Physikalisch-Technische Bundesanstalt

Open Access Repository of the Physikalisch-Technische Bundesanstalt (PTB-OAR)
Not a member yet
    1101 research outputs found

    Liste der bei der PTB angezeigten und geprüften Schusswaffen gemäß § 9 Abs. 2 Nr. 1 Beschussgesetz (BeschG) bis lfd. Nr. 6099

    No full text
    Liste der bei der PTB angezeigten und geprüften Schusswaffen gemäß § 9 Abs. 2 Nr. 1 Beschussgesetz (BeschG

    D1: Inter-laboratory comparison report for low-level radionuclide detection by mass spectrometry

    No full text
    This report describes the preparation of a range of single and mixed radionuclide standards for an interlaboratory comparison exercise, focusing on comparing the capabilities of different mass spectrometers for low-level radioactivity measurement. Participating labs around Europe were asked to determine activity levels for a range of actinides (234U, 236U, 237Np, 239Pu, 240Pu, 241Am, NatU and 239/240Pu) and 90Sr. Standards were prepared from starting materials at NPL through a series of dilutions using a dedicated source preparation facility and characterised for their activity per unit mass and impurities using a combination of decay counting and mass spectrometric techniques. Standards were distributed to participating laboratories along with a form for submitting the results and details of the measurements made. There were delays in sending of the materials to the participating laboratories, however, results were submitted for all radionuclides using multiple techniques. This provides valuable information on the capabilities of mass spectrometry for low-level radionuclide measurement and can inform the development of future standards and comparison exercises

    LED-basierte Strahlungsquellen für die metrologische Anwendung in der Gonioreflektometrie

    No full text
    In den letzten Jahren kamen Leuchtdioden (LEDs) zunehmend in unzähligen Anwendungsgebieten zum Einsatz [1 bis 3]. Mit der kontinuierlichen Verbesserung ihrer Herstellungstechnologie, der Produktion neuer Halbleiterverbindungen, der Materialqualität, der chemischen Reinheit, der elektrischen Leitfähigkeit und der optischen Transparenz der verwendeten Optik werden die zugänglichen Spektralbereiche erweitert und die Wirkungsgrade der LEDs stetig gesteigert [4, 5]. Dadurch dringen LEDs in neue Anwendungsbereiche vor, wie z.B. die Ablösung konventioneller ultravioletter Strahlungsquellen zur Desinfektion von Wasser oder zur Aushärtung von Materialien [3, 4]. Damit steigt auch das Interesse an dem Einsatz von LEDs als moderne Strahlungsquellen für metrologische Anwendungen [5 bis 8]. Ihre Eignung als Strahlungsquelle für Reflexionsmessungen wird ausgiebig in dieser Arbeit durch den Aufbau, die Charakterisierung und die Integration eines LED Kugelstrahlers (LED Sphere Radiator, LED‑SR) in das robotergestützte Gonioreflektometer der PTB untersucht [9 bis 12]. Die wesentlichen Eigenschaften des LED‑SR wie seine spektrale Abdeckung, die zeitliche Stabilität und die Homogenität des Strahlungsfeldes werden vorgestellt. Zudem werden seine Einbindung in die Messapparatur und umfassende Vergleichsmessungen mit dem typischerweise verwendeten Halogen-Kugelstrahler (Halogen SR) gezeigt. Durch den konzipierten Spektralbereich und damit einhergehende höhere Strahlungsleistung des LED‑SR an der Grenze zwischen dem sichtbaren und dem UV A (360 nm – 430 nm) wird die Genauigkeit der Messung, genauer die Standardabweichung, in diesem Spektralbereich verbessert. Eine zugehörige detaillierte Messunsicherheitsbetrachtung für Messungen des absoluten spektralen Strahldichtefaktors nach dem „Guide to the expression of uncertainty in measurement (GUM)" des Bureau International des Poids et Mesures [13] wird dargestellt und exemplarisch anhand von drei Keramikproben präsentiert. Der Einfluss verschiedener systematischer und statistischer Unsicherheitsquellen und deren Beiträge werden ausführlich diskutiert. Neben der Verwendung des LED‑SR zur Messung des absoluten Strahldichtefaktors werden in der vorliegenden Arbeit die Fluoreszenzeigenschaften von diffus reflektierenden Proben sowie zuverlässige polarisationsaufgelöste Messungen bei Wellenlängen unterhalb von 430 nm betrachtet. Diese konnten erstmals aufgrund des günstigen Signal-Rausch-Verhältnisses des LED‑SR untersucht und erörtert werden. Es wird auf weiterführende Untersuchungen in der Verwendung des LED‑SR eingegangen, wie z. B. Messungen im gepulsten Betrieb sowie die Modularität und Erweiterung des LED‑SR in andere Spektralbereiche wird aufgezeigt. Zusammenfassend wird in dieser Arbeit ein detaillierter Überblick über den entwickelten LED‑SR als neue Strahlungsquelle für das Gonioreflektometer gegeben und dessen Einsatz ausgiebig beschrieben, geprüft und ausgewertet.PTB-Bericht Diss-2

    On the techniques for primary calibration of electronic radon detectors

    No full text
    Successful calibration of RadonEye +2 electronic radon detectors was performed at typical indoor activity concentrations using the facilities at LNHB and PTB. The calibration uncertainties using primary radon activity standards were: below 1.5 % at 300 Bq/m3, below 1.7 % at 130 Bq/m3 and below 2.5 % at 55 Bq/m3 (k = 1). When using the secondary standard AlphaGUARD, the uncertainty at 55 Bq/m3 was below 3.5 %. Maintaining stable activity concentrations proved crucial and appears to be the only feasible approach for calibrations below 100 Bq/m3. While calibration under exponentially decaying radon activity concentration remains useful for evaluating the devices’ linearity across a broad range, it proved unsuitable for calibration of user-grade monitors at low activities due to the high statistical variation in their signal. The linearity of RadonEye +2 was demonstrated in the range 50 Bq/m3 - 300 Bq/m3 and they will be utilized for the sensor networks developed within the RadonNET project. Dynamic background correction, applicable to non-spectrometric detectors, was applied based on the monitor\u27s exposure history. Furthermore, it was observed that the pulse-processing algorithm of RadonEyes +2 distorts the Poisson distribution of the signal, thereby increasing its variation. Potentially, lower measurement uncertainty could be achieved with electronic radon detectors that report the registered pulses and allow access to their processing algorithms

    Liste der von der PTB zugelassenen Schusswaffen gemäß § 8 Beschussgesetz (BeschG)

    No full text
    Liste der von der PTB zugelassenen Schusswaffen gemäß § 8 Beschussgesetz (BeschG

    Liste der von der PTB erteilten Baumusterprüfbescheinigungen nach Richtlinie 2006/42/EG

    No full text
    Liste der von der PTB erteilten Baumusterprüfbescheinigungen nach Richtlinie 2006/42/E

    Traceable low activity concentration calibration of radon detectors for climate change observation networks

    No full text
    Radon gas is the largest source of public expo-sure to naturally occurring radioactivity, and concentration maps based on atmospheric measurements aid developers in complying with EU Safety Standard Regulations. But radon can also be used as a tracer to evaluate dispersal models im-portant for supporting successful greenhouse gas (GHG) mit-igation strategies. That is why reliable measurements of low-level radon activity concentrations, such as those found in the environment (< 20 Bq∙m-3), are important for both radiation protection and climate research. Despite the enormous changes in radon metrology that have occurred in recent years activity concentrations below 100 Bq∙m-3 had not been sub-ject to metrological research so far. This evokes new chal-lenges which are the development of traceable methods and robust technology for measurements of environmental low-level radon activity concentrations and radon fluxes from the soil. Both are important to derive information on greenhouse gas fluxes in the environment and therefore are important for planning the reduction strategy. In the framework of the EMPIR project 19ENV01 trac-eRadon [1], stable atmospheres with low-level activity con-centrations of radon have been produced to enable calibration of radon detectors capable of measuring these environmental activity concentrations. The required traceability of the cali-bration at very low activity concentrations, was not possible in the past. To achieve this goal, low activity sources of radium have been produced [2,3] with different methods and different characteristics. Sources down to few Bq of 226Ra have been developed and characterized leading to uncertainties as low as 2 % (k=1), even in case of the lowest activity sources. Ad-ditionally, sources with medium and high activities were pro-duced, with advanced production methods like ion implanta-tion of mass separated 226Ra in different target materials. As an outcome, for the first-time traceable methods for measuring low-level atmospheric radon activity concentra-tions in the range of 1 Bq·m-3 to 50 Bq·m-3 with uncertainties below 5 % (k=1) are now available. To compare the perfor-mance of the sources in application, e.g., to establish a refer-ence atmosphere, a calibration exercise with two highly sen-sitive, large volume, low radon activity concentration detec-tors of different design and principle was carried out at the PTB. The details of the calibration procedure of these unique prototypes of detectors are presented. The results of the characterization of the detectors are discussed and as a con-clusion new developments in the field of radon metrology are presented. The project 19ENV01 traceRadon received funding from the EMPIR programme co-financed by the Participating States and from the European Union's Horizon 2020 research and innovation programme

    Radon sensor networks for large buildings: balancing the trade-off between energy efficiency and health

    No full text
    Radon 222 is a radioactive noble gas that is formed in the decay of the primordial 238U decay chain, with an average abundance of 3 parts per million (3 g ⋅ t-1) in the earth\u27s crust. Since radon is the only noble gas in the decay chain, it has with its half live T12 = 3.8232(8) d, the ability to emanate from the ground or building materials and to interfere with the biosphere. Taking into account Directive 2013/59/Euratom, the EURAMET EPM project RadonNET was founded to find a trade-off between energy efficiency and health effects by means of measurements with small uncertainties. With this in mind, an pulse ionization chamber for the time-resolved measurement of radon activity at low concentrations is described here. The solution shown is characterized by low sensitivity to room and impact noise. Experimental investigations show the properties of the pulse ionization chamber under various conditions, particularly with regard to its use in sensor networks in larger buildings or future cities

    Liste der bei der PTB angezeigten Marken und Herstellerzeichen gemäß § 24 Abs. 6 Waffengesetz (WaffG)

    No full text
    Liste der bei der PTB angezeigten Marken und Herstellerzeichen gemäß § 24 Abs. 6 Waffengesetz (WaffG

    Technische Kompetenzbereiche für Vergleichsmessungen : Richtlinie DKD-R 0-1

    No full text
    Das Ziel dieser Richtlinie ist die Definition von technischen Kompetenzbereichen (auf der Grundlage des Dokuments EA-4/18 G:2021 Guidance on the level and frequency of proficiency testing participation) und Verfahren für die Sicherung der Validität von Ergebnissen von Kalibrierlaboratorien im Zusammenhang mit ihrer Akkreditierung. Diese Definitionen stellen die Mindestanforderungen an den Umfang und die Zeitintervalle für entsprechende Kompetenznachweise dar und können auf der Basis risikobasierter Ansätze sachgerecht modifiziert werden (ILAC-P9:01/2024 ILAC Policy for Proficiency Testing and/or Interlaboratory comparisons other than Proficiency Testing). Im Regelfall erfolgt die Sicherung der Validität von Ergebnissen gemäß DIN EN ISO/IEC 17025:2018 Kap. 7.7 durch regelmäßige Vergleichsmessungen mit Laboratorien gleicher bzw. höherer Kompetenz oder durch erfolgreiche Teilnahme an verfügbaren Eignungsprüfungen (EP). In Fällen, in denen sinnvolle Vergleiche bzw. EP nicht möglich oder verfügbar sind müssen andere Überprüfungsmethoden der technischen Kompetenz in diesen Bereichen vereinbart werden. Gleichwertige Regelungen sollten angewendet werden für die Bewertung von Anbietern von EP (DIN EN ISO/IEC 17043: 2023, DIN ISO 13528:2020) für Kalibrierlaboratorien

    0

    full texts

    1,101

    metadata records
    Updated in last 30 days.
    Open Access Repository of the Physikalisch-Technische Bundesanstalt (PTB-OAR)
    Access Repository Dashboard
    Do you manage Open Research Online? Become a CORE Member to access insider analytics, issue reports and manage access to outputs from your repository in the CORE Repository Dashboard! 👇