluran pernapasan akut (ISPA), pencemaran udar

    Studi Pengolahan Air Limbah Batik pada Skala Industri Rumah Tangga dan Usaha Kecil Menengah di Cirebon, Indonesia

    Get PDF
    Since the admission of batik as a world cultural heritage by the United Nations Educational, Scientific and Cultural Organization, the public interest in batik and the batik industry has been increasing. However, the problem arises when the development of the batik industry is not accompanied by batik wastewater treatment that fits the wastewater quality standard. Hence it causes environmental pollution, especially for the aquatic body. This paper discusses the conditions and awareness for batik wastewater treatment in the batik industry on household and small-to-medium scales in Plered District, Cirebon, Indonesia. It examines the pollutant load of batik wastewater in the area, the respondent's knowledge about wastewater processing systems, wastewater impact on the environment, and the need for education about batik wastewater treatment plants (WWTPs). The examination of wastewater samples showed that batik wastewater did not meet the waste quality standards and potentially harmed the environment. The respondents generally use synthetic dyes, and were unaware of its impact on the surrounding environment. Keyword: batik, WWTPs, batik production process, dye, wastewater impact  ABSTRAK Sejak ditetapkannya batik sebagai warisan budaya dunia oleh United Nations Educational, Scientific and Cultural Organization, minat masyarakat terhadap batik dan industri batik semakin meningkat. Namun permasalahan muncul ketika pengembangan industri batik tidak dibarengi dengan pengolahan air limbah batik yang sesuai dengan baku mutu air limbah. Oleh karena itu menyebabkan pencemaran lingkungan, terutama untuk badan air. Tulisan ini membahas tentang kondisi dan kesadaran pengolahan air limbah batik pada industri batik skala rumah tangga dan kecil-menengah di Kecamatan Plered, Cirebon, Indonesia. Kajian ini mengkaji beban polutan air limbah batik di wilayah tersebut, pengetahuan responden tentang sistem pengolahan air limbah, dampak air limbah terhadap lingkungan, dan perlunya penyuluhan tentang Instalasi Pengolahan Air Limbah (IPAL) batik. Pemeriksaan sampel air limbah menunjukkan bahwa air limbah batik tidak memenuhi baku mutu limbah dan berpotensi merusak lingkungan. Responden umumnya menggunakan pewarna sintetis, dan tidak mengetahui dampaknya terhadap lingkungan sekitar. Kata kunci: COD, elektrokoagulasi, elektroda aluminium, air limbah tahu, monopolar.     Â

    Efektivitas Metode Multi Soil Layering (MSL) dalam Penurunan Total Koliform Limbah Cair Domestik

    Get PDF
    This research employs Multi Soil Layering (MSL), an environmentally friendly technology, to remove coliform bacteria contaminants from wastewater using a novel alternative medium. The purpose of this study is to evaluate the efficacy of the MSL method employing bio rings in reducing pollutant parameters in domestic wastewater, particularly total coliform. This study utilized Hydraulic Loading Rate (HLR) variations of 23.80 L/m2/hour, 7.14 L/m2/hour, and 3.40 L/m2/hour, as well as Hydraulic Retention Time (HRT) variations of 4, 6, 8, 10, and 12 hours. The results of domestic wastewater treatment using the MSL method using HLR variations on total coliform from 1.89  105 MPN/100mL to 6.0  102 MPN/100mL, the total colony parameter from 5.95  106 CFU/mL to 3.6  105 CFU/mL, the chemical oxygen demand parameter value of 53 mg/L with an effectiveness of 98.6%, the total suspended solid parameter is valued at 25 mg/L with reduction effectiveness of 98.6% and the pH value changes to 7.3 at the HLR variation of 3.40 L/m2/hour. As for using the HRT variation for 12 hours the total coliform from 1.16  104 MPN/100mL to 9  102 MPN/100mL, the total colony parameter from 4.91  106 CFU/mL to 3.0  105 CFU/mL, the chemical oxygen demand parameter was 92 mg/L with its effectiveness 99%, the total suspended solid parameter is 87 mg/L with reduction effectiveness of 67% and the potential of hydrogen value changes to 7.6. Therefore, the MSL method employing bio rings can be used as a new option for domestic effluent treatment. Keywords: domestic wastewater, coliform total, Multi Soil Layering (MSL)  ABSTRAK Penelitian ini menggunakan Multi Soil Layering (MSL), sebuah teknologi ramah lingkungan, untuk menghilangkan kontaminan bakteri coliform dari air limbah menggunakan media alternatif baru. Tujuan dari penelitian ini adalah untuk mengevaluasi efikasi metode MSL dengan bioring dalam menurunkan parameter polutan dalam air limbah domestik, khususnya total coliform. Penelitian ini memanfaatkan variasi Hydraulic Loading Rate (HLR) 23,80 L/m2/jam, 7,14 L/m2/jam, dan 3,40 L/m2/jam, serta variasi Hydraulic Retention Time (HRT) 4, 6, 8, 10, dan 12 jam. Hasil pengolahan air limbah domestik dengan metode MSL menggunakan variasi HLR pada total coliform dari 1,89 × 105 MPN/100mL menjadi 6,0 × 102 MPN/100 mL, parameter total koloni dari 5,95 × 106 CFU/mL menjadi 3,6 × 105 CFU/mL, nilai parameter kebutuhan oksigen kimia 53 mg/L dengan efektivitas 98,6%, parameter total padatan tersuspensi senilai 25 mg/L dengan efektivitas reduksi 98,6% dan nilai pH berubah menjadi 7,3 pada variasi HLR 3,40 L/m2/jam. Sedangkan untuk menggunakan variasi HRT selama 12 jam total coliform dari 1,16 × 104 MPN/100mL menjadi 9 × 102 MPN/100mL, parameter total koloni dari 4,91 × 106 CFU/mL menjadi 3,0 × 105 CFU/mL, kebutuhan oksigen kimia parameter 92 mg/L dengan efektivitas 99%, parameter total padatan tersuspensi 87 mg/L dengan efektivitas reduksi 67% dan nilai potensial hidrogen berubah menjadi 7,6. Oleh karena itu, metode MSL yang menggunakan bio ring dapat digunakan sebagai pilihan baru untuk pengolahan limbah rumah tangga. Kata kunci: air limbah domestik, total koliform, Multi Soil Layering (MSL)     Â

    Pengembangan Jaringan Distribusi Air Minum di Bagian Selatan Kabupaten Banyuwangi

    Get PDF
    The Tegaldlimo branch of Banyuwangi water supply company serves 3 villages and 28 villages in the southern part of Banyuwangi district are not yet served by piped networks. This study aims to analyze the development of piped distribution networks in the short-term, medium-term term, and long-term Southern Banyuwangi Regency. The geometry method was carried out for population projection in 2042 that applied as the basis of average water demand. The calculation of water demand was simulated using EPANET 2.2, with maps of distribution pipelines to illustrate the hydraulic simulation of pipelines. The development of drinking water distribution networks in The Southern Banyuwangi Regency was divided into four stages according to the priority, namely Siliragung, Pesanggaran, Bangorejo, and Purwoharjo district. The development of the drinking pipeline network was carried out by using HDPE in diameters of 200, 180, 160, 140, 125, 110, 90, 75, and 63 mm and pump type of Grundfos UPS Series 200 with a maximum head of 18 m and a maximum flow of 70 cubic meter per hour. Keywords: development, SPAM, PUDAM  ABSTRAK PDAM Banyuwangi cabang Tegaldlimo melayani 3 desa dan 28 desa di Kabupaten Banyuwangi bagian selatan belum terlayani jaringan perpipaan. Penelitian ini bertujuan untuk menganalisis perkembangan jaringan distribusi perpipaan dalam jangka pendek, jangka menengah, dan jangka panjang di Kabupaten Banyuwangi Bagian Selatan. Metode geometri dilakukan untuk proyeksi penduduk tahun 2042 yang digunakan sebagai dasar kebutuhan air rata-rata. Perhitungan kebutuhan air disimulasikan menggunakan EPANET 2.2, dengan peta jaringan pipa distribusi untuk menggambarkan simulasi hidrolik jaringan pipa. Pembangunan jaringan distribusi air minum di Kabupaten Banyuwangi Selatan dibagi menjadi empat tahap sesuai prioritasnya, yaitu Kecamatan Siliragung, Pesanggaran, Bangorejo, dan Purwoharjo. Pengembangan jaringan pipa minum dilakukan dengan menggunakan HDPE diameter 200, 180, 160, 140, 125, 110, 90, 75 dan 63 mm dan pompa tipe Grundfos UPS Series 200 dengan head maksimum 18 m dan aliran maksimum 70 meter kubik per jam. Kata kunci: pengembangan, SPAM, PUDAM     Â

    Pengaruh Penggunaan Lahan Terhadap Debit Banjir Rancangan Di DAS Baubau

    Get PDF
    ABSTRACTThis research was conducted in the city of Baubau, Southeast Sulawesi Province, the location is focused on the area directly adjacent to the Baubau River which has a river length of 15,704 Km in the Baubau catchment with an area of 76,117 Km2. which empties into residential areas as areas where seasonal floods often occur. To reduce the risk of loss due to the impact of flooding flood control efforts are needed that can be carried out properly if the flood discharge design of the repeat design can be known. This study aims to analyze changes in land use against runoff coefficient with flood discharge design period of time in Baubau watershed. The analysis used is the descriptive analysis regarding the spatial distribution pattern of land use and its effect on the runoff coefficient in 2019. Then to get the discharge plan for the return time analysis was carried out using the Nakayasu Empirical method or the Synthetic Unit Hydrograph (HSS) with rainfall data for 2010 to 2019 obtained from the BMKG Betoambari station in Baubau City. From the results of the analysis, it will be obtained the flood discharge plans for the return period of 5, 10, 20, 25, 50, and 100 years.Keywords: Baubau watershed, flood discharge, hydrograph ABSTRAKPenelitian ini dilakukan di Kota Baubau Provinsi Sulawesi Tenggara, lokasi difokuskan pada wilayah yang berbatasan langsung dengan Sungai Baubau yang memiliki panjang sungai 15.704 Km di DAS Baubau dengan luas wilayah 76.117 Km2. yang bermuara di pemukiman penduduk sebagai daerah yang sering terjadi banjir musiman. Untuk mengurangi resiko kerugian akibat dampak banjir diperlukan upaya pengendalian banjir yang dapat dilakukan dengan baik jika debit banjir desain desain ulang dapat diketahui. Penelitian ini bertujuan untuk menganalisis perubahan penggunaan lahan terhadap koefisien limpasan dengan debit banjir periode rencana waktu di DAS Baubau. Analisis yang digunakan adalah analisis deskriptif mengenai pola sebaran spasial penggunaan lahan dan pengaruhnya terhadap koefisien limpasan Tahun 2019. Kemudian untuk mendapatkan debit rencana waktu ulang dilakukan analisis dengan menggunakan metode Empiris Nakayasu atau Hidrograf Satuan Sintetis (Synthetic Unit Hydrograph). HSS) dengan data curah hujan tahun 2010 sampai dengan tahun 2019 diperoleh dari stasiun BMKG Betoambari Kota Baubau. Dari hasil analisa tersebut akan diperoleh debit banjir rencana kala ulang 5, 10, 20, 25, 50 dan 100 tahun.Kata kunci: DAS Baubau, debit banjir, hidrogra

    Analisis Respon Siswa SMA di Kabupaten Situbondo terhadap Potensi Pemanfaatan Sampah Plastik sebagai Sumber Energi Listrik Rumahan

    Get PDF
    Plastic waste is one type of waste that is very difficult to decipher in the environment so as to reduce it and not pollute the environment many ways that have been done, such as 3R (Reduce, Reuse, Recycle) and currently many are utilizing it to become an alternative energy source. The purpose of writing this article is to find out the extent of the response of high school students in Situbondo district to the potential utilization of plastic waste as a source of home electrical energy according to the title of this article. The research method used is descriptive quantitative with data collection method using questionnaire method (questionnaire) through google form on high school students in Situbondo district. And the results from 87 high school students that plastic waste in Situbondo district is adequate to be used as a source of electrical energy and they are interested in learning it, but they are not sure if plastic waste as a source of small-scale electrical energy (home) can be applied in Situbondo in the future. Keywords: plastic waste, energy sources, home electricity ABSTRAK Sampah plastik merupakan salah satu jenis sampah yang sangat sulit diurai di lingkungan sehingga menguranginya dan tidak mencemari lingkungan banyak cara yang telah dilakukan, seperti 3R (Reduce, Reuse, Recycle) dan saat ini banyak yang memanfaatkannya menjadi sumber energi alternatif. Tujuan penulisan artikel ini adalah untuk mengetahui sejauh mana tanggapan siswa SMA di Kabupaten Situbondo terhadap potensi pemanfaatan sampah plastik sebagai sumber energi listrik rumah sesuai dengan judul artikel ini. Metode penelitian yang digunakan adalah deskriptif kuantitatif dengan metode pengumpulan data menggunakan metode kuesioner (angket) melalui google form kepada siswa SMA di Kabupaten Situbondo. Dan hasil dari 87 siswa SMA tersebut adalah sampah plastik di Kabupaten Situbondo cukup untuk digunakan sebagai sumber energi listrik dan mereka tertarik untuk mempelajarinya, tetapi mereka tidak yakin apakah sampah plastik sebagai sumber energi listrik skala kecil (rumah) dapat diterapkan di Situbondo di masa depan. Kata Kunci: sampah plastik, sumber energi, listrik rumahÂ

    Karakteristik Fisik dan Mekanik Bioplastik Berbahan Dasar Pati Limbah Kulit Pisang Raja Bulu (Musa paradisiaca L. var sapientum) dengan Variasi Jenis Plasticizer dan Kitosan

    Get PDF
    This study aims to determine the physical and mechanical characteristics of bioplastics made from Raja Bulu banana peel waste starch, which include tensile strength, elongation, thickness values, water absorption values, and how long this bioplastic can be decomposed. This research is experimentally based in a laboratory, starting with the manufacture of starch extraction, the process of making bioplastics, the testing process, and data analysis. Other additives used are plasticizers, which include glycerol and sorbitol, as well as the addition of chitosan. There are 2 variations in this study. The first variation is bioplastic with glycerol, sorbitol, and a mixture of glycerol + sorbitol without the addition of chitosan (A1, B1, and C1), while the second variation is bioplastic with glycerol, sorbitol plasticizer, and a mixture of glycerol + sorbitol with the addition of chitosan (A2, B2, and C2). The results of the tensile strength test for bioplastics made from banana peel waste starch ranged from 1.9 to 21.17 Mpa, with the highest tensile strength value being sample B2 and the lowest tensile strength value being sample A1. The resulting elongation value ranges from 12.62 to 64.22%, with the highest elongation value being sample A1 and the lowest elongation value being sample B2. The value of the resulting absorption ranges from 43.4–120.2% with the highest absorption value being sample B1 and the lowest absorption value being A2. The results of the biodegradability test show that bioplastics without chitosan can decompose for 14–15 days, while bioplastics with chitosan can decompose within 19–20 days. Keywords: bioplastic, plasticizer, chitosan, skin flour of Raja Bulu banana  ABSTRAK Penelitian ini bertujuan untuk mengetahui karakteristik fisik dan mekanik bioplastik berbahan baku pati kulit pisang Raja Bulu yang meliputi kuat tarik, kemuluran, nilai ketebalan, nilai daya serap air, dan berapa lama bioplastik ini dapat terurai. Penelitian ini berbasis eksperimen di laboratorium, dimulai dengan pembuatan ekstraksi pati, proses pembuatan bioplastik, proses pengujian, dan analisis data. Aditif lain yang digunakan adalah plasticizer, yang meliputi gliserol dan sorbitol, serta penambahan kitosan. Ada 2 variasi dalam penelitian ini. Variasi pertama adalah bioplastik dengan gliserol, sorbitol, dan campuran gliserol + sorbitol tanpa penambahan kitosan (A1, B1, dan C1), sedangkan variasi kedua adalah bioplastik dengan gliserol, plasticizer sorbitol, dan campuran gliserol + sorbitol. dengan penambahan kitosan (A2, B2, dan C2). Hasil uji kuat tarik bioplastik berbahan pati limbah kulit pisang berkisar antara 1,9 hingga 21,17 Mpa, dengan nilai kuat tarik tertinggi pada sampel B2 dan nilai kuat tarik terendah pada sampel A1. Nilai elongasi yang dihasilkan berkisar antara 12,62 hingga 64,22%, dengan nilai elongasi tertinggi pada sampel A1 dan nilai elongasi terendah pada sampel B2. Nilai serapan yang dihasilkan berkisar antara 43,4-120,2% dengan nilai serapan tertinggi adalah sampel B1 dan nilai serapan terendah adalah A2. Hasil uji biodegradabilitas menunjukkan bahwa bioplastik tanpa kitosan dapat terurai selama 14–15 hari, sedangkan bioplastik dengan kitosan dapat terurai dalam waktu 19–20 hari. Kata kunci: bioplastik, plasticizer, kitosan, pati kulit pisang raja bulu     Â

    Meninjau Efisiensi Penurunan Kadar CO2 oleh Living Moss Wall: Studi tentang Potensi dan Tantangan dalam Mengatasi Pencemaran Udara di dalam Ruangan

    Get PDF
    Indoor air pollution is dangerous for human health because almost 90% of human activity occurs indoors. An important factor when assessing indoor air quality is the concentration of carbon dioxide (CO2). Even at very low concentrations, it can have a marked effect on the health of those in it. The purpose of this study was to review the ability of moss used as a living wall to absorb CO2 and study its potential application in improving indoor air quality. In addition, this research will also identify challenges that may be faced in implementing living moss walls. This study used the true experimental method with a pretest and posttest control group observation design. The study was conducted by comparing CO2 levels from 2 white cigarette smoke with and without living moss wall in a prototype room made of glass with dimensions of 40 cm x 40 cm and 55 cm high.The research results show that the use of living moss wall as a solution to overcome indoor air pollution, especially CO2, cannot be separated from several obstacles that must be faced in its implementation. Living moss wall has a relatively low CO2 reduction efficiency value by using blumei’s moss (Macromitrium blumei). The use of a living moss wall must also pay attention to the suitability of the environment where it is installed so that the living moss wall can function properly.Keywords: Living moss wall, carbon dioxide (CO2), indoor air pollution  ABSTRAK Pencemaran udara dalam ruangan berbahaya bagi kesehatan manusia karena hampir 90% aktivitas manusia terjadi di dalam ruangan. Faktor penting dalam menilai kualitas udara dalam ruangan adalah konsentrasi karbon dioksida (CO2). Bahkan pada konsentrasi yang sangat rendah, CO2 dapat memiliki efek yang signifikan pada kesehatan orang yang berada di dalamnya. Tujuan dari penelitian ini adalah untuk mengevaluasi kemampuan lumut yang digunakan sebagai dinding hidup untuk menyerap CO2 dan mempelajari potensi aplikasinya dalam meningkatkan kualitas udara dalam ruangan. Selain itu, penelitian ini juga akan mengidentifikasi tantangan yang mungkin dihadapi dalam mengimplementasikan dinding lumut hidup. Penelitian ini menggunakan metode eksperimen sejati dengan desain observasi kelompok kontrol pretes dan postes. Penelitian ini dilakukan dengan membandingkan tingkat CO2 dari asap rokok putih dengan dan tanpa dinding lumut hidup dalam sebuah ruangan prototipe yang terbuat dari kaca dengan dimensi 40 cm x 40 cm dan tinggi 55 cm. Hasil penelitian menunjukkan bahwa penggunaan dinding lumut hidup sebagai solusi untuk mengatasi pencemaran udara dalam ruangan, terutama CO2, tidak dapat dipisahkan dari beberapa hambatan yang harus dihadapi dalam implementasinya. Dinding lumut hidup memiliki nilai efisiensi pengurangan CO2 yang relatif rendah dengan menggunakan lumut Macromitrium blumei. Penggunaan dinding lumut hidup juga harus memperhatikan kesesuaian lingkungan di mana dinding lumut hidup dipasang agar dapat berfungsi dengan baik.Kata Kunci: Living moss wall, karbon dioksida (CO2), pencemaran udara dalam ruangan     Â

    Identifikasi Pencemaran Limbah Di Sekitar TPA Antang Makassar Menggunakan Metode Geolistrik Resistivitas

    Get PDF
    The data presented in this paper are related to the characterization of a subsurface layer of TPA Antang, Makassar, South Sulawesi. The method used in this study is geo-electrical resistivity Wenner configuration by taking the data 3 lines in each region with lengths 150 m. Data processing used non-linear least square optimization with that of the 2D inversion software Res2Dinv. The results showed that the area was underlain by two layers of lithologic sections. The first layer with a resistivity value of 11.5 - 33.64 Ωm with a thickness ranging from 2-6 meters below the surface (original ground surface), was the sediment resulting from stockpiling dominated by silty sand sediment to sand based on field observation information. The second layer with a resistivity value of 3.02 - 11.5 Ωm with a depth ranging from 2 - 6 meters from the surface. The determination of this layer is based on information on well data and responses which indicate that this layer is swampy sediment, dominant sand ranging from sand alone to silty sand. The very small value of recessivity indicates that this layer is not compact sediment so the pore space between the grains was saturated. This layer is identified as a shallow aquifer. Based on the resistivity value, the fluid that filled this layer was divided into two types of fluids, fluids with a low resistivity value of 3.02 - 5.71 Ωm, it is assumed that the influence of leachate which is electrolytic makes it easy to flow electric current, and fluid with a resistivity value of 5.71 - 11.5 Ωm is a fluid that has not been contaminated with leachate. Keywords: Antang Landfill, geoelectric, groundwater, resistivity, waste ABSTRAKData yang disajikan dalam makalah ini terkait dengan karakterisasi lapisan bawah permukaan TPA Antang, Makassar, Sulawesi Selatan. Metode yang digunakan dalam penelitian ini adalah metode geolistrik resistivitas konfigurasi Wenner dengan mengambil data 3 jalur masing-masing daerah dengan panjang 150 m. Pemrosesan data menggunakan optimasi kuadrat terkecil non-linier dengan perangkat lunak inversi 2D Res2Dinv. Hasil penelitian menunjukkan bahwa daerah tersebut dilatarbelakangi oleh dua lapisan bagian litologi. Lapisan pertama dengan nilai resistivitas 11,5 - 33,64 m dengan ketebalan berkisar antara 2-6 meter di bawah permukaan (original ground surface), merupakan sedimen hasil penimbunan yang didominasi oleh sedimen pasir berlumpur hingga pasir berdasarkan informasi observasi lapangan. Lapisan kedua dengan nilai resistivitas 3,02 – 11,5 m dengan kedalaman berkisar antara 2 – 6 meter dari permukaan. Penentuan lapisan ini berdasarkan informasi data sumur dan respon yang menunjukkan bahwa lapisan ini merupakan sedimen berawa, dominan pasir mulai dari pasir saja sampai pasir berlumpur (silty sand). Nilai resesivitas yang sangat kecil menunjukkan lapisan ini merupakan sedimen yang tidak kompak sehingga ruang pori antar butir jenuh oleh air. Lapisan ini diidentifikasi sebagai akuifer dangkal. Berdasarkan nilai resistivitasnya, fluida yang mengisi lapisan ini terbagi menjadi dua jenis fluida yaitu fluida dengan nilai resistivitas rendah 3,02 – 5,71 m, diduga pengaruh lindi yang bersifat elektrolitik memudahkan aliran arus listrik dan fluida dengan nilai resistivitas 5,71 – 11,5 m merupakan fluida yang belum tercemar lindi. Kata kunci: TPA Antang, geolistrik, air tanah, resistivity, limba

    185

    full texts

    193

    metadata records
    Updated in last 30 days.
    Jurnal Dampak
    Access Repository Dashboard
    Do you manage Open Research Online? Become a CORE Member to access insider analytics, issue reports and manage access to outputs from your repository in the CORE Repository Dashboard! 👇