1,720,959 research outputs found

    Resolving multipath interference in time-of-flight imaging via modulation frequency diversity and sparse regularization

    Get PDF
    Time-of-flight (ToF) cameras calculate depth maps by reconstructing phase shifts of amplitude-modulated signals. For broad illumination of transparent objects, reflections from multiple scene points can illuminate a given pixel, giving rise to an erroneous depth map. We report here a sparsity-regularized solution that separates K interfering components using multiple modulation frequency measurements. The method maps ToF imaging to the general framework of spectral estimation theory and has applications in improving depth profiles and exploiting multiple scattering.National Science Foundation (U.S.) (NSF grant 1115680)Charles Stark Draper Laboratory (grant SC001-744)International Society for Neurochemistry (ISN grant 6927356)University of Waikato (Doctoral Scholarship)Charles Stark Draper Laboratory (fellowship

    Going Beyond Counting First Authors in Author Co-citation Analysis

    Get PDF
    The present study examines one of the fundamental aspects of author co-citation analysis (ACA) - the way co-citation counts are defined. Co-citation counting provides the data on which all subsequent statistical analyses and mappings are based, and we compare ACA results based on two different types of co-citation counting - the traditional type that only counts the first one among a cited work's authors on the one hand and a non-traditional type that takes into account the first 5 authors of a cited work on the other hand. Results indicate that the picture produced through this non-traditional author co-citation counting contains more coherent author groups and is therefore considerably clearer. However, this picture represents fewer specialties in the research field being studied than that produced through the traditional first-author co-citation counting when the same number of top-ranked authors is selected and analyzed. Reasons for these effects are discussed

    Variations on the Author

    Get PDF
    “Variations on the Author” discusses two of Eduardo Coutinho’s recent films (Um Dia na Vida, from 2010, and Últimas Conversas, posthumously released in 2015) and their contribution to the general question of documentary authorship. The director’s filmography is characterized by a consistent yet self-effacing form of authorial self-inscription: Coutinho often features as an interviewer that rather than express opinions propels discourses; an interviewer that is good at listening. This mode of self-inscription characterizes him as an author who is not expressive but who is nonetheless markedly present on the screen. In Um Dia na Vida, however, Coutinho is completely absent form the image, while Últimas Conversas, on the contrary, includes a confessional prologue that moves the director from the margins to the center of his films. This article examines the ways in which these works stand out in the filmography of a director who offers new insights into the notion of cinematic authorship

    Appropriate Similarity Measures for Author Cocitation Analysis

    Get PDF
    We provide a number of new insights into the methodological discussion about author cocitation analysis. We first argue that the use of the Pearson correlation for measuring the similarity between authors’ cocitation profiles is not very satisfactory. We then discuss what kind of similarity measures may be used as an alternative to the Pearson correlation. We consider three similarity measures in particular. One is the well-known cosine. The other two similarity measures have not been used before in the bibliometric literature. Finally, we show by means of an example that our findings have a high practical relevance.information science;Pearson correlation;cosine;similarity measure;author cocitation analysis

    Dispelling the Myths Behind First-author Citation Counts

    Get PDF
    We conducted a full-scale evaluative citation analysis study of scholars in the XML research field to explore just how different from each other author rankings resulting from different citation counting methods actually are, and to demonstrate the capability of emerging data and tools on the Web in supporting more realistic citation counting methods. Our results contest some common arguments for the continued use of first-author citation counts in the evaluation of scholars, such as high correlations between author rankings by first-author citation counts and other citation counting methods, and high costs of using more realistic citation counting methods that are not well-supported by the ISI databases. It is argued that increasingly available digital full text research papers make it possible for citation analysis studies to go beyond what the ISI databases have directly supported and to employ more sophisticated methods

    Author Index

    No full text
    Nao informado

    koamabayili/VECTRON-author-checklist: VECTRON author checklist

    No full text
    We have done our best to complete the author checklist relating to the use of animals in the hut study. Note that the objective for the hut study was to evaluate the IRS treatment applications for residual efficacy against Anopheles mosquitoes, including the local An. coluzzii mosquito population. Cows were only used to attract mosquitoes into the huts and no tests were carried out directly on the cows. The author checklist is intended for use with studies where experiments are carried out on animals, which is why we have had such difficulty in completing this for the hut study, as many of the questions do not relate to how the cows were used

    Resolving Measurement Errors Inherent with Time-of-Flight Range Imaging Cameras

    No full text
    Range imaging cameras measure the distance to objects in the field-of-view (FoV) of the camera, these cameras enable new machine vision applications in robotics, manufacturing, and human computer interaction. Time-of-flight (ToF) range cameras operate by illuminating the scene with amplitude modulated continuous wave (AMCW) light and measuring the phase difference between the emitted and reflected modulation envelope. Currently ToF range cameras suffer from measurement errors that are highly scene dependent, and these errors limit the accuracy of the depth measurement. The major cause of measurement errors is multiple propagation paths from the light source to pixel, known as multi path interference. Multi-path interference typically arises from: inter reflections, lens flare, subsurface scattering, volumetric scattering, and translucent objects. This thesis contributes three novel methods for resolving multi-path interference: coding in time, coding in frequency, and coding in space. Time coding is implemented by replacing the single frequency amplitude modulation with a binary sequence. Fundamental to ToF range cameras is the cross-correlation between the reflected light and a reference signal. The measured cross-correlation depends on the selection of the binary sequence. With selection of an appropriate binary sequence and using sparse deconvolution on the measured cross-correlation the multiple return path lengths and their amplitudes can be recovered. However, the minimal resolvable path length is dependent on the highest frequency in the binary sequence. Frequency coding is implemented by taking multiple measurements at different modulation frequencies. A subset of frequency coding is operating the camera in a mode analogous to stepped frequency continuous wave (SFCW). Frequency coding uses techniques from radar to resolve multiple propagation paths. The minimal resolvable path length is dependent on the camera's modulation bandwidth and the spectrum estimation technique used to recover distance, and it is shown that SFCW can be used to measure depth of objects behind a translucent sheet, while AMCW measurements can not. Path lengths below quarter a wavelength of the highest modulation frequency are difficult to resolve. The use of spatial coding is used to resolve diffuse multi-path interference. The original technique comes from direct and global separation in computer graphics, and it is modified to operate on the complex data produced by a ToF range camera. By illuminating the scene with a pattern the illuminated areas contain the direct return and the scattering (global return). The non-illuminated regions contain the scattering return, assuming the global component is spatially smooth. The direct and global separation with sinusoidal patterns is combining with the sinusoidal modulation signal of ToF range cameras for a closed form solution to multi-path interference in nine frames. With nine raw frames it is possible to implement direct and global separation at video frame rates. The RMSE of a corner is reduced from 0.0952 m to 0.0112 m. Direct and global separation correctly measures the depth of a diffuse corner, and resolves subsurface scattering however fails to resolve specular reflections. Finally the direct and global separation is combined with replacing the illumination and reference signals with a binary sequence. The combination allows for resolving diffuse multi-path interference present in a corner, with the sparse multi-path interference caused mixed pixels between the foreground and background. The corner is correctly measured and the number of mixed pixels is reduced by 90%. With the development of new methods to resolve multi-path interference ToF range cameras can measure scenes with more confidence. ToF range cameras can be built into small form factors as they require a small number of parts: a pixel array, a light source and a lens. The small form factor coupled with accurate range measurements allows ToF range cameras to be embedded in cellphones and consumer electronic devices, enabling wider adoption and advantages over competing range imaging technologies
    corecore