Informes de la Construcción (E-Journal)
Not a member yet
    5825 research outputs found

    Editorial

    Get PDF

    Fractura del hormigón en régimen no lineal. Intentos para medir la energía de fractura GF

    Get PDF
    This contribution has two objectives: To introduce a non linear model for concrete fracture and to analyze test methods for measuring GF. The apparent reason for the inapplicability in many cases of linear elastic fracture mechanics to cracking in concrete lies in the nature of the process zone. To overcome this difficulty a cohesive crack model is introduced and applied to derive a size effect law, similar to Bazant's. Despite the overwhelming number of fracture experiments, there is still lack of knowledge about the basic parameter GF. This paper aims to analyze the theoretical basis of such methods as well as to discuss test results obtained by the authors according to RILEM and Bazant proposals.El propósito de este artículo es doble: presentar un modelo de fractura no lineal y analizar la metodología seguida para medir GF. El principal inconveniente para aplicar la mecánica de la fractura en régimen elástico y lineal al hormigón, reside en la naturaleza de la zona de fractura. Para superar esta dificultad se ha desarrollado el modelo de la fisura con cohesión, que se presenta y analiza en este trabajo. Este modelo se ha utilizado para deducir la influencia del tamaño en la carga de rotura, habiéndose obtenido resultados similares a los de Bazant. A pesar de los numerosos experimentos sobre fractura de hormigones todavía no está claro cómo medir GF. En este artículo se analizan los fundamentos teóricos de estos métodos y se hace un estudio crítico de los resultados obtenidos por los autores siguiendo los métodos propuestos por la RILEM y por Bazant

    Iglesia parroquial de la virgen de la consolación en Sassuolo de Modena (Italia)

    Get PDF
    The church, sited north of the town in a magnificent ancient garden park, consist of a whole uncovered reinforced concrete structure. The covering, independent with respect to the inner spaces, has a square plan with a central opening. Four circular columns support the four main roof beams upon which are set, at short intervals, reinforced concrete ribs with a constant width and a variable high. The wide glazed fascia between the covering and the external wall characterize the architectural image of the building.La iglesia, realizada en el Norte de la ciudad e insertada en un magnifico parque secular, tiene una estructura enteramente de hormigón armado visto. La cubierta, independiente de la articulación de los espacios internos, consiste en una planta cuadrada con una abertura central. Cuatro columnas circulares sostienen las cuatro vigas principales sobre las cuales se sitúan, a cortos intervalos, las ménsulas de hormigón armado de ancho constante y de altura variable. Una banda alta acristalada entre el paramento perimetral externo y la cubierta completan la composición arquitectónica de la obra

    Predimensionado óptimo de secciones mixtas de hormigón y acero en régimen elástico

    Get PDF
    Applying the method of the ideal section to calculate the concrete and Steel composite sections in elastic regime, two purposes appear: 1) To establish an adequacy criterion to avoid the paradoxal case in which the standard rolled steel section alone reaches more resistance, in elastic phase, than reinforcing it with a concrete slab forming a composite beam. 2) To define a criterion to obtain the best pre-design, intending to reach, at the same time, the admissible stresses in the most compressed concrete fibre and in the most tensioned steel. Finally, the results corresponding to some frequent steel sections and concrete qualities usual in building, have been settled in tables of easy practical application, for the pre-design of sections starting from the tensional state.Aplicando el método de la sección ideal para el cálculo de secciones mixtas de hormigón y acero en régimen elástico, se plantean dos objetivos: 1) establecer un criterio de adecuación, para evitar el caso paradójico en que sólo el perfil metálico alcanza más resistencia, en fase elástica, que al reforzarlo con una cabeza de hormigón formando la viga mixta; 2) definir un criterio de optimización para el predimensionado, en base a que se alcancen simultáneamente las tensiones admisibles en la fibra más comprimida del hormigón y en la más traccionada del acero. Finalmente se han recogido en tablas, de fácil aplicación práctica para el predimensionado de secciones a partir del estado tensional, los resultados correspondientes a algunos perfiles comerciales y calidades de hormigón usuales en edificación

    Bibliografía

    Get PDF

    Bibliografía

    Get PDF

    Noticias

    Get PDF

    Casa museo

    Get PDF
    Not available.No disponible

    Fractura del hormigón en régimen elástico y lineal un ejemplo: la presa de Fontana

    Get PDF
    Linear Elastic Fracture Mechanics can be applied to plain concrete provided the fracture process zone be small compared with the size of the structural element. In this situation the stress State at the tip of the crack can be characterized by means of the stress intensity factor. The first part of the paper considers modeling crack extension in concrete by the finite element method. The second part deals with an example problem, the cracked Fontana Dam.La Mecánica de la Fractura en régimen elástico y lineal es aplicable a grandes elementos de hormigón en masa porque la zona de fractura suele ser pequeña en comparación con las dimensiones del elemento estructural y es posible caracterizar, en estos casos, el estado tensional en el fondo de una fisura mediante el factor de intensidad de tensiones. El artículo consta de dos partes: En la primera se describen las técnicas de elementos finitos utilizadas para modelizar la propagación de una fisura y en la segunda parte se comenta la aplicación de las mismas a un caso real, el estudio de una fisura en una presa de gravedad

    Formas, tensiones y deformaciones en estructuras laminares con puntos singulares

    Get PDF