Diagnostic radiology and radiotherapy (E-Journal) / Лучевая диагностика и терапия
Not a member yet
    622 research outputs found

    Магнитно-резонансная морфометрия головного мозга при различных вариантах мультисистемной атрофии

    Get PDF
    Introduction. Neurodegenerative diseases occupy a significant place in the structure of diseases of the Central nervous system and have a high social and economic significance. One of the methods of more accurate neuroimaging assessment of the neurodegenerative process is magnetic resonance morphometry using specialized software. Purpose of research. To evaluate the possibilities of magnetic resonance morphometry as a method of differential diagnosis of parkinsonism syndromes and to investigate the characteristic of volumetric changes of individual brain structures in different variants of Multisystem atrophy. Materials and methods. Morphometric markers of Multisystem atrophy variants development using postprocessing processing of native MRI on Freesurfer software are analyzed. 24 patients with striatonigral degeneration and 20 patients with olivopontocerebellar degeneration were examined. Patients without relevant neurological pathology of appropriate age were examined as a control group. Magnetic resonance imaging was performed on a magnetic resonance tomograph of Siemens with magnetic field induction of 1,5 T. 240 structures from the right and left hemispheres of the brain were subjected to statistical analysis. There were significant differences in the distribution of atrophy among the structures of the brain stem and hemispheres in patients with olivopontocerebellar and striatonigral degeneration. Сonclusions. The obtained data of the study on the atrophy of cortical areas involved in the realization of cognitive functions showed the difference between the variants of Multisystem atrophy. Thus, striatonigral atrophy is characterized by a decrease in the thickness of the structures of the frontal cortex, while olivopontocerebellar degeneration reveals a decrease in the thickness of the parahippocampal zone. Methods of postprocessing processing of MR morphometry data allow to confirm the clinical diagnosis instrumentally, as well as to clarify the pathogenesis of neurodegenerative diseases and to clarify the distribution of the brain structures most susceptible to neurodegeneration.Введение. Нейродегенеративные заболевания занимают значительное место в структуре болезней центральной нервной системы и обладают высокой социальной и экономической значимостью. Одним из методов более точной нейровизуализационной оценки течения нейродегенеративного процесса является магнитно-резонансная морфометрия с использованием специализированного программного обеспечения. Цель исследования: оценить возможности магнитно-резонансной морфометрии в качестве метода дифференциальной диагностики отдельных синдромов паркинсонизма и исследовать характерные волюметрические изменения отдельных структур головного мозга при различных вариантах мультисистемной атрофии. Материалы и методы. Проанализированы морфометрические маркеры развития вариантов мультисистемной атрофии с помощью постпроцессинговой обработки нативных МР-изображений на программном обеспечении Freesurfer. Обследовано 24 пациентов с стриатонигральной дегенерацией и 20 пациентов с оливопонтоцеребеллярной дегенерацией. В качестве контрольной группы были обследованы пациенты без актуальной неврологической патологии соответствующего возраста. Магнитно-резонансная томография выполнялась на магнитно-резонансном томографе фирмы «Siemens» с индукцией магнитного поля 1,5 Тл. Статистическому анализу подвергались 240 структур из правого и левого полушария головного мозга. Получены достоверные различия в распределении атрофии среди структур ствола головного мозга и полушарий у пациентов с оливопонтоцеребеллярной и стриатонигральной дегенерацией. Выводы. Полученные нами данные об атрофии зон коры головного мозга, участвующих в реализации когнитивных функций, показали отличие между вариантами мультисистемной атрофии. Так, для стриатонигральной атрофии характерно уменьшение толщины структур лобной коры, в то время как при оливопонтоцеребеллярной дегенерации выявляется уменьшение толщины парагиппокампальной зоны. Методики постпроцессинговой обработки данных МР-морфометрии позволяют инструментально подтвердить клинический диагноз, а также уточнить патогенез нейродегенеративных заболеваний и уточнить распределение наиболее подверженных нейродегенерации структур головного мозга

    Выявление избыточного количества натрия в миокарде в условиях натриевой нагрузки с помощью двухэнергетической компьютерной томографии

    Get PDF
    Introduction. The direct relationship between the level of sodium intake, arterial hypertension, followed by the development of heart failure, a hypothesis of the direct influence of excessive sodium accumulation in myocardial glycosaminoglycans seems quite probable, which can further contribute to the occurrence of diastolic dysfunction and heart failure.The aim of the study was to identify excess sodium in rats under conditions of sodium loading, in comparison with rats at a normal level of sodium intake. Materials and methods. Ten male Wistar rats with the same body weight were divided into two groups: the excess salt intake group and the normal salt intake group. Estimation of the amount of Na and NaCl in the animal myocardium was performed using dual energy computed tomography (DECT) samples. Samples were scanned on a Revolution GSI tomograph (GE Healthcare). For statistical processing of the obtained data, the R language was used. Results. The results of the study showed that the accumulation of Na and NaCl does not depend on the average level of animal feed intake, there is no correlation between weight and accumulation of excess Na in tissues, the level of Na and NaCl detected in myocardial tissue significantly increases the likelihood of a high salt diet in rats, and a relationship between the content Na in the myocardium and NaCl+H2O. Conclusion. The experiment confirmed the existence of a reliable relationship between the sodium compounds calculated on the basis of DECT and the content of these compounds in the samples. The small number of samples did not allow us to calculate normalized rats, but we noted a clear difference between the control group and the high sodium diet.Введение. Учитывая прямую взаимосвязь между уровнем потребления натрия (Na), артериальной гипертензией с последующим развитием сердечной недостаточности, достаточно вероятным представляется гипотеза непосредственного влияния избыточного накопления Naвгликозаминогликанах миокарда, что в дальнейшем может способствовать возникновению диастолической дисфункции и сердечной недостаточности. Цель исследования: выявление избыточного количества натрия у крыс, находящихся в условиях натриевой нагрузки, в сравнении с крысами, находящимися на нормальном уровне потребления натрия. Материалы и методы. Десять самцов крыс рода Wistar с одинаковой массой тела были разделены на две группы: группа избыточного потребления соли и группа нормального потребления соли. Оценка количества натрия и NaCl в миокарде животных была выполнена при двухэнергетической компьютерной томографии (ДЭКТ) образцов. Сканирование образцов выполняли на томографе RevolutionGSI (GEHealthcare). Для статистической обработки полученных данных использовали язык R. Результаты исследования показали: накопление натрия и NaCl, не зависит от среднего уровня потребления корма животным, отсутствует корреляция между весом и уровнем накопления избытка натрия в тканях, уровень натрия и NaCl в ткани миокарда значимо повышают вероятность высокосолевой диеты у крысы, выявлена зависимость между содержанием натрия в миокарде и NaCl+Н2О. Заключение. Эксперимент подтвердил наличие достоверной связи вычисленных на основании ДЭКТ значений соединений натрия с содержанием этих соединений в образцах. Малое количество образцов не позволило нам рассчитать нормализованные показатели для крыс, однако мы отметили четкое различие между контрольной группой и группой с высоким содержанием натрия в диете

    ЛУЧЕВАЯ ДИАГНОСТИКА В ПЕДИАТРИИ

    Get PDF
    .

    ВОЗМОЖНОСТИ УЛЬТРАЗВУКОВОГО ИССЛЕДОВАНИЯ В ДИАГНОСТИКЕ ВОСПАЛИТЕЛЬНОЙ ИНФИЛЬТРАЦИИ ЛЕГКИХ

    Get PDF
    The purpose: to estimate the efficiency of ultrasound examination for diagnostics of lung inflammatory infiltration.Methods and materials: 106 patients with community-acquired pneumonia were examined. The complex of radiological examinations was performed. The dynamics of the inflammatory infiltrate was evaluated by standard X-ray examination and lungs ultrasound study.Results. The ultrasound pattern of pleuropneumonia and bronchopneumonia is systemized. The ultrasound examination demonstrated high sensitivity and specificity, in some cases prevailing the X-ray.Conclusion. The periods of ultrasound monitoring of the dynamics of the inflammatory process in the lungs are proposed.Цель: оценка информативности ультразвукового исследования в диагностике воспалительной инфильтрации легких.Материалы и методы. Обследованы 106 пациентов с внебольничной пневмонией. Проведен комплекс лучевых методов диагностики. Динамика процесса оценивалась с помощью стандартной рентгенографии и ультразвукового исследования легких.Результаты. Систематизирована ультразвуковая картина плевропневмонии и бронхопневмонии. Ультразвуковой метод продемонстрировал высокую чувствительность и специфичность, в ряде случаев показав более высокую информативность в сравнении с рентгенографией.Заключение. Предложены сроки ультразвукового мониторирования динамики  воспалительного процесса в легких

    ЭВОЛЮЦИЯ ИЗМЕНЕНИЙ В ЛЕГКИХ ПО ДАННЫМ КТ ПРИ ДИНАМИЧЕСКОМ НАБЛЮДЕНИИ ПАЦИЕНТОВ С COVID-19 В РАННИЕ СРОКИ

    Get PDF
    The aim of the study: to identify the main variants of CT-symptoms («scenarios») which are observed in patients with COVID-19 viral lung damage with positive clinical course.Materials and methods. We considered follow-up CT data of patients with SARS-nCoV-2 virus infection (confirmed by PCR) with a difference of 5 to 21 days with a positive clinical course of the disease. In some cases, a correlation with morphological data was made.Results. There were identified 5 main «scenarios» for viral lung damage course in COVID-19 (from  complete regression of opacities or minimal residual reticular structures to the phenomena of organization,  atelectasises and initial signs of fibrosis).Conclusions. Understanding of follow-up CT pattern in COVID-19 helps to make a decision at an early stage about necessity for additional therapy, which allows to avoid potentially possible fibrotic lung process in the future.Цель: выделить основные варианты КТ-картины («сценарии»), которые наблюдаются при положительной динамике вирусного поражения легких у больных с COVID-19.Материалы и методы. Рассмотрены КТ-данные пациентов с подтвержденной вирусной инфекцией SARS-nCoV-2 (ПЦР) в динамике с разницей от 5 до 21 дня при положительном клиническом течении заболевания, выполненных за время работы в COVID-центрах г. Москвы. В части случаев проведена корреляция с морфологическими данными.Результаты. Были выделены 5 основных «сценариев», по которым происходит разрешение вирусного поражения легких при коронавирусной инфекции (от полного регресса уплотнений или минимальных остаточных изменений до явлений организации,  ателектазирования и начальных признаков фиброза).Заключение. Понимание КТ-картины в динамике при COVID-19 помогает уже на ранних этапах принять решение о необходимости применения дополнительной терапии, позволяющей в дальнейшим избежать потенциально возможных фиброзных изменений в легких

    СРАВНЕНИЕ РАЗЛИЧНЫХ ПОДХОДОВ К ОЦЕНКЕ ДИАГНОСТИЧЕСКОГО КАЧЕСТВА КОМПЬЮТЕРНОЙ ТОМОГРАФИИ ОРГАНОВ ГРУДНОЙ КЛЕТКИ

    Get PDF
    The aim of the current study was to assess the physical and technical image quality parameters of the CT images obtained on low-dose chest protocols.Materials and methods. The study was performed using the ACR CT PHANTOM on the Philips Ingenuity 128 CT unit. The following parameters were selected for the assessment of image quality: Hounsfield unit accuracy, image noise, contrast to noise ratio and spatial resolution.The results of the study indicate the lack of significant differences between the selected low-dose protocols.  Additionally, the correlation between the results of the assessment of physical and technical parameters of CT  images and expert image quality evaluation was weak. That does not allow implementing the low-dose protocols  into clinical practice based solely on the assessment of the physical and technical parameters.Целью данной работы являлась оценка физико-технических параметров качества КТ-изображений, выполненных на низкодозовых протоколах сканирования органов грудной клетки.Материалы и методы. Работа выполнена с использованием фантома ACR CT PHANTOM для компьютерного томографа Philips Ingenuity 128. Оценка качества изображения  осуществлялась по точности определения единиц Хаунсфилда, шума изображения, отношения контраста к шуму и пространственного разрешения.Результаты исследования показали, отсутствие достоверных различий между различными низкодозовыми протоколами. При этом наблюдалась слабая корреляция между результатами физико-технических параметров изображения и экспертной оценки качества изображения, что не позволяет принимать решение о внедрении низкодозовых протоколов в практику, основываясь только на оценке физико-технических параметров

    Эффективность мультипараметрического ультразвукового исследования с применением компрессионной эласто-графии в ранней диагностике образований молочной железы

    Get PDF
    Modern ultrasound examination (US), unlike other modalities, allows to assess the stiffness of the lesions, with the help of a new technology named sonoelastography (SEG). According to many scientific studies, with the addition of SEG to the B-mode, the diagnostic efficiency of ultrasound of breast lesions significantly increases. According to Thomas et al. B-mode has a sensitivity of 91,8% and a specificity of 78%. When a compression SEG is added to a diagnostic study, the specificity increases to 91,5%.The purpose of this study was to determine the diagnostic effectiveness of SEG and compare it with the effectiveness of B-mode and color Doppler mapping (CDC) in the primary diagnosis of breast tumors, as well as to identify diagnostically and statistically significant SEG signs of breast cancer (ВС).Materials and methods. The study was performed from 2017 to 2019 on the basis of the «NMRC Oncology. named after N. N. Petrov» Ministry of Health of Russia. 277 women with complaints of lump or pain in the breast were included in the study, for all of them there was performed the multiparametric ultrasound examination with application of CDM and SEG. According to our own results, SEG is more effective at detection of malignant and benign lesions, than ultrasoumd examination in B and CDM modes.Results: 0, 1, 2, 3 elastotypes are the highly significant diagnostic signs of benign process, and the elastotype 5 is a reliable diagnostic marker of malignant process. The effectiveness of CDM and SEG in the differential diagnosis of breast lesions showed: sensitivity — 77,6% vs. 85,5%; specificity — 51,7% vs. 84,6%; accuracy — 58,8% vs. 84,8%.Conclusions: according to our own research results, SEG is more effective in detecting malignant and benign tumors than ultrasound in B and CDM modes.Введение. Современное ультразвуковое исследование (УЗИ) в отличие от других модальностей позволяет оценивать жесткость патологического очага с помощью новой технологии — соноэластографии (СЭГ). Согласно многим научным исследованиям при добавлении СЭГ к серошкальному В-режиму значимо повышается диагностическая эффективность УЗИ образований молочной железы. По данным А. Thomas и соавт. В-режим имеет чувствительность 91,8% и специфичность 78%. При добавлении к диагностическому исследованию компрессионной СЭГ специфичность увеличивается до 91,5%.Целью и задачей данного исследования явилось определение диагностической эффективности СЭГ и сравнение с эффективностью В-режима и цветового допплеровского картирования (ЦДК) в первичной диагностике образований молочной железы, а также выявление диагностически и статистически значимых СЭГ признаков рака молочной железы (РМЖ).Материалы и методы. Исследование проводилось с 2017 по 2019 г. на базе ФГБУ «НМИЦ онкологии им. Н. Н. Петрова» МЗ РФ. В исследование были включены 277 женщин с жалобами на образование или болезненные ощущения в молочных железах, всем им выполнялось мультипараметрическое УЗИ с применением ЦДК и СЭГ.Результаты исследования: к высокозначимым диагностическим признакам доброкачественного процесса относятся 0, 1, 2, 3 эластотипы, а 5 эластотип является достоверным диагностическим маркером злокачественного. Эффективность ЦДК и СЭГ в дифференциальной диагностике образований молочной железы показала: чувствительность — 77,6% против 85,5%; специфичность — 51,7% против 84,6%; точность — 58,8% против 84,8%.Выводы: согласно собственным результатам исследования, СЭГ более эффективна в диагностике злокачественных и доброкачественных образований, чем ультразвуковые В- и ЦДК-режимы

    Высокотехнологичные методы в диагностике рака гортани: клинический случай

    Get PDF
    Summary. The article observes the possibilities of high-technologic radiologic methods for diagnostics of laryngeal malignancy. Despite of large amount of publications, dedicated to the question of different radiologic imaging modalities application for laryngeal tumors the aspects of complex radiological examination and highly differentiated laryngeal tumors detection are not well described.Materials and methods. In our article there is the case of diagnostic process in 56-years old male patient complained on voice changes with the right vocal fold neoplasm detected in laryngeal videoendoscopy, which had ambiguous pattern in autofluorescence. The results of laryngeal videoendoscopy included differently colored zones from white ones, which corresponded to benign tissue, to blue and violet ones, which corresponded to malignancy. The patient was examined with contrast-enhanced computed tomography, contrast-enhanced magnetic resonance imaging with diffusion-weighted protocol and combined positron-emission and computed tomography with 18F-fluorodeoxyglucose.Results. Computed tomography data showed the right vocal fold thickening without contrast agent uptake, on magnetic resonance images there was detected the irregular thickening of the same fold, also without contrast medium agent uptake. In positron-emission and computed tomography with 18F-fluorodeoxyglucose a focal radiotracer hypermetabolism with highly increased standard uptake value was detected, which indicated malignancy. In addition distant metastases in thoracic lymph nodes were found. Pathomorphologic diagnosis of high-differentiated laryngeal cancer was established.Discussion. Highly differentiated laryngeal malignant tumors can imitate benign process on computed tomography and magnetic resonance imaging because of peculiar cell composition, but they are characterized with 18F-fluorodeoxyglucose hyperfixation conditioned by glycolytical activity of malignant cells. Negative computed tomography and magnetic resonance imaging data in combination with positive positron-emission and computed tomography results may correspond to highly differentiated laryngeal tumor.Введение. В статье рассматривается возможность использования высокотехнологичных методов лучевой диагностики при наличии онкологического процесса в гортани. Несмотря на большое количество работ в данной области по использованию отдельных лучевых методов исследования, применение комплексной лучевой диагностики и проблема выявления высокодифференцированных опухолей в современной литературе не освещены.Материалы и методы. Ниже приводится клинический случай диагностического поиска у 56-летнего мужчины, предъявлявшего жалобы на изменение голоса, у которого при видеоэндоскопии гортани было выявлено образование правой голосовой складки со «спорной» аутофлюоресценцией: от белых участков, говорящих о доброкачественности процесса, до зон сине-фиолетового цвета, свидетельствующих о злокачественности. Пациенту было проведено комплексное лучевое обследование, включавшее компьютерную томографию с внутривенным контрастным усилением, магнитно-резонансную томографию с протоколом диффузионного взвешивания и совмещенную позитронно-эмиссионную и компьютерную томографию с 18F-фтордезоксиглюкозой.Результаты. При компьютерной томографии отмечалось утолщение правой голосовой связки без накопления контрастного вещества. При магнитно-резонансной томографии также отмечалось неравномерное утолщение правой голосовой складки без накопления контрастного вещества в ней и без признаков ограничения диффузии на диффузионно-взвешенных изображениях. При выполнении совмещенной позитронно-эмиссионной и компьютерной томографии с 18F -фтордезоксиглюкозой в образовании отмечался участок гиперметаболизма радиоафармпрепарата со значительно повышенным значением стандартизованного уровня захвата, свидетельствовавшим о злокачественности процесса. Кроме того, были выявлены отдаленные метастазы во внутригрудные лимфатические узлы. При гистологической верификации был установлен диагноз высокодифференцированного рака гортани.Обсуждение. Высокодифференцированные злокачественные опухоли гортани вследствие особенностей клеточного строения могут имитировать доброкачественный процесс при компьютерной и магнитно-резонансной томографии, однако характеризуются высоким уровнем фиксации 18F-фтордезоксиглюкозы вследствие наличия гликолитической активности злокачественных клеток. Сочетание отрицательных результатов компьютерной и магнитно-резонансной томографии и положительных — совмещенной позитронно-эмиссионной и компьютерной томографии с 18F-фтордезоксиглюко-зой указывает на наличие высокодифференцированной опухоли гортани

    Лучевые проявления новой коронавирусной инфекции COVID-19

    Get PDF
    Purpose. To evaluate the radiological patterns of a new COVID-19 coronavirus infection. Materials and methods. Review of literature sources. Results. COVID-19 causes the acute severe viral pneumonia. Radiological diagnostics of COVID-19 is very important, because CT can be the first study that shows the signs of viral lung lesion, and allows to assess the severity of the lesion and adverse prognostic signs of its further development. The initial CT pattern of COVID-19 is a pattern of infiltration of secondary pulmonary lobules on the type of «frosted glass» (a symptom of «dry leaf») with a subsequent decrease in the volume of lesions at favorable results, or their increase, accession of CT pattern of «cobblestone road» and the appearance in the area of «frosted glass» the alveolar infiltration in unfavorable course of disease. These symptoms are the precursors to the development of respiratory distress syndrome. At a later primary examination, the primary CT symptoms are the pattern of «cobblestone road» and areas of alveolar infiltration, which correlates with an unfavorable further course and outcome. There was noted that viral pneumonia in COVID-19 was characterized by the location of changes in the posterior subpleural and peribronchial areas. All authors confirmed that cavities, nodules, pleural and pericardial effusions, and lymphadenopathy were absent in COVID-19. In the course of observation, quantitative characteristics of the lesions with a score were proposed, the use of which can help in determining the prognosis. Also identified temporary staging of the process and the formation in some of patients the residual changes in the lungs the same as in influenza pneumonia H1N1 (2008–9гг, 2015–16.) and SARS SARS-CoV-2 (2003)which can start the process of development of progressive pulmonary fibrosis. There is a need for frequent CT studies (every 4 days) to enable timely assessment of rapid dynamics and changes in treatment tactics. The analysis of the results of the examination should be performed by at least 2 radiologists experienced in thoracic radiology, with the involvement of a third independent expert, in case of disagreement. All the authors confirmed the low information content of traditional radiography in assessing viral lung lesions. In some studies, chest radiographs were not performed, only CT as a more sensitive method for detecting early changes, similar to previous outbreaks of coronavirus. However, the role of traditional radiography was recognized as unquestionable when evaluating changes in reanimation department conditions. Conclusions. The accumulation of experience in clinical and radiological examination of COVID-19 patients allowed to determine the radiological semiotics of the process, which is important for determining the treatment tactics.Цель исследования: оценить лучевые паттерны новой коронавирусной инфекции COVID-19. Материалы и методы. Обзор литературных источников. Результаты. COVID-19 вызывает острую тяжелую форму вирусной пневмонии. Лучевая диагностика COVID-19 очень важна, так как компьютерная томография (КТ) может быть первым исследованием, которое демонстрирует признаки вирусного поражения легких, позволяет оценить тяжесть поражения и неблагоприятные прогностические признаки его дальнейшего развития. Первичным КТ-паттерном COVID-19 является картина инфильтрации отдельных вторичных легочных долек по типу «матового стекла» (симптом «сухого листа») с последующим уменьшением объема поражения при благоприятном развитии событий либо их нарастании, присоединении КТ-картины «булыжной мостовой» и появлении в зоне «матового стекла» альвеолярной инфильтрации при неблагоприятном варианте течения заболевания. Эти симптомы являются предвестниками развития респираторного дистресс-синдрома. При более позднем первичном обследовании первичными КТ-симптомами становится паттерн «булыжной мостовой» и участки альвеолярной инфильтрации, что коррелирует с неблагоприятным дальнейшим течением и исходом. Отмечено, что для вирусной пневмонии при COVID-19 было характерно расположение изменений в задних субплевральных и перибронхиальных отделах. Все авторы подтверждали, что полости, узловые образования, плевральные и перикардиальные выпоты и лимфаденопатия при COVID-19 отсутствовали. В процессе наблюдения были предложены количественные характеристики поражения с балльной оценкой, использование которых может помочь в определении прогноза. Также была определена временная стадийность процесса и формирование у части больных остаточных изменений в легких, которые, как при гриппозной пневмонии H1N1 (2008–2019 гг., 2015–2016 гг.) и атипичной пневмонии SARS-CoV-2 (2003 г.), могут запускать процессы развития прогрессирующего легочного фиброза. Отмечается необходимость частого проведения КТ-исследований (каждые 4 дня) для возможности своевременной оценки быстрой динамики и изменения лечебной тактики. Анализ результатов обследования должны проводить минимум два рентгенолога, имеющих опыт работы в торакальной радиологии, с привлечением третьего независимого эксперта, в случае расхождения мнений. Все авторы подтверждали низкую информативность традиционной рентгенографии в оценке вирусного поражения легких, в некоторых исследованиях не выполнялась рентгенография грудной клетки, применяли только КТ как более чувствительный метод выявления ранних изменений, по аналогии с предыдущими вспышками коронавируса. Однако роль традиционной рентгенографии признавалась несомненной при оценке изменений в условиях реанимации. Выводы. Накопление опыта клинико-лучевого обследования больных COVID-19 позволил определить лучевую семиотику процесса, важную для определения лечебной тактики

    591

    full texts

    622

    metadata records
    Updated in last 30 days.