Gazi University Dspace
Not a member yet
26981 research outputs found
Sort by
Safety, efficacy and patient-reported outcomes with trifluridine/tipiracil in pretreated metastatic colorectal cancer: results of the PRECONNECT study
Background In RECOURSE (, trifluridine/tipiracil significantly improved
overall survival and progression-free survival (PFS) versus placebo in
patients with pretreated metastatic colorectal cancer (mCRC). PRECONNECT
was designed to further characterise safety and clinical use of
trifluridine/tipiracil.
Methods In this ongoing, international, multicentre, open-label trial,
patients with pretreated mCRC received oral trifluridine/tipiracil 35
mg/m(2) twice daily on days 1-5 and 8-12 of each 28-day cycle. The
primary endpoint was safety; secondary endpoints included PFS and
quality of life (QoL).
Results 793 patients (median age 62 years) from 13 countries received
trifluridine/tipiracil for a median of 2.84 months (IQR 2.64). Adverse
events (AEs) were experienced by 96.7\%; the most common (>= 20\% of
patients) were neutropaenia, asthenia/fatigue, nausea, anaemia and
diarrhoea. Grade >= 3 AEs occurred in 73.9\% of patients, with the most
common being neutropaenia (39.1\% of patients), anaemia (9.8\%) and
asthenia/fatigue (5.0\%). Median PFS was 2.8 months (95\% CI 2.7 to
2.9). Median time to Eastern Cooperative Oncology Group performance
status deterioration (>= 2) was 8.9 months (range 0.03-14.72). There was
no clinically relevant change from baseline in QoL.
Conclusions PRECONNECT showed consistent results with the previously
demonstrated safety and efficacy profile of trifluridine/tipiracil, with
no new safety concerns identified. QoL was maintained during treatment
A Technical Modification to Reduce Potential Contamination in Transperineal Prostate Fusion Biopsy
Assessment of the Bearing Capacity of Foundations on Rock Masses Subjected to Seismic and Seepage Loads
It is usual to adopt the seismic force acting as an additional body
force, employing the pseudo-static hypothesis, when considering
earthquakes in the estimation of the bearing capacity of foundations. A
similar approach in seepage studies can be applied for the pore
pressure's consideration as an external force. In the present study, the
bearing capacity of shallow foundations on rock masses considering the
presence of the pseudo-static load was developed by applying an
analytical solution for the Modified Hoek and Brown failure criterion.
Calculations were performed adopting various inclinations of the load
and the slope on the edge of the foundation, as well as different values
of the vertical and horizontal components of the pseudo-static load. The
results are presented in the form of charts to allow an affordable and
immediate practical application for footing problems in the event of
seismic loads or seepages. Finally, and to validate the analytical
solution presented, a numerical study was developed applying the finite
difference method to estimate the bearing capacity of a shallow
foundation on a rock mass considering the presence of an additional
horizontal force that could be caused by an earthquake or a seepage
Relationship Between Teachers' Philosophical Beliefs About Education and Their Perceptions of School Climate
Optımızatıon Of Reactıve Power Dıspatch Problem In Power Systems Usıng New Heurıstıc Algorıthms
Bu tez çalışmasında, güç sistemlerinin ekonomik ve güvenilir işletilmesi için sistem
operatörlerinin sistematik bir mantıkla karar vermelerini sağlayan en önemli araçlardan biri
olan Optimum Reaktif Güç Dağıtımı (ORGD) probleminin çözümlenmesi üzerine analizler
gerçekleştirilmiştir. Öncelikle ORGD problemine optimum çözüm bulunması amacıyla
kolay uygulanabilir olması ve herhangi bir parametre değerleri belirlemeye ihtiyaç
duymaması gibi önemli avantajlara sahip olan Simbiyotik Organizmalar Arama (SOA)
Algoritması uygulanmıştır. Bununla beraber SOA’nın ORGD gibi birçok bölgesel
optimumu olan ve konveks olmayan problemlerin çözümünde yetersiz kalabildiği tespit
edilmiştir. Bu tespitler ışığında, SOA algoritması modifiye edilerek tek amaçlı ORGD
(TAORGD) ve çok amaçlı ORGD (ÇAORGD) optimizasyon problemleri için sırasıyla
Adaptif Kaotik Simbiyotik Organizmalar Arama (AKSOA) ve Çok Amaçlı Adaptif Kaotik
Simbiyotik Organizmalar Arama (ÇAAKSOA) adlı yeni algoritmalar geliştirilmiştir.
Tasarlanan algoritmalar kullanılarak farklı büyüklükteki şebekelerde TAORGD ve
ÇAORGD kapsamında aktif güç kaybı, toplam gerilim sapması ve statik gerilim kararlılığı
iyileştirilmiştir. TAORGD analiz sonuçlarına göre, AKSOA algoritmasının klasik SOA
algoritmasının yanı sıra, literatürdeki güncel çalışmalarda önerilen birçok algoritmadan daha
iyi olduğu görülmüştür. ÇAORGD analizlerine göre ise; ÇAAKSOA algoritmasıyla elde
edilen en iyi uzlaşık çözümlerin MOSOS algoritmasıyla elde edilen en iyi uzlaşık
çözümlerden daha iyi olduğu anlaşılmıştır. Yapılan simülasyon çalışmalarıyla, önerilen yeni
algoritmaların ORGD problemi üzerinde etkinliği doğrulanmış, ayrıca diğer kısıtlı
optimizasyon problemlerinin çözümünde de tercih edilebilir bir algoritma olacağını
göstermiştir.In this thesis, analyzes are conducted on the solution of Optimum Reactive Power Dispatch
(ORPD) problem, which is one of the most important tools that enable system operators to
make a decision with a systematic logic for the economical and reliable operation of power
systems. To find an optimal solution to ORPD problem, Symbiotic Organisms Search (SOS)
algorithm, which has important advantages such as easy application and no need to
determine any parameter values, is firstly applied. However, it has been found that SOS may
be unsatisfactory in solving non-convex problems involving multiple local optima. In the
light of these findings, new algorithms called Adaptive Chaotic SOS (A-CSOS) and Multi
Objective ACSOS (MOACSOS) are developed by modifying the SOS for single objective
ORPD (SORPD) and multi objective ORPD (MORPD), respectively. By using the designed
algorithms, active power loss, total voltage deviation and voltage stability have been
improved within the scope of SORGD and MORPD in different test systems. According to
the results of SORPD analysis, A-CSOS has been found to be better than the standard SOS,
as well as many algorithms proposed in current studies in the literature. According to
MORPD analysis, it has been understood that the best compromised solutions obtained with
the MOACSOS are better than Multi Objective SOS. The efficiency of the proposed
algorithms on the ORPD problem has been confirmed with the simulation studies, and it has
also been shown that it will be a preferable algorithm for the solution of other constrained
optimization problem
Energy Effıcıent Placement Of Vırtual Securıty Functıons: Method Proposals And Applıcatıon
Yazılım Tanımlı Ağlar (Software Defined Networking - SDN) ve Ağ Fonksiyonlarını Sanallaştırma (Network Functions Virtualization – NFV) teknolojilerinin kullanıldığı ortamlarda güvenlik; saldırı tespit sistemi ve güvenlik duvarı gibi fonksiyonların sanallaştırılması ve birer yazılım haline getirilerek genel amaçlı sunucular üzerinde çalıştırılması ile sağlanmaktadır. Bir ağda, sanal güvenlik fonksiyonları (virtual security functions - VSF) tarafından işlenen trafik akışlarının farklı güvenlik gereksinimleri olabilmektedir. Öte yandan her ağda, güvenlik sağlanırken göz önünde bulundurulması gereken ve ağın ihtiyaçlarına göre farklılık gösteren bir takım operasyonel amaçlar (maliyetin ez aza indirgenmesi, yük dengeleme yapılması vb.) vardır. Bu nedenle, ağın güvenlik gereksinimlerini ve operasyonel amaçlarını göz önünde bulundurarak VSF’lerin yerleştirilmesi ele alınması gereken önemli bir problemdir. Bu doğrultuda, tez kapsamında yapılan çalışmalar üç başlık altında toplanmıştır. İlk çalışmada, literatürde ilk defa bir taksonomi geliştirilmiş ve literatürdeki mevcut VSF yerleştirme çözümleri bu taksonomi ışığında sekiz boyutta sınıflandırılarak tartışılmıştır. İkinci çalışmada, literatürde ilk defa, trafik akışı bazında güvenlik gereksinimleri göz önünde bulundurularak enerji etkin bir şekilde sanal ağ güvenliği fonksiyonlarının yerleştirilmesi ve trafiğin ihtiyaçları doğrultusunda bu fonksiyonlar üzerinden yönlendirilmesi problemi modellenmiş ve çözülmüştür. Bu amaçla, bir Tam Sayılı Doğrusal Programlama (Integer Linear Programming – ILP) modeli geliştirilmiş ve bu modelin ölçeklenebilirlik sorununu çözmek için enerji tüketimini en aza indirgeyen çözümleri kısa sürede üreten yeni bir sezgisel algoritma önerilmiştir. Son olarak üçüncü çalışmada, geliştirilen yaklaşımın yazılım tanımlı ağ altyapısında uygulanabilirliğini göstermek için sezgisel algoritmanın aldığı kararlar doğrultusunda ağa gelen trafik akışlarını yönlendiren SDN kontrolcüsü geliştirilmiştir. Sonuç olarak, geliştirilen yöntemlerin, enerji tüketimini %48’e kadar azalttığı ve geliştirilen SDN kontrolcüsünün ağa gelen trafiği toplam bant genişliği, uçtan uca gecikme, paket kayıp oranı ve jitter gibi hizmet kalitesi parametreleri açısından etkin bir şekilde yönlendirebildiği görülmüştürIn Software Defined Networking (SDN) and Network Functions Virtualization (NFV) enabled environments, network security is provided by virtualizing security functions such as intrusion detection system and deep packet inspection etc., and deploying them on general-purpose servers as software. The traffic handled by virtual security functions (VSF) may have different security requirements. On the other hand, there are some operational objectives that differ according to the needs of the network such as minimizing cost and load balancing. Therefore, the issue of placing VSFs considering both security requirements and operational objectives is an important research challenge. In this regard, the studies conducted in the scope of this thesis is grouped under three parts. In the first study, a novel thematic taxonomy for classifying current VSF placement solutions is developed for the first time in the literature. State-of-the-art studies are reviewed and categorized based upon the eight dimensions of the developed taxonomy. In the second study, the problem of (i) VSF placement with the objective of minimizing energy consumption while meeting security requirements of the traffic at the flow-level, (ii) and routing flows through the VSFs according to their needs is defined and modelled for the first time in the literature. To this end, an Integer Linear Programming (ILP) model is developed to minimize server energy consumption. In addition, a novel heuristic algorithm that produces solutions minimizing energy consumption within practical time limits is proposed to solve the scalability issue of the ILP model for larger scale network instances. Finally in the third study, an SDN controller that forwards network traffic according to the results of the proposed energy-efficient VSF placement heuristic is developed in order to demonstrate the practicality of our placement approach in SDN infrastructures. As a result, it is concluded that the developed methods can reduce energy consumption by up to 48%, and network traffic can be effectively routed in terms of the QoS parameters including throughput, end-to-end latency, packet loss rate, and jitte