1,720,964 research outputs found

    Successful Off-Label Use of an Iliac Branch Device to Rescue an Occluded Aortofemoral Bypass Graft

    No full text
    Purpose: To report an alternative approach for rescue of an occluded aortofemoral bypass using the Gore Excluder Iliac Branch Endoprosthesis (IBE). Case Report: A 52-year-old man presented with acute right limb ischemia because of displaced and occluded iliac stents and was treated with aortofemoral bypass. On the third postoperative day, there was early bypass failure due to distal embolization from aortic thrombus. After fluoroscopy-guided balloon thrombectomy of the bypass, an endovascular bailout strategy was used. The Gore Excluder IBE was deployed below the renal arteries (with the external iliac limb opening in the surgical prosthesis and the gate opening within the aortic lumen). After antegrade catheterization of the gate, a Gore Viabahn endoprosthesis was inserted as the bridging endograft and deployed so that it landed just above the preimplanted aortoiliac kissing stents without overlapping them. Completion angiography showed technical success without complications; results were sustained at 1-year follow-up. Conclusion: The Gore Excluder IBE may represent a versatile solution for the rescue of complex cases when open surgery would be associated with a considerable risk. This off-label application of a well-recognized endovascular device is safe and feasible and may prove useful as a valuable alternative in properly selected patients

    Going Beyond Counting First Authors in Author Co-citation Analysis

    Get PDF
    The present study examines one of the fundamental aspects of author co-citation analysis (ACA) - the way co-citation counts are defined. Co-citation counting provides the data on which all subsequent statistical analyses and mappings are based, and we compare ACA results based on two different types of co-citation counting - the traditional type that only counts the first one among a cited work's authors on the one hand and a non-traditional type that takes into account the first 5 authors of a cited work on the other hand. Results indicate that the picture produced through this non-traditional author co-citation counting contains more coherent author groups and is therefore considerably clearer. However, this picture represents fewer specialties in the research field being studied than that produced through the traditional first-author co-citation counting when the same number of top-ranked authors is selected and analyzed. Reasons for these effects are discussed

    Custom-Made Unibody Conical Endografts for Elective Endovascular Repair of Saccular Infrarenal Abdominal Aortic Aneurysms with Narrow Aortic Bifurcations—Novel Implementation of the Aortoaortic Concept

    No full text
    The aortoaortic concept for endovascular repair (EVAR) of infrarenal abdominal aortic aneurysms (AAAs) is nearly forgotten but may constitute a valuable option for focal pathologies. Herein, we describe our experience using custom-made (CM) unibody conical endografts for saccular AAAs with narrow (≤20 mm wide) aortic bifurcation (AB) in three patients. Given the narrow AB, the option for a bifurcated stent graft was reputed not optimal. Therefore, we decided to further suggest the construction of a CM unibody conical stent graft with respect to unique anatomical characteristics of the patients. Technical success rate was 100%, and computed tomography angiography at first-month follow-up showed complete sealing proximally and distally with excellent conformability of the endografts in all the cases. All the patients were free from any-type endoleak (EL) and had no evidence of any endograft-related complication (i.e., fracture, thrombosis, or migration) or required any reintervention at their longest follow-up. We conclude that in the proper anatomic setting, the use of CM unibody conical endografts for elective EVAR of saccular AAAs with narrow AB is technically feasible with excellent short-term safety regarding ELs or migration

    Urgent Use of Gore Excluder Iliac Branch Endoprosthesis with Left Transaxillary Approach for Preservation of the Residual Hypogastric Artery: A Case Series

    No full text
    Background: Preservation of the residual hypogastric artery (HGA) in patients with previous endovascular aortic aneurysm repair (EVAR) may require complex operative strategies. We report an alternative technique to preserve the residual HGA with the Gore Excluder Iliac Branch endoprosthesis (IBE) in urgent situations. Methods: We report the case of 2 high-risk patients (unfit for open surgery), with previous EVAR and exclusion of 1 HGA, treated in emergency setting. Both patients met the anatomical requirements for Gore IBE use. Due to lack of the native aortic bifurcation, we used a transaxillary approach to deploy a covered stent (Gore Viabahn) in the target HGA. Results: Technical success was 100%. Computed tomography angiography at 30 days, 6 months, and 1 year showed regular placement of all endografts and patency of all residual HGAs without evidence of any endograft-related complication (i.e., stent fracture, stent thrombosis or stent displacement). There was not any detectable type 1, 2, or 3 endoleak at longest follow-up. Conclusions: Our case series shows the technical feasibility and the good results of this approach, which may prove useful when the native aortoiliac carrefour is no longer available. The procedure seems to be safe and effective, with optimal primary patency of the stent grafts, freedom from type 1, 2, and 3 endoleaks, and absence of pelvic ischemic complications

    Secondary Endovascular Repair of Recurring Lesions and Perioperative Complications after Open Aortic Repair: The Complementary Role of Different Technical Solutions

    No full text
    Background: The aim of our article was to describe the complementary role of different technical solutions for secondary endovascular repair of recurring lesions and perioperative complications after open aortic repair (OAR). Methods: We describe our clinical experience of secondary endovascular repair after OAR. We included in the analysis all consecutive patients who presented recurring lesions and perioperative complications after OAR and underwent secondary endovascular repair between January 1, 2015 and June 31, 2018. Both elective and nonelective cases were captured. Early end points were technical success, 30-day mortality, 30-day major adverse events, and 30-day vascular access complications. Late end points were survival and freedom from secondary interventions. Results: Three different techniques were used in 6 patients: 2 cases of fenestrated–branched endovascular aortic repair (F-BEVAR), 2 cases of parallel-graft EVAR (pg-EVAR), and 2 cases of off-label use of standard devices. Technical success was 100%. One patient died within 30 days from acute pulmonary embolism. One patient developed acute kidney injury not requiring renal replacement therapy, whereas the remaining 4 patients were free from 30-day major adverse events. The cumulative rate of 30-day vascular access complications was 0%. All the 5 patients who survived the index hospitalization had ≥12 months of clinical and imaging follow-up. At the longest individual follow-up, they all were alive and free from secondary interventions. Computed tomography angiography showed in all cases sustained clinical success. Conclusions: Secondary endovascular repair of recurring lesions and perioperative complications after OAR is safe and feasible and offers a minimally invasive effective treatment option when a redo surgical operation would be associated with a considerable risk to the patient. Different solutions are available (including F-BEVAR, pg-EVAR, and off-label use of standard devices) and are complementary rather than competitive. Careful preoperative assessment and familiarity with advanced techniques are essential to achieve satisfactory outcomes

    Hybrid Treatment of a True Right Subclavian Artery Aneurysm Involving the Vertebral Artery using a Covered Stent

    No full text
    Subclavian artery aneurysms (SAAs) are rare but potentially life- and limb-threatening. We present the case of a 69-year-old man with a true right SAA; the vertebral artery branched off the aneurysm and was the dominant one. A hybrid (combined open surgical and endovascular) repair was performed; the vertebral artery was anastomosed end to side to the common carotid artery through a right supraclavicular incision, then using a percutaneous high brachial artery access, a covered stent was deployed to exclude the SSA. The procedure was technically successful, and computed tomography angiography at 24 months showed regular placement of the endograft with blood flow within it and absence of any endograft-related complication (i.e., stent fracture/thrombosis/displacement or any-type detectable endoleak). This hybrid treatment is safe and feasible with good midterm results and may represent a valuable, less invasive alternative to conventional open surgical approaches

    Treatment of Complex Abdominal Aortic Aneurysms with Parallel Graft-Endovascular Aneurysm Repair. Retrospective Analysis of a Single Center Experience and Midterm Results

    No full text
    Background: We sought to evaluate the midterm results of parallel-graft-endovascular aneurysm repair (pg-EVAR) for complex aortic anatomy in high-risk candidates for open surgical repair of abdominal aortic aneurism (AAA). Methods: Clinical and radiographic information on 35 patients treated by pg-EVAR between March 2010 and December 2015 was retrospectively reviewed and analyzed. All patients presented with symptomatic aneurysms and were treated within 3 days of clinical presentation. Primary end points included primary chimney graft patency, overall survival, and freedom from all reintervention. Results: Overall, 55 chimney grafts were placed into 47 renal arteries and 8 superior mesenteric arteries in 35 patients. An endurant stent graft was used as the main body component in all cases. At 36 months, primary chimney graft patency was 88%, overall survival of patients was 71%, and the rate of freedom from all reintervention was 78%. Conclusions: Considering our midterm results, pg-EVAR seems to be a safe and effective treatment for patients with complex anatomies and at poor risk for open repair

    Variations on the Author

    Get PDF
    “Variations on the Author” discusses two of Eduardo Coutinho’s recent films (Um Dia na Vida, from 2010, and Últimas Conversas, posthumously released in 2015) and their contribution to the general question of documentary authorship. The director’s filmography is characterized by a consistent yet self-effacing form of authorial self-inscription: Coutinho often features as an interviewer that rather than express opinions propels discourses; an interviewer that is good at listening. This mode of self-inscription characterizes him as an author who is not expressive but who is nonetheless markedly present on the screen. In Um Dia na Vida, however, Coutinho is completely absent form the image, while Últimas Conversas, on the contrary, includes a confessional prologue that moves the director from the margins to the center of his films. This article examines the ways in which these works stand out in the filmography of a director who offers new insights into the notion of cinematic authorship

    Appropriate Similarity Measures for Author Cocitation Analysis

    Get PDF
    We provide a number of new insights into the methodological discussion about author cocitation analysis. We first argue that the use of the Pearson correlation for measuring the similarity between authors’ cocitation profiles is not very satisfactory. We then discuss what kind of similarity measures may be used as an alternative to the Pearson correlation. We consider three similarity measures in particular. One is the well-known cosine. The other two similarity measures have not been used before in the bibliometric literature. Finally, we show by means of an example that our findings have a high practical relevance.information science;Pearson correlation;cosine;similarity measure;author cocitation analysis
    corecore