289 research outputs found
sj-docx-1-nms-10.1177_14614448211063899 – Supplemental material for No trade-offs between news and entertainment: Evidence from online engagement data
Supplemental material, sj-docx-1-nms-10.1177_14614448211063899 for No trade-offs between news and entertainment: Evidence from online engagement data by Shengchun Huang and Tian Yang in New Media & Society</p
Recent Development in ITO-free Flexible Polymer Solar Cells
Polymer solar cells have shown good prospect for development due to their advantages of low-cost, light-weight, solution processable fabrication, and mechanical flexibility. Their compatibility with the industrial roll-to-roll manufacturing process makes it superior to other kind of solar cells. Normally, indium tin oxide (ITO) is adopted as the transparent electrode in polymer solar cells, which combines good conductivity and transparency. However, some intrinsic weaknesses of ITO restrict its large scale applications in the future, including a high fabrication price using high temperature vacuum deposition method, scarcity of indium, brittleness and scaling up of resistance with the increase of area. Some substitutes to ITO have emerged in recent years, which can be used in flexible polymer solar cells. This article provides the review on recent progress using other transparent electrodes, including carbon nanotubes, graphene, metal nanowires and nanogrids, conductive polymer, and some other electrodes. Device stability is also discussed briefly
Anion-Dependent Construction of Two Hexanuclear 3D-4F Complexes with a Flexible Schiff Base Ligand
Two hexanuclear 3d-4f Ni-Eu and Cu-Eu complexes [Eu4Ni2L2(OAc)(12)(EtOH)(2)] (1) and [Eu4Cu2L2(OAc)(12)]center dot 2H(2)O (2) are reported which are formed from the salen type Schiff-base ligand H2L (H2L = N,N'-bis(3-methoxysalicylidene)butane-1,4-diamine). In both complexes, four Eu3+ cations are bridged by eight OAc- groups and the chain is terminated at each end by two ML (M = Ni and Cu) units. The structures of 1 and 2 were determined by single crystal X-ray crystallographic studies and the luminescence properties of the free ligand and metal complexes in solution were measured.HHMI Undergraduate Science Education Award 52005907National Science Foundation CHE-0629136, CHE-0741973, CHE-0847763Welch Foundation F-1631, F-816Hong Kong Baptist University FRG/06-07/II-16Hong Kong Research Grants Council HKBU 202407Priority Academic Program Development of Jiangsu Higher Education Institutions (PAPD)Open Foundation of Jiangsu Province Key Laboratory of Fine Petrochemical Technology KF1005UT-CNM and UT-AustinChemistr
Performance Comparison between Data Centers with Different Airflow Management Technologies
Air cooling systems are widely used in current data centers owing to their low capital costs and high reliability. To satisfy the increasing rack power density, the optimal air-cooling technology and an economic analysis should be carefully discussed. Therefore, this study discusses four airflow management technologies: Case 1: raised floor and cold aisle containment supply/computer room air conditioning (CRAC) direct return; Case 2: CRAC direct supply/hot aisle containment (HAC) return; Case 3: overhead duct supply/CRAC direct return; and Case 4: overhead duct supply/HAC return. Using a validated model, the thermal and economic performances of each case were compared. Results showed that Case 4 exhibited the best thermal performance, followed by Cases 3, 2, and 1. Case 1 cannot satisfy the heat dissipation requirement when the rack power density is larger than 12.5 kW; whereas only Case 4 can be used when the power density is larger than 15 kW. Regarding location within China, owing to the high ambient temperature, Shenzhen showed the highest annual cost value and power usage effectiveness, followed by Shanghai, Xi’an, Beijing, and Harbin. Finally, Cases 3 and 4 are recommended for application when the rack power density is greater than 10 kW.Green Open Access added to TU Delft Institutional Repository 'You share, we take care!' - Taverne project https://www.openaccess.nl/en/you-share-we-take-care Otherwise as indicated in the copyright section: the publisher is the copyright holder of this work and the author uses the Dutch legislation to make this work public.Process and Energ
Simulation on the Distribution of Solid Ice and Prediction of Ice Blockage for Ice Slurry in Horizontal Straight Tubes
AbstractIce slurry has been widely used as a second refrigerant for its high energy density and pumpability in HVAC systems and other district cooling areas. However, the ice blockage becomes a serious problem for the application of ice slurry, which makes the thermal storage technology unavailable in many cases. In this paper, the distribution of the ice crystals is analyzed in the straight tubes to predict and avoid ice blockage based on numerical simulation by kinetic theory of granular. Additionally, it is proposed in this paper that two index parameters, the maximum concentration (namely, the volume fraction, so as the following ones) and the minimum concentration of ice particles, are proved useful to evaluate the risk of the ice blockage, not previously considered. Three distinguished flow patterns has been observed keeping accordance with previous research. The most remarkable conclusion is that optimum flow velocity exists just between these two critical velocities to prevent ice blockage to the most degree
- …